http://www.tracopower.com Page 1 of 4
DC/DC Converters
TDR 3WI Series, 3 Watt
Features
Compact design in SMD or DIP package
Ultra wide 4:1 input voltage range
Fully regulated outputs
Low ripple and noise
No minimum load required
Temperature range –40°C to +85°C
I/O isolation 1500 VDC
Continuous short-circuit protection
Remote On/Off control
Fully RoHS compliant
3-year product warranty The TDR-3WI series is a family of compact 3 W dc/dc-converters with 4:1 input
voltage ranges and tightly regulated output voltages even under no load conditions.
The product is available in SMD-package or in DIP-package. They work with high
efficiency over the full load range and come with a remote On/Off input.
The usability in temperature ranges of up to +85°C, continuous short circuit protec-
tion and excellent immunity against environmental influences make these converters
very reliable.
A TDR-3WI converter is the ideal solution for space critical high end applications in
communication equipment, instrumentation and industrial electronics.
Order code
DIP models
Order code
SMD models Input voltage range Output voltage Output current
max. Efficiency typ.
TDR 3-1211WI TDR 3-1211WISM 5.0 VDC 600 mA 81 %
TDR 3-1212WI TDR 3-1212WISM 12 VDC 250 mA 82 %
TDR 3-1213WI TDR 3-1213WISM 4.5 – 18 VDC 15 VDC 200 mA 82 %
TDR 3-1222WI TDR 3-1222WISM (12 VDC nominal) ±12 VDC ±125 mA 82 %
TDR 3-1223WI TDR 3-1223WISM ±15 VDC ±100 mA 81 %
TDR 3-2411WI TDR 3-2411WISM 5.0 VDC 600 mA 80 %
TDR 3-2412WI TDR 3-2412WISM 12 VDC 250 mA 82 %
TDR 3-2413WI TDR 3-2413WISM 9 – 36 VDC 15 VDC 200 mA 82 %
TDR 3-2422WI TDR 3-2422WISM (24 VDC nominal) ±12 VDC ±125 mA 82 %
TDR 3-2423WI TDR 3-2423WISM ±15 VDC ±100 mA 81 %
TDR 3-4811WI TDR 3-4811WISM 5.0 VDC 600 mA 80 %
TDR 3-4812WI TDR 3-4812WISM 12 VDC 250 mA 83 %
TDR 3-4813WI TDR 3-4813WISM 18 – 75 VDC 15 VDC 200 mA 82 %
TDR 3-4822WI TDR 3-4822WISM (48 VDC nominal) ±12 VDC ±125 mA 82 %
TDR 3-4823WI TDR 3-4823WISM ±15 VDC ±100 mA 81 %
Models
UL 60950-1
http://www.tracopower.com Page 2 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TDR 3WI Series 3 Watt
Input Specifications
Input current at no load (nominal input voltage) 12 Vin models: 40 mA typ.
24 Vin models: 20 mA typ.
48 Vin models: 13 mA typ.
Input current at full load (nominal input voltage) 12 Vin models: 330 mA typ.
24 Vin models: 165 mA typ.
48 Vin models: 80 mA typ.
Surge voltage (1 sec. max.) 12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Input filter capacitor type (see EMC considerations page 3
for compliance to EN 55022 class A/B)
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3 10 V/m, perf. criteria A
Fast transient / Surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
with external input capacitor e.g. Nippon
chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Reflected ripple current 12 Vin models: 80 mAp-p typ.
(measured with input filter according class A) 24 Vin models: 40 mAp-p typ.
48 Vin models: 30 mAp-p typ.
Output Specifications
Voltage set accuracy ±1 % max
Regulation – Input variation Vin min. to Vin max. 0.2 % max.
– Load variation 0 – 100 % single output models: 1.0 % max.
dual output models: 1.0 % max. balanced load
– Load variation 10 – 90 % single output models: 0.5 % max.
dual output models: 0.8 % max. balanced load
– Load cross regulation 25/100 % 5.0 % max. (dual output models)
Minimum load 0 % of rated max. load
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz bandwidth) 30 mVp-p typ.
Start up time – Power On 5 ms typ.
(constant resistive load) – Remote On 5 ms typ.
Transient response setting time (25 % load step change) 250 µs typ.
Short circuit protection indefinite, automatic recovery
Capacitive load 5 VDC models: 1680 µF max.
12 VDC models: 820 µF max.
15 VDC models: 680 µF max.
±12 VDC models: ±470 µF max.
±15 VDC models: ±330 µF max.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Storage –55°C to +125°C
– Case temperature tba.
Load derating 3.3 %/K above +70°C
Humidity (non condensing) 5 % to 90 % rel. H max.
http://www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TDR 3WI Series 3 Watt
EMC Consideration
Recommended filter for
EN 55022 class A compliance
Input models C1 C3 L1
value
order code
(SMD type)
datasheet:
12 VDC 4.7 µF / 25 V 1812 MLCC 10 µH TCK-047 www.tracopower.com/products/tck047.pdf
24 VDC 4.7 µF / 50 V 1812 MLCC 220pF / 3 kV 1808 MLCC 12 µH TCK-062 www.tracopower.com/products/tck062.pdf
48 VDC 4.7 µF / 100 V 1812 MLCC 10 µH TCK-047 www.tracopower.com/products/tck047.pdf
General Specifications
Thermal shock acc. MIL-STD-810F
Vibration acc. MIL-STD-810F
Reliability, calculated MTBF (MIL-HDBK-217F, at+25°C, ground benign) >2.0 Mio h
Isolation voltage (60 sec.)Input/Output 1500 VDC
Isolation capacitance Input/Output 50 pF max.
Isolation resistance Input/Output (500 VDC) >10 GOhm
Altitude during operation tba.
Safety standard (designed to meet) IEC/EN 60950-1, UL 60950-1
Safety approvals – UL/cUL www.ul.com -> certifications -> File e188913
Switching frequency 100 kHz (PWM)
Remote On/Off On: open or high impedance
Off: 2...4 mA current applied via 1KOhm resistor
Off stand by input current 2.5 mA max.
Environmental compliance – Reach www.tracopower.com/products/tdr3wi-reach.pdf
– RoHS RoHS directive 2011/65/EU
TDR 3WI
dc/dc-converter
Load
L1
C1
C3
+Vin
-Vin
+Vout
-Vout
TDR 3WI
dc/dc-converter
Load
L1
C1 C2
C3
+Vin
-Vin
+Vout
-Vout
Input models C1 & C2 C3 L1
value
order code
(SMD type)
datasheet
12 VDC 6.8 µF / 25 V 1812 MLCC 10 µH TCK-047 www.tracopower.com/products/tck047.pdf
24 VDC 4.7 µF / 50 V 1812 MLCC 220pF / 3 kV 1808 MLCC 12 µH TCK-062 www.tracopower.com/products/tck062.pdf
48 VDC 4.7 µF / 100 V 1812 MLCC 18 µH TCK-046 www.tracopower.com/products/tck046.pdf
Recommended filter for
EN 55022 class B compliance
Page 4 of 4
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
DC/DC Converters
TDR 3WI Series 3 Watt
Outline Dimensions
Pin Single Dual
1–Vin (GND) –Vin (GND)
2Remote On/Off Remote On/Off
6NC Common
7NC –Vout
8+Vout +Vout
9–Vout Common
14 +Vin (Vcc) +Vin (Vcc)
Pin-Out
Rev. February 22. 2013
Dimensions in [mm], () = Inch
Tolerances: ±0.5 (±0.02)
Pin pich tolerances: ±0.25 (±0.01)
Pysical Specifications
Casing material non-conductive plastic (UL94V-0 rated)
Package weight 4.5 g ( 0.16 oz)
Soldering profile for DIP-package models max. 26C / 10 sec. (wave soldering)
Lead-free reflow solder process for SMD-package models as per J-STD-020D.01 (to find at:
www.jedec.org - free registration required)
Moisture sensivity level (for SMD-package models) level 2a as per J-STD-033B.01 (to find at:
www.jedec.org - free registration required)
Packaging – Tube 10 pcs packing unit
– Tape & Reel (only SMD models, add suffix –TR) 200 pcs packing unit
18.9
8.7
12.8
13.55
(0.74)
(0.35)
(0.533)
(0.50)
3.8
(0.15)
0.8(0.03)
1.3(0.05)
top view
14
9
8
1
2
6
7
2.542.54 10.161.8
(0.07) (0.1) (0.4) (0.1)
0.25 (0.01)
0-15°
2.542.54 10.161.8
18.9
8.7 12.8
17.2
(0.07) (0.1) (0.4)
(0.74)
(0.35)
(0.68)
(0.50)
(0.1)
1.0 (0.04)
1.5 (0.06)
top view
14
9
8
1
2
6
7
7.4 (0.29)
0.25 (0.01)
0-4°
1.2
(0.05)
DIP-Models
SMD-Models
NC = not to connect
Recommended Solder Pad
Dimension:
18.1 (0.71)
2.542.54 10.161.8
(0.07) (0.1) (0.4) (0.1)
1.8
(0.07)
2.0 (0.08)