http://www.tracopower.com Page 2 of 4
DC/DC Converters
THL 20WI Series 20 Watt
Input Specifications
Input current at no load – 24 Vin 3.3 VDC models: 80 mA typ.
(at nominal input voltage) 5.0 VDC models: 90 mA Typ.
all other models: 40 mA typ.
– 48 Vin 3.3 VDC models: 40 mA typ.
5.0 VDC models: 45 mA typ.
all other models: 25 mA typ.
Input current at full load – 24 Vin 3.3 VDC models: 700 mA typ.
(at nominal input voltage) other models: 940 mA typ..
– 48 Vin 3.3 VDC models: 350 mA typ.
other models: 470 mA typ.
Start-up voltage 24 V models: 9 VDC (or lower)
48 V models: 18 VDC (or lower)
Surge voltage (1 s max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reflected input ripple current 24 Vin models: 50 mAp-p typ.
48 Vin models: 30 mAp-p typ.
Conducted noise (input) EN 55032 class A, FCC part 15, level A
with external components (see application note)
ESD
(electrostatic discharge)
EN 61000-4-2, air ±8 kV, contact ±4 kV,
perf. criteria B
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Recommended input fuse (slow blow) 24 Vin models: 5000 mA
48 Vin models: 2500 mA
Output Specifications
Voltage set accuracy ±1 %
Output voltage adj. range ±10 % for single output models only
– For further information see application note www.tracopower.com/overview/thl20wi
Regulation – Input variation (Vmin – Vmax) single output models: 0.2 % max.
dual output models: 0.5 % max.
– Load variation single output models: 0.5 % max. (0 – 100 % load)
dual output models: 1.0 % max. (8 – 100 % balanced load)
Minimum load single output models: not required
dual output models: 8 % of rated max current
(operation at lower
load condition will not damage the converters.
However, they may not meet all listed specifications)
Ripple and noise (20 MHz bandwidth) 3.3 & 5.0 VDC models: 75 mVp-p typ.
12 & 15 VDC models: 100 mVp-p typ.
24 VDC models: 150 mVp-p typ.
Measured with a 1µF M/C and a 10µF T/C
Temperature coefficient ±0.02 %/K
Output current limitation at 150 % of Iout max., foldback
Short circuit protection indefinite, automatic recovery
Transient response setting time 300 µs typ. (25% load step change)
Max. capacitive load 3.3 VDC models: 10’300 µF
5 VDC models: 6’800 µF
12 VDC models: 1’200 µF
15 VDC models: 750 µF
24 VDC models: 300 µF
±12 VDC models: 680 µF (each output)
±15 VDC models: 380 µF (each output)