24
www.aemc.com
Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS
Three-Phase Power Quality Analyzer
Memory capacity of
2GB of trend data
storage: up to 50 screen
shots, 300 captured
transients/inrush and
10,000 alarm events
PowerPad® Model 8335
product includeS
Five 10 ft black voltage leads,
five black alligator clips, twelve
color-coded rings, USB cable,
NiMH battery, 110/240V power
adapter with US power cord,
DataView® software, large
classic tool bag, soft carrying
pouch and user manual.
(See page 25 for optional
current probes)
8335 Kit
3
3
W
A
R
R
A
N
T
Y
Y
E
A
R
(upon registering)
SpecificationS
MODEL 8335
ELECTRICAL
Sampling Frequency 256 samples/cycle
Data Storage 2GB SD Card for trend recording;
Additional separate 12.5MB partitioned for
snapshots, transients, Inrush & alarms
Voltage (TRMS) Phase-to-Phase: 2000V
Phase-to-Neutral: 1000V
Voltage Ratio: up to 500kV
Current (TRMS) MN Clamp: 0 to 6A/120A or 0 to 240A
SR Clamp: 0 to 1200A
MR Clamp: 0 to 1000Aac, 0 to 1400Adc
MiniFlex®: 10 to 1000A
AmpFlex®: 10 to 6500A(1)
Current Ratio: 10mA to 50kA
Frequency (Hz) 40 to 69Hz
Other Measurements kW, kVAR, kVA, PF, DPF, kWh, kVARh,
kVAh, K-Factor, Flicker
Harmonics 1st to 50th, Direction, Sequence
Power Source 9.6V NiMH rechargeable battery pack (included)
External AC supply: 110/230VAC ±10% (50/60Hz)
Battery Life ≥8 hours with display on; ≤35 hours with display off
(record mode)
MECHANICAL
Communication Port Optically isolated USB
Display ¼ VGA (320 x 240) color LCD display with adjustable
brightness & contrast
Dimensions 9.8 x 7.8 x 2.6" (250 x 200 x 67mm)
Weight 4.3 lbs (1.95kg)
Safety Rating EN 61010, 600V CAT IV(2), 1000V CAT III,
Pollution Degree 2
(1)Crest factor at 6500 = 1 (2)When used with SR193 or AmpFlex® probes.
600V CAT III with MN193 or MR193 probes.
Four voltage and four current inputs
R
A
T
I
N
G
S
A
F
E
T
Y
featureS
• Measurement of TRMS voltages up to 1000Vrms AC/DC
for two-, three-, four- or five-wire systems
• Measurement of TRMS currents up to 6500Arms
(sensor dependent)
• Color-coded input ID markers included
• Direct measurement of neutral current & voltage
• Frequency measurement (40 to 69Hz systems)
• Record and display trend data as fast as once
per second for one month for up to 25 variables
• Transient detection on all V and I inputs (up to 210)
• Selectable PT and CT ratios
• Inrush current measurement
• Calculation of Crest Factors for V and A
• Calculation of the K-Factor for transformers
• Calculation of short-term flicker
• Calculation of the Three-Phase voltage unbalance
• Harmonic measurements (referenced to the fundamental
or RMS value) for voltage, current or power, up to 50th
harmonic
• Displays of harmonic sequencing and
direction and calculation of overall harmonics
• Real-time display of Phasor diagrams
including values and phase angles
• Monitors the average value of any parameter,
calculated for a period from 1 sec to 2 hrs
• Measurement of active, reactive and apparent power per
phase and their respective sum total
• Calculation of power factor, displacement power factor
and tangent factor
• Recording, time stamping and characterization of
disturbance (swells, sags and interruptions, exceedence
of power and harmonic thresholds)
• 2GB internal Trend Recording memory; Alarm, Photo
and Transient Inrush memories are separate
• Measurement of energy VAh, VARh & Wh
• The Max and Min RMS measurements are
calculated every half-period
• Includes FREE DataView® software for data storage,
real-time display, analysis and report generation
• 65μs/sample trend recording