Features Regulated Converters * * * * * * 4:1 Wide Input Voltage Range 1.6kVDC Isolation UL, IEC/EN and EN50155 Certified Efficiency Up To 89% OVP, OCP & OTP +105C max Case Temperature Description The RPA30-AW series are high power density, wide input voltage range 30W DC/DC converters in an industry standard 1"x1" case size. Despite their small size, the RPA30-AW converters are fully specified devices with output currents up to 7.5Amps, up to 89% efficiency, no minimum load, 1600VDC isolation, tight regulation and low ripple/noise figures. The outputs are also fully protected against over-temperature, short circuits, overcurrent and overvoltage and the single output version offers a 10% trim range. A heatsink option is available to extend the operating temperature range. The converters are UL and EN50155 certified and will find many uses in railway and industrial applications where board space is at a premium. DC/DC Converter RPA30-AW 30 Watt 1"x1" Single & Dual Output Selection Guide Part Number Input Output Output Input(1)Efficiency(1) Max. Capacitive Voltage Range Voltage Current Current typ. Load [VDC] [VDC][mA][mA] [%] [F] RPA30-243.3SAW(2,3)9-36 3.3 75001172 88 10000 RPA30-2405SAW(2,3) 9-36 5 60001404 89 10000 RPA30-2412SAW(2,3) 9-36 12 25001420 88 1000 RPA30-2415SAW(2,3) 9-36 15 20001420 88 1000 RPA30-2412DAW(2,3) 9-36 12 12501420 88 1000 RPA30-2415DAW(2,3) 9-36 15 10001420 88 680 Notes: Note1: Tested at nominal Vin, full load and at +25C ambient E224736 UL60950-1 Certified IEC/EN60950 Certified EN50155 Certified Model Numbering RPA30-__ __ _AW/_ _ Input Voltage Output Voltage Package (3) CTRL Logic (2) Single or Dual Ordering Examples RPA30-243.3SAW = 24V Input, 3.3V Output, Single, no CTRL pin RPA30-2405SAW/P = 24V Input, 5V Output, Single, Pos. CTRL function RPA30-2415SAW-HC = 24V Input, 15V Output, Single, no CTRL pin, glued Heat-sink RPA30-2415DAW/N-HC = 24V Input, 15V Output, Dual, Neg. CTRL function, glued Heat-sink Notes: Note2: part without suffixes is without CTRL pin, trim pin fitted add suffix "P" for positive CTRL function (1=ON, 0=OFF), trim pin fitted add suffix "N" for negative CTRL function (0=ON, 1=OFF), trim pin fitted trim pin is only available for single outputs Note3: add suffix "-HC" for glued Heat-sink (compatible with all other suffixes) www.recom-power.com REV.: 5/2018 PD-1 RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 9VDC 24VDC 36VDC Internal Input Filter Pi-Type Input Voltage Range Input Surge Voltage 100ms max. 50VDC Quiescent Current Power up CTRL ON/OFF Start-up time 8ms Internal Operating Frequency 16ms 550kHz Minimum Load 0% Ripple and Noise 20MHz BW, 10F tantalum capacitor and 1F ceramic capacitor 50mVp-p DC-DC ON DC-DC OFF Under Voltage Lockout (UVLO) 8VDC 7VDC 8.5VDC 7.5VDC 9VDC 8VDC Positive Logic DC-DC ON DC-DC OFF Open or 2.4 < Vr < 10VDC Short or 0 < Vr < 0.8VDC Negative Logic DC-DC ON DC-DC OFF Short or 0 < Vr < 0.8VDC Open or 2.4 < Vr < 10VDC 6mA ON/OFF Control Input current of CTRL pin Output Voltage Trimming Single Outputs -10% +10% RPA30-243.3SAW Power Dissipation vs Output Current Efficiency vs. Output Current 100 90 70 Power Dissipation Efficiency [%] 80 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 0 10 20 30 40 50 60 70 80 90 100 6 5.5 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 9Vin 24Vin 36Vin 0 Output Current [%] 5.5 90 5 80 4.5 70 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 10 20 30 40 50 60 6 7.5 Power Dissipation vs Output Current Efficiency vs. Output Current 100 0 4.5 Output Current [A] Power Dissipation Efficiency [%] RPA30-2405SAW 3 1.5 70 80 90 4 3.5 3 2.5 2 1.5 9Vin 24Vin 36Vin 1 0.5 100 Output Current [%] 0 0 1 2 3 4 5 6 Output Current [A] continued on next page PD-2 REV.: 5/2018 www.recom-power.com RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted RPA30-2412SAW Efficiency vs. Output Current Power Dissipation vs Output Current 5.5 90 5 80 4.5 70 Power Dissipation Efficiency [%] 100 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 0 10 20 30 40 50 60 70 80 4 3.5 3 2.5 2 1.5 9Vin 24Vin 36Vin 1 0.5 90 0 100 0 0.5 Output Current [%] RPA30-2415SAW Efficiency vs. Output Current 5 80 4.5 70 Power Dissipation Efficiency [%] 2.5 Power Dissipation vs Output Current 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 10 20 30 40 50 60 70 80 90 4 3.5 3 2.5 2 1.5 9Vin 24Vin 36Vin 1 0.5 0 100 0 0.4 Output Current [%] RPA30-2412DAW 0.8 1.2 1.6 2 Output Current [A] Efficiency vs. Output Current Power Dissipation vs Output Current 100 5.5 90 5 80 4.5 70 4 Power Dissipation Efficiency [%] 2 5.5 90 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 1.5 Output Current [A] 100 0 1 0 10 20 30 40 50 60 70 80 90 3.5 3 2.5 2 1.5 9Vin 24Vin 36Vin 1 0.5 100 Output Current [%] 0 0 0.25 0.5 0.75 1 1.25 Output Current [A] continued on next page www.recom-power.com REV.: 5/2018 PD-3 RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted RPA30-2415DAW Efficiency vs. Output Current Power Dissipation vs Output Current 100 5.2 90 4.4 70 Power Dissipation Efficiency [%] 80 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 0 10 20 30 40 50 60 70 80 90 3.6 2.8 2.0 0.4 0 100 9Vin 24Vin 36Vin 1.2 0 0.2 Output Current [%] 0.4 0.6 0.8 1 Output Current [A] OUTPUT TRIM Output Voltage Trimming RPA30-AW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary. TRIM DOWN TRIM UP 5 5 RU RD 6 4 RPA30-243.3SAW Trim up 1 2 3 4 5 6 7 8 9 10 Vout = 3.33 3.36 3.39 3.43 3.46 3.49 3.53 3.56 3.59 3.63 Volts RU = 402 169 100 75 47.5 34.8 26.1 17.8 12.1 8.06 kOhms Trim down % 1 2 3 4 5 6 7 8 9 10 Vout = 3.27 3.23 3.20 3.17 3.14 3.10 3.07 3.04 3.0 2.97 % Volts RD = 402 191 113 75 52.3 39.2 26.7 20 12.1 8.06 kOhms 4 5 6 7 8 9 10 RPA30-2405SAW Trim up 1 2 3 Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.40 5.45 5.50 Volts RU = 604 243 147 95.3 68.1 39.2 34.8 22.1 15 8.06 kOhms 1 2 3 4 5 6 7 8 9 10 Vout = 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 Volts RD = 604 287 169 124 105 78.7 54.9 39.2 15 0.5 kOhms % Trim down % % RPA30-2412SAW Trim up 1 2 3 4 5 6 7 8 9 10 Vout = 12.12 12.24 12.36 12.48 12.6 12.72 12.84 12.96 13.08 13.20 604 267 162 105 75 499 40.2 24.9 18.2 10 kOhms 1 2 3 4 5 6 7 8 9 10 % 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.80 Volts 750 309 200 124 90.9 64.9 45.3 32.4 20 12.1 kOhms RU = Trim down Vout = RD = Volts continued on next page PD-4 REV.: 5/2018 www.recom-power.com RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted RPA30-2415SAW Trim up 1 2 3 4 5 6 7 8 9 10 Vout = 15.15 15.30 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 RU = 1000 243 200 130 90.9 61.9 40.2 30.1 24.9 10 kOhms % Trim down % Volts 1 2 3 4 5 6 7 8 9 10 Vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 13.65 13.50 Volts RD = 1000 348 210 140 95.3 68.1 45.3 30.1 18.2 8.06 kOhms REGULATION Parameter Condition Output Accuracy Line Regulation Value Single & Dual 2.0% max. Single low line to high line Dual 0.2% max. 0.5% max. Load Regulation 3.3Vout 5Vout 12Vout, 15Vout 12Vout, 15Vout Cross Regulation asymmetrical 25%<>100% load 0.3% 0.2% 0.1% 1.0% 3.0% max. 50-75%, full load, 0.1A/s Transient Response 3.0% Vout typ. 25% load step change 250s typ. PROTECTION Parameter Condition Short Circuit Protection (SCP) below 100m Value continuous, auto recovery Over Voltage Protection (OVP) 115%-150% Output Voltage, Hiccup, auto recovery Over Current Protection (OCP) 110%-160% Output Current, Hiccup Over Temperature Protection (OTP) +115C 5C I/P to O/P Isolation Voltage (5) Isolation Resistance tested for 1 minute 1.6kVDC 10M min. Isolation Capacitance 1100pF typ. Insulation Grade basic Notes: Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: 4A slow blow type. Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage. ENVIRONMENTAL Parameter Operating Temperature Range Condition Maximum Case Temperature +105C Temperature Coefficient 0.02%/C Thermal Impedance please refer to table 1 Operating Altitude 2000m Operating Humidity 95% RH Shock 5G, 30ms, 6 times along X,Y and Z axis Vibration MTBF Value -40C to [refer to thermal calculation] (6) 10-500Hz, 2.4G, 30mins along X,Y and Z axis according to Telcordia SR332 3, +25C 5888 x 103 hours continued on next page www.recom-power.com REV.: 5/2018 PD-5 RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted Table 1: Thermal Impedance without Heatsink airflow [m/s] 0.1 0.2 0.5 1.0 1.5 2.0 with Heatsink Rth without PCB Rth with PCB [C/W] [C/W] 17.8 12.5 16.0 11.2 14.0 9.7 10.0 7.1 8.3 5.8 6.3 4.4 (6) Rth without PCB Rth with PCB (6) [C/W] [C/W] Notes: Note6: Test PCB:160x100mm105m (Eurocard), double layer 16.0 11.3 14.4 10.1 12.6 8.7 9.0 6.4 7.5 5.2 5.7 4.0 Thermal Calculation choose your model: RPA30-2405SAW (with PCB (6) ) * Load conditions in application (e.g. 50%) * Airflow conditions in application (e.g. 0.5m/s) * use Rth from Table1 (9.7C/W) choose your model: Calculation: RPA30-2405SAW-HC (with PCB (6) ) * Load conditions in application (e.g. 50%) * Airflow conditions in application (e.g. 0.5m/s) * use Rth from Table1 (8.7C/W) Calculation: Iout = 50% Rth = 9.7C/W = 2.2W PDISS[C] Ambient Temperature TCASEmax = 105C Iout = 50% Rth = 8.7C/W PDISS = 2.2W Ambient Temperature [C] TCASEmax = 105C TOVER=Rth x PDis = 9.7C/W x 2.2W = 21.3C TOVER=Rth x PDis = 8.7C/W x 2.2W = 19.1C TAMBmax =TCASEmax - TOVER = 105C - 21.3C = 83.7C TAMBmax =TCASEmax - TOVER = 105C - 19.1C = 85.9C RPA30-2405SAW-HC 100 100 90 90 80 80 70 70 Output Power [%] Output Power [%] RPA30-2405SAW 60 50 40 30 20 10 0 -40 Nature Convection (0.1m/s) 0.2m/s 0.5m/s 1.0m/s 1.5m/s 2.0m/s 20 40 60 50 40 30 20 10 60 80 83.7 0 -40 100 110 Nature Convection (0.1m/s) 0.2m/s 0.5m/s 1.0m/s 1.5m/s 2.0m/s 20 Ambient Temperature [C] 40 60 80 85.9 100 110 Ambient Temperature [C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment, General Requirements for Safety E224736-A39 + A40 IEC/EN Information Technology Equipment - General Requirments for Safety (CB Scheme) E224736-A39-CB + A40-CB Railway Applications - Electrical Equipment used on rolling stock 15100175 001, 15100176 001 Standard UL60950-1, 2nd Edition, 2014 CSA C22.2 No. 60950, 2nd Edition, 2014 IEC60950-1, 2nd Edition, 2005 + AM2, 2013 EN60950-1, 1st Edition, 2006 + AM2, 2013 EN50155, 1st Edition, 2007, Clause 5.4 and 5.5 RoHS 10/10, 2011/65/EU + AM-2015/863 RoHs 2+ continued on next page PD-6 REV.: 5/2018 www.recom-power.com RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted EMC Compliance (designed to meet) Information technology equipment- Radio disturbance characteristicsLimits and methods of measurement Condition Standard / Criterion with external filter EN55022, Class A, 2010 Railway applications - Electromagnetic compatibility Part 3-2: Rolling stock - Apparatus Specification for radio disturbance and immunity measuring apparatus and methods Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements Specification for radio disturbance and immunity measuring apparatus and methods Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements EN50121-3-2, 2015 EN55016-2-1, 2009 EN55016-2-3, 2010 ESD Electrostatic discharge immunity test Air 8kV, Contact 6kV EN61000-4-2, 2009; Criteria A 20V/m, 80-1000MHz 10V/m, 1.4-2.0GHz 5V/m, 2.0-2.7GHz 3V/m, 5.1-6.0GHz EN61000-4-3, 2006; Criteria A Fast Transient and Burst Immunity 2kV IEC61000-4-4, 2004; Criteria A Surge Immunity 1kV EN61000-4-5, 2006; Criteria A Immunity to conducted disturbances, induced by radio-frequency fields 10V EN61000-4-6, 2009; Criteria A Radiated, radio-frequency, electromagnetic field immunity test EMI Filtering according to EN50121-3-2 and EN55022 Class A 7 C1 LOAD D1 LOAD +VIN L1 Fuse -VIN Notes: Note7: Diode is only needed for EN50155. C1 L1 47F/50V electrolytic capacitor 1H Choke DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Material Package Dimensions (LxWxH) Package Weight Type Value Case Baseplate Potting without Heat-sink with Heat-sink Al Alloy, anodize black non-conductive FR4 Silicone 25.4 x 25.4 x 10.2mm 25.4 x 25.4 x 16.8mm without Heat-sink with Heat-sink 17g typ. 21g typ. continued next page www.recom-power.com REV.: 5/2018 PD-7 16.8 RPA30-AW DC/DC Converter Series 25.4 Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted Dimension Drawing (mm) 10.2 25.4 6.0 O 1.0 recommended Layout: Top View 2.54 20.32 3 2.54 5 2 1 4 5 12.7 2 10.16 2.54 1 Bottom View 3 10.16 25.4 5.08 6 6 x O1.5 6 4 Pin Connections Pin # Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 CTRL CTRL(2) 4 -Vout Heat-sink Dimension Drawing (mm) 25.4 Top View Heat-sink (2) -Vout 5 Trim Com 6 +Vout +Vout Pin Pitch Tolerance 0.25mm Pin dimension tolerance 0.1mm XX.X 0.5mm XX.XX 0.25mm 16.8 25.4 25.4 PD-8 REV.: 5/2018 25.4 www.recom-power.com RPA30-AW DC/DC Converter Series Specifications measured @ta = 25C, resistive load, nominal Vin and rated Iout unless otherwise noted PACKAGING INFORMATION Parameter Packaging Dimensions (LxWxH) Type without Heat-sink with Heat-sink Packaging Quantity Value tube 285.0 x 27.6 x 19.0mm 285.0 x 27.6 x 25.8mm 10pcs Storage Temperature Range -55C to +125C Storage Humidity 5% - 95% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 5/2018 PD-9