a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 e www.allsensors.com all sensors
All Sensors DS-0368 Rev A
Pinout:
Pin 1: Vs
Pin 2: Gnd
Pin 3: Vout
Pin 4: Do Not Connect
The ADCA series of Amplified low pressure sensors are based upon a proprietary technology to reduce all output offset or common
mode errors. This model provides a ratiometric 4-volt output with superior output offset characteristics. Output offset errors due to
change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all significantly reduced when
compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration en-
hanced structure to provide a very linear output to measured pressure.
These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series
is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts.
0.25 to 60 In H2O Pressure Ranges
Ratiometric 4V Amplified Output
Temperature Compensated Ranges Available in Standard,
Industrial and Military ranges.
Calibrated Zero and Span
Physical Dimensions
Medical Instrumentation
Environmental Controls
HVAC
General Description
Applications
Features
ADCA Series Amplified Low Pressure Sensors
-
+
Vs
Vout
Gnd
Equivalent Circuit
Pin 1 Identifier
C
L
Port A
Port B
0.020" x 0.010" Pin
0.30" minimum length
21.59
0.850
20.32
0.800
27.43
1.080
10.67
0.420
10.67
0.420
2.54
0.125R
3.18
0.140
3.56
(Typ)
0.1000.050
1.27
0.210
5.33
Port 0.179"/0.189"
0.550
13.97
0.480
12.19
3.18
0.125
0.344
8.74
Page 1
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
ADCA Series Amplified Low Pressure Sensors
Standard Pressure Ranges
Supply Voltage VS
Common-mode pressure
Lead Temperature, max
(soldering 2-4 sec.)
+4.5 to +5.5 Vdc
-10 to +10 psig
270°C
Pressure Sensor Ratings
Temperature Ranges
Compensated
Operating & Storage
Humidity Limits
Standard: 5° C to 50° C
Industrial: -25° C to 85° C
Military: -40° C to 125° C
-40 to 125° C
0 to 95% RH
(non condensing)
Environmental Specifications
Ordering Information:
Page 2
5 INCH - D - 4V
Pressure Range Pressure
Type
Amplified
4V
Output
Where:
Compensation Temperature Range: ___________ (empty indicates Standard)
Compensation Temperature Range: “—PRIME” indicates Industrial
Compensation Temperature Range: “—MIL indicates Military
Example: 5 INCH-D-4V-PRIME
Compensation
Temperature
Range:
Device Pressure Type Nominal Span
Specification
Notes
inH2O Pa inH2O kPa inH2O kPa
0.25 INCH-D-4V ±0.25 65 Differential 4V 40 10 80 20 1
0.25 INCH-G-4V 0 to 0.25 65 Gage 4V 40 10 80 20 1
0.5 INCH-D-4V ±0.5 125 Differential 4V 40 10 80 20 1
0.5 INCH-G-4V 0 to 0.5 125 Gage 4V 40 10 80 20 1
1 MBAR-D-4V ±1 mbar 100 Differential 4V 100 25 200 50 1
1 INCH-D-4V ±1 250 Differential 4V 100 25 200 50
1 INCH-G-4V 0 to 1 250 Gage 4V 100 25 200 50
2.5 INCH-D-4V ±2.5 625 Differential 4V 200 50 300 75 1
2.5 INCH-G-4V 0 to 2.5 625 Gage 4V 200 50 300 75 1
5 INCH-D-4V ±5 1,250 Differential 4V 200 50 300 75
5 INCH-G-4V 0 to 5 1,250 Gage 4V 200 50 300 75
10 INCH-D-4V ±10 2,500 Differential 4V 200 50 300 75
10 INCH-G-4V 0 to 10 2,500 Gage 4V 200 50 300 75
20 INCH-D-4V ±20 5,000 Differential 4V 300 75 500 125
20 INCH-G-4V 0 to 20 5,000 Gage 4V 300 75 500 125
30 INCH-D-4V ±30 7,500 Differential 4V 500 125 800 200
30 INCH-G-4V 0 to 30 7,500 Gage 4V 500 125 800 200
40 INCH-G-4V 0 to 40 10,000 Gage 4V 500 125 800 200 1
60 INCH-G-4V 0 to 60 15,000 Gage 4V 500 125 800 200 1
Operating Range A, B Proof Pressure Burst Pressure
Note A: Operating range in Pa is expressed as an approximate value.
Note B: Products are calibrated to operating range expressed in inH2O (except 1 MBAR-D-4V, which is calibrated to range in mbar).
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 e www.allsensors.com all sensors
All Sensors DS-0368 Rev A
Performance Characteristics for ADCA Series Amplified Low Pressure Sensors
Parameter Minimum Nominal Maximum Units Specification
Notes
Output Span
All Differential Products ±1.90 ±2.0 ±2.10 V 5
All Gage Products 3.9 4.0 4.1 V 5
Span Temperature Shift
0.25 INCH-D-4V - - ±3 %FSS 2
0.25 INCH-G-4V - - ±3 %FSS 2
0.50 INCH-D-4V - - ±3 %FSS 2
0.50 INCH-G-4V - - ±3 %FSS 2
1 MBAR-D-4V - - ±3 %FSS 2
1 INCH-D-4V - - ±2 %FSS 2
1 INCH-G-4V - - ±2 %FSS 2
2.5 INCH-D-4V - - ±2 %FSS 2
2.5 INCH-G-4V - - ±2 %FSS 2
All Others - - ±1 %FSS 2
Offset Voltage @ zero differential pressure
All Differential Products 2.15 2.25 2.35 V -
All Gage Products 0.15 0.25 0.35 V -
Offset Temperature Shift
0.25 INCH-D-4V - - ±60 mV 2
0.25 INCH-G-4V - - ±60 mV 2
0.50 INCH-D-4V - - ±60 mV 2
0.50 INCH-G-4V - - ±60 mV 2
1 MBAR-D-4V - - ±60 mV 2
1 INCH-D-4V - - ±60 mV 2
1 INCH-G-4V - - ±60 mV 2
2.5 INCH-D-4V - - ±60 mV 2
2.5 INCH-G-4V - - ±60 mV 2
5 INCH-D-4V - - ±40 mV 2
5 INCH-G-4V - - ±40 mV 2
All Others - - ±20 mV 2
Offset Warm-up Shift
0.25 INCH-D-4V - ±20 - mV 3
0.25 INCH-G-4V - ±20 - mV 3
0.50 INCH-D-4V - ±20 - mV 3
0.50 INCH-G-4V - ±20 - mV 3
1 MBAR-D-4V - ±20 - mV 3
1 INCH-D-4V - ±10 - mV 3
1 INCH-G-4V - ±10 - mV 3
All Others - ±5 - mV 3
Offset Position Sensitivity (±1g)
0.25 INCH-D-4V -±20 - mV 6
0.25 INCH-G-4V -±20 - mV 6
0.50 INCH-D-4V -±20 - mV 6
0.50 INCH-G-4V -±20 - mV 6
1 MBAR-D-4V -±20 - mV 6
1 INCH-G-4V - ±15 - mV 6
All Others - ±5 - mV 6
Offset Long Term Drift (one year)
0.25 INCH-D-4V - ±20 - mV -
0.25 INCH-G-4V - ±20 - mV -
0.50 INCH-D-4V - ±20 - mV -
0.50 INCH-G-4V - ±20 - mV -
1 INCH-D-4V - ±10 - mV -
1 INCH-G-4V - ±10 - mV -
All Others - ±5 - mV -
Linearity, Hysteresis error (all products) - 0.05 0.25 %FSS 4
Specification Notes
Note 1: Part number is available in Standard Compensation Temperature Range only.
Note 3: Shift is within the first hour of excitation applied to the device.
Note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
Note 5: The span is the algebraic difference between full scale output voltage and the offset voltage.
Note 6: Parameter is characterized and not 100% tested.
All parameters are measured at 5.0 volt excitation and room temperature unless otherwise specified. Pressure
measurements are with positive pressure applied to PORT B
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 500 useconds.
Note 2: Shift is relative to 25°C between standard, industrial, or military compensated temperature
range endpoints.
Page 3
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
ADCA Series Amplified Low Pressure Sensors
Page 4
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit
described herein, neither does it convey any license under its patent rights nor the rights of others.
Performance Characteristics for ADCA Series Amplified Low Pressure Sensors (Cont'd)
Parameter Minimum Nominal Maximum Units Specification
Notes
Offset Long Term Drift (one year)
0.25 INCH-D-4V - ±20 - mV -
0.25 INCH-G-4V - ±20 - mV -
0.50 INCH-D-4V - ±20 - mV -
0.50 INCH-G-4V - ±20 - mV -
1 MBAR-D-4V -±20 - mV -
1 INCH-D-4V - ±10 - mV -
1 INCH-G-4V - ±10 - mV -
All Others - ±5 - mV -
Linearity, Hysteresis error (all products) - 0.05 0.25 %FSS 4
Specification Notes
Note 1: Part number is available in Standard Compensation Temperature Range only.
Note 3: Shift is within the first hour of excitation applied to the device.
Note 4: Measured at one-half full scale rated pressure using best straight line curve fit.
Note 5: The span is the algebraic difference between full scale output voltage and the offset voltage.
Note 6: Parameter is characterized and not 100% tested.
All parameters are measured at 5.0 volt excitation and room temperature unless otherwise specified. Pressure
measurements are with positive pressure applied to PORT B
Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less
than 500 useconds.
Note 2: Shift is relative to 25°C between standard, industrial, or military compensated temperature
range endpoints.
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R