ADCA Series Amplified Low Pressure Sensors
Standard Pressure Ranges
Supply Voltage VS
Common-mode pressure
Lead Temperature, max
(soldering 2-4 sec.)
+4.5 to +5.5 Vdc
-10 to +10 psig
270°C
Pressure Sensor Ratings
Temperature Ranges
Compensated
Operating & Storage
Humidity Limits
Standard: 5° C to 50° C
Industrial: -25° C to 85° C
Military: -40° C to 125° C
-40 to 125° C
0 to 95% RH
(non condensing)
Environmental Specifications
Ordering Information:
Page 2
5 INCH - D - 4V
Pressure Range Pressure
Type
Amplified
4V
Output
Where:
Compensation Temperature Range: ___________ (empty – indicates Standard)
Compensation Temperature Range: “—PRIME” indicates Industrial
Compensation Temperature Range: “—MIL” indicates Military
Example: 5 INCH-D-4V-PRIME
Compensation
Temperature
Range:
Device Pressure Type Nominal Span
Specification
Notes
inH2O Pa inH2O kPa inH2O kPa
0.25 INCH-D-4V ±0.25 65 Differential 4V 40 10 80 20 1
0.25 INCH-G-4V 0 to 0.25 65 Gage 4V 40 10 80 20 1
0.5 INCH-D-4V ±0.5 125 Differential 4V 40 10 80 20 1
0.5 INCH-G-4V 0 to 0.5 125 Gage 4V 40 10 80 20 1
1 MBAR-D-4V ±1 mbar 100 Differential 4V 100 25 200 50 1
1 INCH-D-4V ±1 250 Differential 4V 100 25 200 50 –
1 INCH-G-4V 0 to 1 250 Gage 4V 100 25 200 50 –
2.5 INCH-D-4V ±2.5 625 Differential 4V 200 50 300 75 1
2.5 INCH-G-4V 0 to 2.5 625 Gage 4V 200 50 300 75 1
5 INCH-D-4V ±5 1,250 Differential 4V 200 50 300 75 –
5 INCH-G-4V 0 to 5 1,250 Gage 4V 200 50 300 75 –
10 INCH-D-4V ±10 2,500 Differential 4V 200 50 300 75 –
10 INCH-G-4V 0 to 10 2,500 Gage 4V 200 50 300 75 –
20 INCH-D-4V ±20 5,000 Differential 4V 300 75 500 125 –
20 INCH-G-4V 0 to 20 5,000 Gage 4V 300 75 500 125 –
30 INCH-D-4V ±30 7,500 Differential 4V 500 125 800 200 –
30 INCH-G-4V 0 to 30 7,500 Gage 4V 500 125 800 200 –
40 INCH-G-4V 0 to 40 10,000 Gage 4V 500 125 800 200 1
60 INCH-G-4V 0 to 60 15,000 Gage 4V 500 125 800 200 1
Operating Range A, B Proof Pressure Burst Pressure
Note A: Operating range in Pa is expressed as an approximate value.
Note B: Products are calibrated to operating range expressed in inH2O (except 1 MBAR-D-4V, which is calibrated to range in mbar).
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R
www.allsensors.com
Signed Original On File
R