Part Number: 2412
DataTwist 2400 Cat 6+ Cable, U/UTP, PVC, 4 Pair, AWG 23, Riser
Product Description
CAT6+ (350MHz), 4-Pair, U/UTP-unshielded, Riser-CMR, Premise Horizontal cable, 23 AWG solid bare copper conductors, polyolefin insulation, tape
separator, ripcord, PVC jacket
Technical Specifications
Product Overview
Environmental Space: Riser
Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM
Physical Characteristics (Overall)
Conductor
AWG Stranding Material No. of Pairs
23 Solid BC - Bare Copper 4
Conductor Count: 8
Total Number of Pairs: 4
Conductor Size: 23 AWG
Insulation
Material
PO - Polyolefin
Bonded-Pair: N/A
Color Chart
Number Color
1White/Blue Stripe & Blue
2White/Orange Stripe & Orange
3White/Green Stripe & Green
4White/Brown Stripe & Brown
Outer Jacket Material
Material Nominal Diameter Ripcord Separator Material
PVC - Polyvinyl Chloride 0.224 in Yes Patented Dielectric Tape
Electrical Characteristics
Conductor DCR
Max. Conductor DCR Max. DCR Unbalance
78 Ohm/km 3 %
Capacitance
Max. Capacitance Unbalance Nom.Mutual Capacitance
330 pF/100m 17 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 35 ns/100m 70 %
High Freq
Frequency
[MHz]
Max. Insertion Loss
(Attenuation)
Min.
NEXT [dB]
Min.
PSNEXT [dB]
Min.
ACR [dB]
Min.
PSACR [dB]
Min. ACRF
(ELFEXT) [dB]
Min. PSACRF
(PSELFEXT) [dB]
Min. RL (Return
Loss) [dB]
Max./Min. Input
Impedance (unFitted)
Max./Min. Fitted
Impedance
1 MHz 2.0 dB/100m 75.3 dB 75.3 dB 73.3 dB 73.3 dB 70.8 dB 67.8 dB 20.0 dB 100 ± 15 Ohm 102 ± 15 Ohm
4 MHz 3.7 dB/100m 66.3 dB 66.3 dB 62.6 dB 62.6 dB 58.8 dB 55.8 dB 23.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
8 MHz 5.2 dB/100m 61.8 dB 61.8 dB 56.6 dB 56.6 dB 52.7 dB 49.7 dB 24.5 dB 100 ± 15 Ohm 100 ± 15 Ohm
10 MHz 5.8 dB/100m 60.3 dB 60.3 dB 54.5 dB 54.5 dB 50.8 dB 47.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
16 MHz 7.4 dB/100m 57.2 dB 57.2 dB 49.9 dB 49.9 dB 46.7 dB 43.7 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
20 MHz 8.3 dB/100m 55.8 dB 55.8 dB 47.5 dB 47.5 dB 44.8 dB 41.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
25 MHz 9.3 dB/100m 54.3 dB 54.3 dB 45.1 dB 45.1 dB 42.8 dB 39.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 15 Ohm
31.25 MHz 10.4 dB/100m 52.9 dB 52.9 dB 42.5 dB 42.5 dB 40.9 dB 37.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 15 Ohm
62.5 MHz 15.0 dB/100m 48.4 dB 48.4 dB 33.4 dB 33.4 dB 34.9 dB 31.9 dB 21.5 dB 100 ± 15 Ohm 100 ± 15 Ohm
100 MHz 19.3 dB/100m 45.3 dB 45.3 dB 26.0 dB 26.0 dB 30.8 dB 27.8 dB 20.8 dB 100 ± 15 Ohm 100 ± 15 Ohm
155 MHz 24.6 dB/100m 42.4 dB 42.4 dB 17.9 dB 17.9 dB 27.0 dB 24.0 dB 19.5 dB 100 ± 22 Ohm 100 ± 15 Ohm
200 MHz 28.3 dB/100m 40.8 dB 40.8 dB 12.5 dB 12.5 dB 24.8 dB 21.8 dB 18.7 dB 100 ± 22 Ohm 100 ± 15 Ohm
250 MHz 32.1 dB/100m 39.3 dB 39.3 dB 7.2 dB 7.2 dB 22.8 dB 19.8 dB 18.0 dB 100 ± 32 Ohm 100 ± 15 Ohm
300 MHz 35.6 dB/100m 38.1 dB 36.1 dB 2.5 dB 0.5 dB 21.3 dB 18.3 dB 17.5 dB 100 ± 32 Ohm 100 ± 15 Ohm
350 MHz 38.9 dB/100m 37.1 dB 35.1 dB -1.8 dB -3.8 dB 19.9 dB 16.9 dB 17.0 dB 100 ± 32 Ohm 100 ± 15 Ohm
400 MHz 42.0 dB/100m 36.3 dB 34.3 dB -5.7 dB -7.7 dB 18.8 dB 15.8 dB 16.6 dB 100 ± 32 Ohm 100 ± 15 Ohm
450 MHz 45.0 dB/100m 35.5 dB 33.5 dB -9.5 dB -11.5 dB 17.7 dB 14.7 dB 16.2 dB 100 ± 32 Ohm 100 ± 15 Ohm
500 MHz 47.9 dB/100m 34.8 dB 32.8 dB -13.1 dB -15.1 dB 16.8 dB 13.8 dB 15.9 dB 100 ± 32 Ohm 100 ± 15 Ohm
550 MHz 50.6 dB/100m 34.2 dB 32.2 dB -16.4 dB -18.4 dB 16.0 dB 13.0 dB 15.6 dB 100 ± 32 Ohm 100 ± 15 Ohm
Voltage
UL Voltage Rating
300 V RMS
Temperature Range
Installation Temp Range: 0°C To +50°C
UL Temp Rating: 75°C
Storage Temp Range: -20°C To +75°C
Operating Temp Range: -20°C To +75°C
Mechanical Characteristics
Bulk Cable Weight: 22 lbs/1000ft
Max Recommended Pulling Tension: 25 lbs
Min Bend Radius During Installation: 2.25 in
Min Bend Radius/Minor Axis: 1.0 in
Standards
NEC Articles: 800
NEC/(UL) Specification: CMR
CEC/C(UL) Specification: CMR
ISO/IEC Compliance: 11801 ed 2.2 (2011) Class E
CPR Euroclass: Eca
Data Category: Category 6
ANSI Compliance: S-116-732-2013 Category 6, ANSI/NEMA WC-66 Category 6
Telecommunications Standards: ANSI/TIA-568-C.2 Category 6
IEEE Specification: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Third Party Performance Verification: Category 6
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU: Yes
EU Directive Compliance: Yes
EU CE Mark: Yes
EU REACH SVHC Compliance (yyyy-mm-dd): 2017-07-10
EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Aerial: No
Suitability - Burial: No
Suitability - Hazardous Locations: No
Suitability - Indoor: Yes
Suitability - Non-Halogenated: No
Suitability - Oil Resistance: No
Suitability - Outdoor: No
Suitability - Sunlight Resistance: No
Flammability, LS0H, Toxicity Testing
C(UL) Flammability: FT4
UL Flammability: UL 1666 Riser
CSA Flammability: CMR FT 4
ISO/IEC Flammability: IEC 60332-1-2
UL voltage rating: 300 V RMS
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 2413
Part Number
Variants
Item # Color UPC Length Footnote
2412 0101000 Black 612825061199 1,000 ft
2412 010A1000 Black 612825061205 1,000 ft
2412 010U1000 Black 612825062165 1,000 ft
2412 0061000 Blue 612825061045 1,000 ft
2412 0061400 Blue 612825061076 1,400 ft
2412 0062500 Blue 612825061069 2,500 ft
2412 0065000 Blue 612825062134 5,000 ft C
2412 006A1000 Blue 612825061052 1,000 ft
2412 006U1000 Blue 612825061236 1,000 ft
2412 0081000 Gray 612825061168 1,000 ft
2412 008A1000 Gray 612825061175 1,000 ft
2412 008U1000 Gray 612825061243 1,000 ft
2412 0051000 Green 612825061083 1,000 ft
2412 005A1000 Green 612825061090 1,000 ft
2412 005U1000 Green 612825062127 1,000 ft
2412 003A1000 Orange 612825061212 1,000 ft
2412 003U1000 Orange 612825062103 1,000 ft
2412 007A1000 Purple 612825061182 1,000 ft
2412 007U1000 Purple 612825062141 1,000 ft
2412 002A1000 Red 612825061229 1,000 ft C
2412 0091000 White 612825061106 1,000 ft
2412 0092500 White 612825061120 2,500 ft
2412 0095000 White 612825062158 5,000 ft C
2412 009A1000 White 612825061113 1,000 ft
2412 009U1000 White 612825061250 1,000 ft
2412 0041000 Yellow 612825061137 1,000 ft
2412 0042500 Yellow 612825061144 2,500 ft
2412 004A1000 Yellow 612825061151 1,000 ft
2412 004U1000 Yellow 612825062110 1,000 ft
Footnote: C - CRATE REEL PUT-UP.
Patent: https://www.belden.com/resources/patents
Product Notes
Notes: Values above 350 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.
History
Update and Revision: Revision Number: 0.445 Revision Date: 07-11-2019
© 2019 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.