10 Watts Total Power: Input Voltages: No. of Outputs: 10 Watts 12V Single and Dual AEE00-12Vin Electrical Specs Input Input range 9 to 18 VDC Efficiency 78% typical (3.3V) Output Special Features * * * * * * 10 W, Dual output 2:1 Input range 1.0" x 2.0" x 0.33 case Industry standard package Low Profile Low Cost Voltage tolerance Overall regulation Noise/ripple Transient response 1.0% 1% max 1% Typ, 2% Max 300 usec typical (50% step load change to within 3%Vo) Temperature Regulation 0.02 %Vo/C Switching frequency 330kHz Isolation I/O isolation 1500 VDC Input to Output 1000 VDC Input to Case 1000 VDC Output to Case Isolation Resistance 300 Mohms Environmental Operating base temperature range: -25C to +100C Storage temperature: -40C to +125C MTBF: 3 Million Hours (Belcore TR332) Safety 2 UL UL1950 Recognition CSA CSA22.2-950 Recognition TUV EN60950 Recognition North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-9662 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Ordering Information Input Voltage Output Voltage Efficiency Model Number 9-18 V 9-18 V 9-18 V 9-18 V 3.3V @ 2.55 A 5.0V @ 2 A 12V @ 0.84 A 15V @ 0.68 A 78% 81% 83% 84% AEE02F12-49 AEE02A12-49 AEE00B12-49 AEE00C12-49 9-18 V 9-18 V 9-18 V 5V @ 1.0 A 12V @ 0.42 A 15V @ 0.33 A 81% 83% 84% AEE01AA12-4 AEE00BB12-4 AEE00CC12-4 NOTES: Enable Function "4" = positive logic enable Trim Feature "9" = Trim feature Mechanical Dimensions and Pin Assignments Notes: 1. 20 MHz bandwidth. An external 0.1 uf ceramic capacitor is recommended to be placed from +V out to comm. 2. All specifications are typical at nominal line, full load, and 25C unless otherwise noted. 3. All specifications subject to change without notice. 4. Mechanical drawings are for reference only. www.astec.com 3