© 2018 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com 732 Page 1
Series 732
DPDT Non-Latching
Commercial Electromechanical Relay
732\082018\Q3
SERIES RELAY TYPE
732 DPDT basic relay
732D DPDT relay with internal diode for coil transient suppression
732TN DPDT relay with internal transistor driver and coil transient suppression diode
DESCRIPTION
The TO-5 relay, originally conceived and developed by Teledyne, has
become one of the industry standards for low-level switching from dry circuit
to 1 ampere. Designed for high-density PC board mounting, the Series
732 relays are some of the most versatile ultraminiature relays available
bec au se of t he ir sm all s ize an d lo w c oil p owe r dis si pat io n.
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability:
The 732 feature:
•All welded construction.
• Unique uni-frame design providing high magnetic eff iciency and
mechanical rigidit y.
• Hig h fo rc e /mas s ra ti os f or r esi st an c e to sh oc k an d vi br ati on.
• Advan c ed c l ea nin g te ch ni qu es p rov id e ma x im um as s ura nc e of i nte r na l
cleanliness.
• Prec i ou s met al a ll oy c ont a ct m ate r ial w it h g ol d pl ati ng as s ure s exce ll ent
hig h cu r re nt and d ry c ir c uit s wi tc hin g c ap ab ili t ie s.
The S er i es 73 2D r el ay has an i nte rn al d isc r ete si li c on di o de f or c o il
tra nsi ent s up pr es si on. T he hy br i d Se r ie s 732 TN r el ay has a n inte r nal
sili c on d io de a nd t r ans ist or dr i ver. The inte gr ate d pa ck ag ing o f th e re lay
wit h it s as so c iate d s emi c on du ct or d evi c es gr ea tl y re duc e s PC b o ard fl o or
space requirements as well as c omponent installation costs.
By virtue of i ts i nh ere nt ly l ow int erc o nt ac t c ap ac it an c e an d c ont ac t c ir c uit
los se s, t he 73 2 has p rove n to b e exce ll ent ul tr am in iat ure R F sw it ch f or
fre qu enc y ra ng es we ll int o th e U HF s pe ct r um . A t yp ic a l RF a pp licat io n fo r
the TO-5 rel ay is in h an dhe ld r ad io t r ans c ei ver s, w he re in t he co mb ine d
featu re s of go od R F p erf or m anc e, s mal l size, l ow c o il p ower d is sip ati on
and hi gh r el ia bi lity m ake it a p ref er r ed m et ho d of Transmit - R ec e ive
switching
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Operating) –55°C to +85°C
Vibration
(General Note I) 10 g’s to 500 Hz
Shock
(General Note I)
30 g’s,
6ms half sine
Enclosure Hermetically sealed
Weight 0.09 oz. (2.55g) max.
INTERNAL CONSTRUCTION
UPPER
STATIONARY
CONTACT
LOWER
STATIONARY
CONTACT
UNI-FRAME
ARMATURE
MOVING
CONTACT
COMMERCIAL
SENSITIVE TO-5 RELAYS
DPDT
732 Y M4 - 26 / S Q
Relay Series
Ground Pin Option
(See Appendix)
Pad Option
(See Appendix)
Q = Solder-Coated Leads1
G = Gold-Plated Leads (RoHS Compliant)
R = RoHS Compliant Solder2
S = 0.187” Leads
No Suf x = 0.75” Leads
Nominal Coil Voltage
(26 = 26.5 V, See Page 2 for more Voltages)
Part Numbering System
732 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2018 TELEDYNE RELAYS
Series 732
DPDT Non-Latching
Commercial Electromechanical Relay
732\082018\Q3
TYPICAL DC CONTACT RATING (RESISTIVE)
LOAD VOLTAGE (VDC)
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01 0.5 .1 .5 1.0
FREQUENCY (GHz)
FIGURE 1
TYPICAL RF PERFORMANCE
1.92
1.22
1.07
1.02
1.01
1.00
1.00
VSWR
dB
RETURN LOSS (VSWR)
ISOLATION ACROSS CONTACTS
ISOLATION ACROSS POLES
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
FIGURE 2
INSERTION LOSS
GENERAL NOTES
1. Relay contacts will exhibit no chatter in
excess of 10 μsec or transfer in excess
of 1 μsec.
2. “Typical” characteristics are based on
available data and are best estimates.
No on-going verification tests are
performed.
3. Unless otherwise specified, parameters
are initial values.
4. Relays can be supplied with a spacer
pad. See appendix.
PERFORMANCE CURVES (Note 2)
SERIES 732
GENERAL ELECTRICAL SPECIFICATIONS (@25°C)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.15 Ω max.; 0.25 Ω max. afterlife at A / 28 Vdc
Contact Load Rating (DC)
Resistive: 1 A/ 28 Vdc
Inductive: 200 mA/ 28 Vdc (320mH)
Lamp: 100 mA / 28 Vdc (320mH)
Low level: 10 to 50 μA @ 10 to 50 mV
Contact Load Rating (AC) Resistive: 250 mA / 115Vac, 60 and 400 Hz (Case not grounded)
100 mA / 115 Vac, 60 and 400 Hz (Case grounded)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5 A / 28 Vdc resistive
100,000 cycles min. at all other loads speci ed above
Contact Overload Rating 2 A / 28 Vdc Resistive (100 cycles min.)
Coil Operating Power 200 mW typical at nominal rated voltage
Contact Carry Rating Contact Factory
Operate Time 6.0 msec max. at nominal rated coil voltage
Release Time 732: 3.0 ms max. 732D, 732TN: 7.5 ms max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 1,000 MΩ min. between mutually isolated terminals
Dielectric Strength 350 Vrms (60 Hz) @ atmospheric pressure
Negative Coil Transient (Vdc) 2.0 Vdc Max.
Diode P.I.V. (Vdc) 60 Vdc Min.
732TN Transistor
Characteristics
Base Voltage to Turn Off (Vdc) 0.3 min
Emitter-Base breakdown Voltage (BVEBO) (Vdc) 6.0 min
Collector-Base breakdown Voltage (BVCBO) (Vdc) 60 min
BASE PART NUMBERS (732, 732D, 732TN)
732-5
732D-5
732TN-5
732-6
732D-6
732TN-6
732-9
732D-9
732TN-9
732-12
732D-12
732TN-12
732-18
732D-18
732TN-18
732-26
732D-26
732TN-26
Coil Voltage Nom. 5.0 6.0 9.0 12.0 18.0 26.5
Max. 7.5 10.0 15.0 20.0 30.0 40.0
Coil Resistance (Ohms ±20%) 100 200 400 850 1600 3300
Pick-up Voltage (Vdc, Max.) Pulse Operation 3.5 4.5 6.8 9.0 13.5 18.0
732TN Base Current to Turn On (mAdc, min.) 1.5 1.00 0.75 0.47 0.38 0.24
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
© 2018 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com 732 Page 3
Series 732
DPDT Non-Latching
Commercial Electromechanical Relay
732\082018\Q3
SERIES 732
OUTLINE DIMENSIONS
NOTES:
1. RELAY CONTACTS WILL EXHIBIT NO CHATTER IN EXCESS OF 10 ΜSEC OR TRANSFER IN EXCESS OF 1 ΜSEC.
2. “TYPICAL” CHARACTERISTICS ARE BASED ON AVAILABLE DATA AND ARE BEST ESTIMATES. NO ON-GOING VERIFICATION
TESTS ARE PERFORMED.
3. UNLESS OTHERWISE SPECIFIED, PARAMETERS ARE INTIAL VALUES.
4. FOR REFERENCE ONLY. COIL RESISTANCE NOT DIRECTLY MEASURABLE ON 732TN RELAYS.
5. CIRCUIT IS TYPICAL FOR ALL SERIES 732TN. VALUES SHOWN ARE FOR 732TN-5 RELAY AND APPLY FOR FULL
TEMPERATURE RANGE.LIMIT BASE-EMITTER CURRENT TO 15 MADC.
6. UNLESS OTHERWISE SPECIFIED, RELAYS WILL BE SUPPLIED WITH EITHER GOLD-PLATED OR SOLDER-COATED LEADS.
7. THE SLASH AND CHARACTERS APPEARING AFTER THE SLASH ARE NOT MARKED ON THE RELAY.
SCHEMATIC DIAGRAMS
732 732D
2
3
4
1
8
7
6
9
2
3
4
1
8
7
6
9
732TN
2
3
4
1
8
7
6
9
10
Vcc Vr
Notes:
Logic 1 activates the relay.
Logic 0 de-activates the relay.
Vcc = logic bias power.
Vr = coil energization voltage.
Pin 10
Pin 9
Pin 1
Logic element
1 = 0.50 to 3.00mA
0 = 0.3Vdc min.
TYPICAL LOGIC INTERFACE
(See Note 5)
.370
(9.40)
DIA. MAX.
CASE DETAIL
.335
(8.51)
DIA. MAX.
.385 (9.76) MAX.
WIRE LEAD: .75 (19.05) MIN.
.017 (.43) DIA.
+.002 (.05)
–.001 (.03) (Viewed From Terminals)

75$16,6725%$6(
&211(&7,21)25
7121/<
TERMINAL LOCATIONS AND PIN NUMBERING (REF. ONLY)
(Viewed from Terminals)




 
7<3

',$
Page 4 (800) 284-7007 • www.teledynerelays.com • +44 (0) 1236 453124 • www.teledyne-europe.com © 2016 TELEDYNE RELAYS
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M4” Pad for TO-5
ER412, ER412D, ER412DD .295 (7.49)
712, 712D, 712TN,
RF300, RF310, RF320
RF700, RF703
.300 (7.62)
ER420, ER420D, ER420DD, 421,
ER421D, ER421DD, ER422, ER422D,
ER422DD, 722, 722D, RF341
.305 (7.75)
ER431T, ER432T,
ER432, ER432D, ER432DD .400 (10.16)
732, 732D, 732TN, RF303, RF313,
RF323 .410 (10.41)
RF312, RF332
SI800, SI803 .350 (8.89)
“M4” Pad for TO-5
ER411, ER411D, ER411DD, ER411T .295 (7.49)
ER431, ER431D, ER431DD .400 (10.16)
RF311 .300 (7.62)
RF331 .410 (10.41)
“M4” Pad for Centigrid®
172, 172D .305 (7.75)
ER114, ER114D, ER114DD,
J114, J114D, J114DD .300 (7.62)
ER134, ER134D, ER134DD,
J134, J134D, J134DD .400 (10.16)
RF100 .315 (8.00)
RF103 .420 (10.67)
“M9” Pad for Centigrid®
122C, A152 .320 (8.13)
ER116C, J116C .300 (7.62)
ER136C, J136C .400 (10.16)
RF180 .325 (8.25)
A150 .305 (7.75)
Notes:
1. Spacer pad material: Polyester lm.
2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering
example in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010” (.25 mm).
5. Add 10 mΩ to the contact resistance shown in the datasheet.
6. Add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
Ø.150
[3.81]
(REF)
Dim H
MAX
Dim H
MAX
Dim H
MAX
.156
[3.96]
(REF)
.256
[6.5]
(REF)
Dim H
MAX
APPENDIX: Spacer Pads
© 2016 TELEDYNE RELAYS SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Page 5
Pad designation and
bottom view dimensions Height For use with the following: Dim. H
Max.
“M” Pad 5/ 6/
ER411T, J411T, ER412, ER412D
ER412DD, J412, J412D, J412DD
ER412T, J412T
.388 (9.86)
712, 712D, 712TN .393 (9.99)
ER431T, J431T, ER432, ER432D
ER432DD, J432, J432D, J432DD
ER432T, J432T
.493 (12.52)
732, 732D, 732TN .503 (12.78)
ER420, J420, ER420D, J420D
ER420DD, J420DD, ER421, J421
ER421D, J421D, ER421DD
J422D, ER422DD, J422DD, 722
.398 (10.11)
“M2” Pad 7/ 8/
ER411T
ER412, ER412D, ER412DD
J412, J412D, J412DD .441 (11.20)
712, 712D .451 (11.46)
ER421, ER421D, ER421DD
722, 732D .451 (11.46)
ER431T
ER432, ER432D, ER432DD .546 (13.87)
732, 732D .556 (14.12)
“M3” Pad 5/ 6/ 9/
ER411, ER411D, ER411DD, ER411TX
ER412X, ER412DX, ER412DDX
ER412TX
.388 (9.86)
712X, 712DX, 712TNX .393 (9.99)
ER420X, ER420DX, ER420DDX
ER421X, ER421DX, ER421DDX
ER422X, ER422DX
ER422DDX, 722X, 722DDX
.398 (10.11)
ER431, ER431D, ER431DD
ER431TX
ER432X, ER432DX, ER432DDX
ER432TX
.493 (12.52)
732X, 732DX, 732TNX .503 (12.78)
Notes:
1. Spreader pad material: Diallyl Phthalate.
2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example
in the applicable datasheet.
3. Dimensions are in inches (mm).
4. Unless otherwise speci ed, tolerance is ± .010” (0.25 mm).
5/. Add 25 mΩ to the contact resistance shown in the datasheet.
6/. Add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet.
7/. Add 50 mΩ to the contact resistance shown in the datasheet.
8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet.
9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.)
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
.390 [9.91]
SQ
.300
[7.62]
.100
[2.54]
.300
[7.62]
.100
[2.54] .150
[3.81]
.150
[3.81]
.130
[3.3]
Dim H
MAX
.370 [9.4]
MAX SQ
.150
[3.81]
.100
[2.54]
.200
[5.08]
.300
[7.62]
.100
[2.54]
Dim H
MAX
.370
[9.4]
MIN
.014
[0.36]
(REF)
APPENDIX: Spreader Pads
Page 6 (800) 284-7007 • www.teledynerelays.com • +44 (0) 1236 453124 • www.teledyne-europe.com © 2016 TELEDYNE RELAYS
.100
[2.54]
.100
[2.54]
.100
[2.54]
"Y" POSITION
"Z" POSITION
.100
[2.54]
.100
[2.54]
.100
[2.54]
"W" POSITION
"U" POSITION
(ER116C and ER136C only)
"X" POSITION
"Z" POSITION
"Y" POSITION
.050
[1.27]
36°±3°
Ø.200
[Ø5.08]
"Z" POSITION
"Y" POSITION
"X" POSITION
45°±3°
"Z" POSITION
"Y" POSITION
Ø.200
[Ø5.08]
Centigrid® Relays:
RF100, RF103, ER114, ER134, 172
Centigrid® Relays:
RF180, ER116C, 122C, ER136C
TO-5 Relays:
ER411T, ER412, ER412T, ER420, ER421, ER422,
ER431T, ER432, ER432T, 712, 712TN, 400H, 400K,
400V, RF300, RF303, RF341, RF312, RF332, RF310,
RF313, RF320, RF323, SI800, SI803, RF700, RF703
TO-5 Relays:
ER411, ER431, RF311, RF331
NOTES
1. Terminal views shown
2. Dimensions are in inches (mm)
3. Tolerances: ± .010 (±.25) unless otherwise speci ed
4. Ground pin positions are within .015 (0.38) dia. of true position
5. Ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref.
6. Lead dia. 0.017 (0.43) nom.
Indicates ground pin position
Indicates glass insulated lead position
Indicates ground pin or lead position
depending on relay type
APPENDIX: Ground Pin Positions
Loopback Relays:
LB363
“Z” Position
“Y” Position