Up counters/Down
-
48 x 48
-
CTR48 Orange backlit LCD display Part number 87621125
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
Maximum input frequency 40 k Hz
Simple parameter setting, configuration using text menus
Easy modification of presets
Scaling factor
5 A changeover relay and solid state output
Removable connectors
Backlit LCD display (orange) : 2 lines, 6 digits or multicoloured display (green-red)
IP 65 sealed panel
Option of locking the keypad, completely or partially (preset, programming)
Accessories for 72 x 72 or 55 x 55 cut-out, DIN rail adaptor
Part numbers
Specifications
Orange backlit LCD
display
Counter, Tachometer, Chronometer, Multi
-totalizer, Batch counter, Preselection
totalizer
1 changeover relay, 1 NO relay, 2 solid
state
Physical details and protection
10→30VDC/24VAC/90→260VAC
Relative humidity (no condensation)
EN 60068
-2-
30 40/93 % RLF
UL
- cULus (pending) -
CE
Vibration resistance in 3 axes
10-
55 Hz/1 min/XYZ EN 60068
-2-
6 : 30 min. in each direction
Connection by screw terminals
Conforming to standard EN 60529 IP65 for panel/IP20 for connections
Front panel watertight seal
Temperature limits use (°C)
Temperature limits stored (°C)
150
DC version
250 AC version
Reset to zero or to preset
On panel : if not locked during programming
Electrical : automatic, voltage or solid state (NPN or PNP depending on programming)
Impulse counter : < 15 ms
Chronometer : 500
μ
s
Option to protect against reset from front panel
Scale factor (each input pulse is multiplied by this figure)
Scaling factor (each input impulse is divided by this
value)
Decimal point selectable for ease of reading
0
0,0
0,00
0,000
0,0000
0,00000
Programming and current value backed up via EEPROM
memory
Operating characteristics
Preselection counter, Tachometer, Chronometer, Multi
-totalizer, Batch counters, Totalizer
LCD with orange backlighting/Multicoloured LCD (green
-red)
-999999→999999
2 counter inputs
1 reset input, 1 gate input
Dir : Directional
AS : up/dn
AA : up/up
PP : phase
PP2 : phase 2
PP4 : phase 4
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
23/06/2014 www.crouzet.com