S172 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2019 TELEDYNE RELAYS
Series S172
DPDT Non-Latching
Commercial Electromechanical Relay
S172\112019/Q4
SERIES S172
GENERAL ELECTRICAL SPECIFICATIONS (-55 °C to 85 °C unless otherwise noted. See notes 2 & 3.)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.15 Ω max.
Contact Load Rating
Resistive: 1 A/ 28 Vdc
Inductive: 200 mA/ 28 Vdc (320mH)
Lamp: 100 mA / 28 Vdc (320mH)
Low level: 10 to 50 μA @ 10 to 50 mV
Contact Life Ratings
5,000,000 cycles (typical) at low level
500,000 cycles (typical) at 0.5 A / 28 Vdc resistive
100,000 cycles min. at all other loads specifi ed above
Contact Overload Rating 2 A / 28 Vdc Resistive (100 cycles min.)
Contact Carry Rating Contact Factory
Operate Time 6.0 msec max. at nominal rated coil voltage
Release Time S172: 3.0 ms max. S172D: 6.0 ms max.
Contact Bounce 1.5 msec max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 1,000 MΩ min. between mutually isolated terminals
Dielectric Strength 300 Vrms (60 Hz) @ atmospheric pressure
Negative Coil Transient (Vdc) 2.0 Vdc Max.
Diode P.I.V. (Vdc) 60 Vdc Min.
BASE PART NUMBERS (S172, S172D) S172-5
S172D-5
S172-12
S172D-12
S172-26
S172D-26
Coil Voltage Nom. 5.0 12.0 26.5
Max. 5.8 16.0 32.0
Coil Resistance (Ohms ±25%) 64 400 1600
Pick-up Voltage (Vdc, Max.) Pulse Operation 3.8 9.0 18.0
Coil Operating Power at Nominal Voltage (mW) 405 360 440
DETAILED ELECTRICAL SPECIFICATIONS (-55 °C to 85 °C unless otherwise noted. See note 2.)