XL SERIES
RELAY – LATCH
2PDT, LO W LE VEL TO 5 AMP
AMERICAS.
Tel: +1 714-736-7599
http://www.esterline.com/powersystems
EUROPE.
Tel: +33 3 87 97 31 01
Fax: +33 3 87 97 96 86
ASIA
Tel: +852 2 191 3830
Fax: +852 2 389 5803
The technical information provided by Esterline Power Systems is to be used as a guide only, and is not meant for publication or as documentation for altering any existing
specification. Dimensions are in inches unless otherwise specified. Rev. 11/2017.
1 / 5
Magnetic latch operation
All weld construction
Contact arrangement
2 PDT
Qualified to
MIL-PRF-6106
PRINCIPL
E TECHNICAL CHARACTERISTICS
Contacts rated at Low level, 28 Vdc and 115/200
Vac, 400Hz, 3Ø, case grounded
Weight 0.036 lbs. max
Dimensions 0.41in x 0.81in x 0.64in
• Special models available upon request
• Hermetically sealed, corrosion resistant can
A pplicable Socket:
SO-1064-003
Application Notes:
001
002
103B
007
CONTACT ELECTRICAL CHARACTERIST ICS
Contact rating per pole
and load type [1] Load current in Amps
28 Vdc 115 Vac, 400 Hz, 1Ø 115/200 Vac, 400 Hz, 3Ø
Resistive 5 5 5
Inducti ve [2] 3 5 5
Motor 2 3 3
Lamp 1 1 -
Overload 20 30 30
Rupture 25 40 40
Low level [3] - - -
Time current characteristics [4] - - -
XL SERIES
RELAY – LATCH
2PDT, LO W LE VEL TO 5 AMP
2 / 5
COIL CHARACTERISTICS (Vdc)
GENERAL CHARACTERISTICS
Unless otherwise noted, the specified temperature range applies to all relay characteristics.
CODE A B C N [5] R [5] V [5]
Nominal operating voltage
28
12
6
28
12
6
Maximum operating voltag e @125°C 29 14.5 7.3 29 14.5 7.3
Maximum picku p vol tag e
- Cold coil at +125° C
18
9
4.5
18
9
4.5
- During high temp test at +125° C
19.8
9.9
5
19.8
9.9
5
- During continuous curr ent test at +125° C
22.5
11.25
5.7
22.5
11.25
5.7
Coil resistance in Ω ±10% at +25° C except
types "C" and "R" +20%, - 10%
730 182 43 730 182 43
Temperature range -70°C to +125°C [7]
Minimum operating cycles (life) at rated lo ad
100,000 [2]
Minimum operating cycles (life) at 25% rated load
400,000
Dielectric str ength at sea level
- All circuits to ground and circuit to circuit 1000 Vrms
- Coil to ground and coil to coil 500 Vrms
Dielectric str ength at altitu d e 80,000 ft 500 Vrms [6]
Insulation resistan ce
- Initial (500 Vdc) 100 M Ω min
- After environmental tests (500 Vdc)
50 M Ω min
Sinusoidal vibration (A, D and J mounting) 0.12 d.a. / 10 to 70 Hz
30G / 70 to 3000 Hz
Sinusoidal vibration (G mounting) 0.12 d.a. / 10 to 57 Hz
20G /57 to 3000 Hz
Random vibration
- Applicable specification MIL-STD-202
- Method
214
- Test condition - A, D and J mounting
1G (0.4G2/Hz, 50 to 2000 Hz)
- Test condition - G mou nt ing
1E (0.2G2/Hz, 50 to 2000 Hz)
- Duration
15 minutes each plane
Shock (A, D and J mounting)
200G / 6 ms
Shock (G mounting)
100G / 6 ms
Maximum contact opening time under vibration and shock
10 μs
Operate time at nominal voltage@25°C
4 ms max
Release time at nominal voltage@25°C
4 ms max
Contact make bounce at nominal voltage@25°C
1.0 ms max
Weight maximum
0.036 lbs.
XL SERIES
RELAY – LATCH
2PDT, LO W LE VEL TO 5 AMP
3 / 5
MOUNTING STYLES
Dimensions in inches
Tolerances, unless otherwise specified, ± 0.03 in
XL SERIES
RELAY – LATCH
2PDT, LO W LE VEL TO 5 AMP
4 / 5
TERMINAL TYPES
Dimensions in inches
Tolerances, unless otherwise specified, ± 0.03 in
XL SERIES
RELAY – LATCH
2PDT, LO W LE VEL TO 5 AMP
5 / 5
DIAGRAMS
TOL: .XX ±.03; .XXX ±.010
NUMBERING SYSTEM
Example : XL-A1A-XXX
XL-A1A (Commercial)
XL-A1A-003 (MIL)
XL-A1A-123 (Customer P ar t)
NOTES
1. Standard In termed i ate Current test applicab l e; relay can also switch low level loads while switching any of the other
rated loads on adjacent contacts.
2. Inductive load life: 20,000 cycles.
3. Low level enduran ce test: contact load of 10 to 50 millivolt, 10 to 50 microamp, 100 Ohm max. contact resistance.
4. Refer to MIL-PRF-6106 for details.
5. "N" " R" & "V" coils have back EMF suppression to 42 volts maximum.
6. 500 Vrms with sili cone rubber gasket compressed, 250 Vrms all other condition s.
7. "N", "R" & "V" coils derated to 85° C.
8. Reference MIL-PRF-6106/38
9. Relay will not be damaged, but may transfer with application of reverse polarity to coil.
For any inquiries, please cont act your local Esterl i ne Power Syst ems represent at i ve
http://www.esterline.com/powersystems/Contact/TheAmericas.aspx
XL
-
A
1
A
-
XXX
Basic series designation
1. Mounting styles (A, D , E, G, J)
2. Terminal t ypes (1, 2, 4,)
3. Coil vol tage, see coil characteristi cs (A, B, C, M, N, R, V)
4. XXX Designator s
Dimensions in inches
Tolerances, unless otherwise specified, ± 0.03 in
Bottom View