2
M57145L-01
DC-to-DC Conver ter
Hybrid Gate Drive Power Supply
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings, Ta = 25°C unless otherwise specified
Item Symbol Test Conditions Limit Units
Input Voltage VI—18Volts
Load Current 1 IL1 3 pin Output Current 100* mA
Operating Temperature T opr No Condensation -10 ~ 70 °C
Storage Temperature tstg No Condensation -20 ~ 85 °C
Electrical Isolation between Input and Outputs VRMS Sinewave Voltage, 60Hz, 1 min. 2500 Volts
Electrical Characteristics, Ta = 25°C, VIN = 15V unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Input Voltage VIRecommended Range 12 — 18 Volts
Output V oltage 1 VO1 3 pin Voltage, IO = 0 ~ 60mA 22.8 24.0 25.2 Volts
Output V oltage 2 VO2 2 pin Voltage, No Load of 2 , 3 pins 7.96 8.2 8.43 Volts
Input Regulation Reg-I IL = 60mA, V1 = 12 ~ 18V, — — 50 mV
No Load of 2 pin
Load Regulation Reg-L IL = 0 ~ 60mA, No Load of 2 pin — — 50 mV
Efficiency IL = 60mA, No Load of 2 pin — 68 — %
*Refer to the Derating Characteristic Curve.
LOAD CURRENT, IL1, (mA)
EFFICIENCY,
, (%)
EFFICIENCY VS. LOAD CURRENT
100
0204060
80
60
40
20
010080
INPUT VOLTAGE, VI, (VOLTS)
INPUT CURRENT, I, (mA)
INPUT CURRENT VS. INPUT VOLTAGE
400
051015
300
200
100
0
Ta = 25°C
IL = 60 mA
20
INPUT VOLTAGE, VI, (VOLTS)
OUTPUT VOLTAGE, VO, (VOLTS)
OUTPUT VOLTAGE VS. INPUT VOLTAGE
051015
25
30
20
10
15
5
0
Ta = 25°C
20
Ta = 25°C
VI = 12V
VI = 18V VI = 15V
AMBIENT TEMPERATURE, Ta, (°C)
LOAD CURRENT, IL, (mA)
LOAD CURRENT DERATING CHARACTERISTIC
120
140
0204060
100
80
60
40
20
010080
Ta = 25°C
VI = 12V
VI = 18V
IL = 60 mA
IL = 100 mA