Model AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
AC Clamp Meter
Electrical
AC/DC Clamp Meter
Electrical
AC Clamp Meter
HVAC
AC/DC Clamp Meter
Electrical Motor
Maintenance
AC/DC 1000 A Clamp Meter
Industrial Motor Maintenance
Safety Rating
CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V
Jaw Opening
1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
AC Voltage
(True-RMS)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz)
Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD (50 to 60 Hz)
±1.5% + 5LSD (20 to 200 Hz)
±10% + 5LSD (200 to 400 Hz)
DC Voltage
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
Range: 0 to 1000 V
Accuracy: ±0.8% + 5LSD
AC+DC Voltage
–
Range: 0 to 600.0 V
Accuracy: 1.2% ± 7LSD (DC,
50 to 60 Hz)
–
Range: 0 to 600.0 V
Accuracy: 1.2% ± 7LSD (DC, 50
to 60 Hz)
Range: 0 to 1000 V
Accuracy:
±1.0% + 7LSD (50 to 60 Hz)
±1.8% + 7LSD (DC, 40 to 200 Hz)
±12% + 7LSD (200 to 400 Hz)
AC Current
(True-RMS)
Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)
Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 100 Hz)
±2.0% + 5LSD (100 to 400 Hz)
Range: 0 to 1000 A
Accuracy:
±1.8% + 5LSD (40 to 100 Hz)
±2.2% + 5LSD (100 to 400 Hz)
DC Current
–
Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD
–
Range: 0 to 600.0 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 1000 A
Accuracy: ±1.8% + 5LSD
AC+DC Current
–
Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)
–
Range: 0 to 600.0 A
Accuracy: ±2.2% + 7LSD
(DC, 50 to 100 Hz)
±2.7% + 7LSD (100 to 400 Hz)
Range: 0 to 1000 A
Accuracy: ±2.2% + 7LSD (DC, 40 to 100 Hz)
±2.5% + 7LSD (100 to 400 Hz)
Precise Low
Current AC
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz)
Range: 0 to 60.00 A
Accuracy:
±1.5% + 5LSD (0.00 to 20.00 A, 40 to 100 Hz)
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 40 to 100 Hz)
±3.0% + 5LSD (20.00 to 60.00 A, 100 to 400 Hz)
Precise Low
Current DC
–Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD –Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (0.00 to 20.00 A)
±3.0% + 5LSD (20.00 to 60.00 A)
Precise Low
Current AC+DC
–
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)
–
Range: 0 to 60.00 A
Accuracy: ±2.0% + 5LSD
(DC, 50 to 60 Hz)
Range: 0 to 60.00 A
Accuracy:
±2.0% + 7LSD (0.00 to 20.00 A, DC, 40 to 100 Hz)
±2.2% + 7LSD (0.00 to 20.00 A, 100 to 400 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, DC, 40 to 100 Hz)
±3.0% + 7LSD (20.00 to 60.00 A, 100 to 400 Hz)
Frequency
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (600 A range)
Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (1000 V range)
Range: 40.0 to 400.0 Hz
Accuracy: ±1.0% + 5LSD (1000 A range)
Resistance
Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance
Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Continuity
Beeper
ON ≤ 10 Ω
OFF > 250 Ω
ON ≤ 10 Ω
OFF > 250 Ω
Non-Contact
Voltage
10V to 1000V AC, 50/60Hz 10V to 1000V AC, 50/60Hz
True-RMS
• • • • •
Low Pass Filter
• • • • •
Autoranging
• • • • •
Relative Zero
• • • • •
MAX/MIN/AVG
• • • • •
Diode Test
• • • • •
Data Hold
• • • • •
Backlight
• • • • •
Auto Power Off
• • • • •
300 Series:
DC Microamps
– – Range: 0.0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Temperature*
(Type K
thermocouple)
*Error does not
include Type-K
thermocouple errors
– –
Range: -40.0 to 752°F, -40.0 to 400°C
Accuracy: -40.0 to 14.0°F (±1.0% +3.0°F), >14.0 to 99.9°F (±1.0% +1.5°F)
100 to 752°F (±1.0% +2°F), -40.0 to -10.0°C (±1.0% +1.5°C)
>-10.0 to 99.9°C (±1.0% +0.8°C), 100 to 400°C (±1.0% + 1°C)
3-Phase and
Motor Rotation
Indication
– – Rotation-R for mains supply
Rotation-M for motors
Inrush Current
– –
• • •
Peak Hold (Crest)
– – – –
•
Work Light
– – – –
•
AMP-200 and AMP-300
Detailed Specifications
©2014 Amprobe® For detailed specications and ordering go to www.Amprobe.com 6003578 BAmprobe® | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623)