AMP-300 Series Motor Maintenance TRMS Clamp Meters The Modern Evolution of the Professional Clamp Meter Amprobe's AMP-300 Series True-RMS Clamp Meters offer a complete range of measuring functions for modern industrial environments, motor testing and HVAC applications. All models feature True-RMS sensing, low pass filters and fast response processors for quick, error-free measurements. The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, and a third input jack enables motor rotation and 3-phase sequence testing. AMP-300 Series Features * True-RMS * Motor Testing Capabilities -- Motor rotation -- 3-phase sequence testing -- Inrush current monitoring during motor start-up * HVAC Features -- Temperature measurement; User selectable F or C -- DC Microamps for flame sensor testing -- Capacitance measurement for start and run motor capacitors * Amp-Tip Function * Low Pass Filter for variable frequency drives * Safety Rated: CAT III 600 V (AMP-310, AMP-320) CAT IV 600 V, CAT III 1000 V (AMP-330) AMP-310 AC Clamp Meter HVAC Amprobe(R) | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623) AMP-320 AC/DC Clamp Meter Electrical Motor Maintenance AMP-330 AC/DC 1000 A Clamp Meter Industrial Motor Maintenance (c)2014 Amprobe(R) For detailed specifications and ordering go to www.Amprobe.com 6003578 B AMP-300 Series Product Details True-RMS for accurate voltage measurements in noisy environments. Low pass filter for current and voltage measurements on variable frequency drives. Amp-Tip function for precise low-current measurement of small diameter wires down to 0.1 Amp to help with electrical system troubleshooting. Non-contact voltage detection (NCV) Measurements: Model AMP-310 AMP-320 AMP-330 CAT III 600 V CAT III 600 V CAT IV 600 V CAT III 1000 V Up to 600 V AC/DC Up to 600 V AC/DC Up to 1000 V AC/DC AC Current Up to 600 A Up to 600 A Up to 1000 A Data hold, relative zero, MAX/MIN/AVG mode DC Current - Up to 600 A Up to 1000 A Large LCD backlit display Capacitance Audible continuity and diode test Safety Rating Voltage Frequency 5 to 999 Hz Resistance Temperature 0 to 60 k 0.0 to 2500 F * * * Safety rated CAT III 600 V (AMP-310, AMP-320) CAT IV 600 V CAT III 1000 V (AMP-330) AMP-300 Series Applications * Accurate measurement of current, voltage and frequency on all electrical systems including distorted, non-sinusoidal signals (True-RMS function) and variable frequency drives (low pass filter). * 3-phase Motor and Phase Rotation Tests allow proper connection of a motor to a 3-phase system. Improperly connected motors will spin in a reverse direction, which may destroy the motor or equipment connected to it. * Capacitance measurement for start and run motor capacitors. * Low Pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency). Without this feature, the meter would provide erroneous readings when measuring voltage and current. * Resistance and continuity functions to verify quality of electrical connections and to check if motor and transformer coils are working properly. AMP-310 AC Clamp Meter HVAC AMP-320 AC/DC Clamp Meter Electrical Motor Maintenance Amprobe(R) | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623) * DC Microamps output for measurement of flame sensors. Test the proper operation of the flame sensor safety system in gas appliances. A broken sensor in a gas appliance will prevent the safety valve from opening and the appliance will not work. * Inrush current measurement for motor start-up monitoring, allowing users to verify that the motor is receiving the required inrush current to support proper motor start. AMP-330 AC/DC 1000 A Clamp Meter Industrial Motor Maintenance (c)2014 Amprobe(R) For detailed specifications and ordering go to www.Amprobe.com 6003578 B AMP-200 and AMP-300 Detailed Specifications Model AMP-210 AMP-220 AMP-310 AMP-320 AMP-330 AC Clamp Meter Electrical AC/DC Clamp Meter Electrical AC Clamp Meter HVAC AC/DC Clamp Meter Electrical Motor Maintenance AC/DC 1000 A Clamp Meter Industrial Motor Maintenance Safety Rating CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V, CAT III 1000 V Jaw Opening 1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm) AC Voltage (True-RMS) Range: 0 to 600.0 V Accuracy: 1.0% + 5LSD (50 to 60 Hz) Range: 0 to 600.0 V Accuracy: 1.0% + 5LSD (50 to 60 Hz) Range: 0 to 1000 V Accuracy: 0.8% + 5LSD (50 to 60 Hz) 1.5% + 5LSD (20 to 200 Hz) 10% + 5LSD (200 to 400 Hz) DC Voltage Range: 0 to 600.0 V Accuracy: 1.0% + 5LSD Range: 0 to 600.0 V Accuracy: 1.0% + 5LSD Range: 0 to 1000 V Accuracy: 0.8% + 5LSD AC+DC Voltage AC Current (True-RMS) - Range: 0 to 600.0 V Accuracy: 1.2% 7LSD (DC, 50 to 60 Hz) Range: 0 to 600.0 A Accuracy: 1.8% + 5LSD (50 to 100 Hz) 2.0% + 5LSD (100 to 400 Hz) - Range: 0 to 1000 V Accuracy: 1.0% + 7LSD (50 to 60 Hz) 1.8% + 7LSD (DC, 40 to 200 Hz) 12% + 7LSD (200 to 400 Hz) Range: 0 to 600.0 V Accuracy: 1.2% 7LSD (DC, 50 to 60 Hz) Range: 0 to 600.0 A Accuracy: 1.8% + 5LSD (50 to 100 Hz) 2.0% + 5LSD (100 to 400 Hz) Range: 0 to 1000 A Accuracy: 1.8% + 5LSD (40 to 100 Hz) 2.2% + 5LSD (100 to 400 Hz) DC Current - Range: 0 to 600.0 A Accuracy: 2.0% + 5LSD - Range: 0 to 600.0 A Accuracy: 2.0% + 5LSD Range: 0 to 1000 A Accuracy: 1.8% + 5LSD AC+DC Current - Range: 0 to 600.0 A Accuracy: 2.2% + 7LSD (DC, 50 to 100 Hz) 2.7% + 7LSD (100 to 400 Hz) - Range: 0 to 600.0 A Accuracy: 2.2% + 7LSD (DC, 50 to 100 Hz) 2.7% + 7LSD (100 to 400 Hz) Range: 0 to 1000 A Accuracy: 2.2% + 7LSD (DC, 40 to 100 Hz) 2.5% + 7LSD (100 to 400 Hz) Precise Low Current AC Precise Low Current DC Precise Low Current AC+DC Range: 0 to 60.00 A Accuracy: 1.5% + 5LSD (50 to 60 Hz) - Range: 0 to 60.00 A Accuracy: 2.0% + 5LSD - Range: 0 to 60.00 A Accuracy: 2.0% + 5LSD (DC, 50 to 60 Hz) Range: 0 to 60.00 A Accuracy: 1.5% + 5LSD (0.00 to 20.00 A, 40 to 100 Hz) 2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) 3.0% + 5LSD (20.00 to 60.00 A, 40 to 100 Hz) 3.0% + 5LSD (20.00 to 60.00 A, 100 to 400 Hz) Range: 0 to 60.00 A Accuracy: 1.5% + 5LSD (50 to 60 Hz) - Range: 0 to 60.00 A Accuracy: 2.0% + 5LSD Range: 0 to 60.00 A Accuracy: 1.5% + 5LSD (0.00 to 20.00 A) 3.0% + 5LSD (20.00 to 60.00 A) - Range: 0 to 60.00 A Accuracy: 2.0% + 5LSD (DC, 50 to 60 Hz) Range: 0 to 60.00 A Accuracy: 2.0% + 7LSD (0.00 to 20.00 A, DC, 40 to 100 Hz) 2.2% + 7LSD (0.00 to 20.00 A, 100 to 400 Hz) 3.0% + 7LSD (20.00 to 60.00 A, DC, 40 to 100 Hz) 3.0% + 7LSD (20.00 to 60.00 A, 100 to 400 Hz) Range: 5.00 to 999.9 Hz Accuracy: 1.0% + 5LSD (600 V range) Range: 50.0 to 400.0 Hz Accuracy: 1.0% + 5LSD (600 A range) Range: 5.00 to 999.9 Hz Accuracy: 1.0% + 5LSD (1000 V range) Range: 40.0 to 400.0 Hz Accuracy: 1.0% + 5LSD (1000 A range) Frequency Range: 5.00 to 999.9 Hz Accuracy: 1.0% + 5LSD (600 V range) Range: 50.0 to 400.0 Hz Accuracy: 1.0% + 5LSD (600 A range) Resistance Range: 0.0 to 60.00 k Accuracy: 1.0% + 5LSD Range: 0.0 to 60.00 k Accuracy: 1.0% + 5LSD Capacitance Range: 0.0 to 2500 F Accuracy: 2.0% + 4LSD Range: 0.0 to 2500 F Accuracy: 2.0% + 4LSD Continuity Beeper Non-Contact Voltage True-RMS ON 10 OFF > 250 ON 10 OFF > 250 10V to 1000V AC, 50/60Hz 10V to 1000V AC, 50/60Hz * * * * * Low Pass Filter * * * * * Autoranging * * * * * Relative Zero * * * * * MAX/MIN/AVG * * * * * Diode Test * * * * * Data Hold * * * * * Backlight * * * * * Auto Power Off * * * * * - - Range: 0.0 to 2000 A Accuracy: 1.0% + 5LSD - - Range: -40.0 to 752F, -40.0 to 400C Accuracy: -40.0 to 14.0F (1.0% +3.0F), >14.0 to 99.9F (1.0% +1.5F) 100 to 752F (1.0% +2F), -40.0 to -10.0C (1.0% +1.5C) >-10.0 to 99.9C (1.0% +0.8C), 100 to 400C (1.0% + 1C) 3-Phase and Motor Rotation Indication - - Rotation-R for mains supply Rotation-M for motors Inrush Current - - * * * Peak Hold (Crest) - - - - * Work Light - - - - * 300 Series: DC Microamps Temperature* (Type K thermocouple) *Error does not include Type-K thermocouple errors Amprobe(R) | info@amprobe.com | Fluke Corporation, Everett, WA 98203 | Tel: 877-AMPROBE (267-7623) (c)2014 Amprobe(R) For detailed specifications and ordering go to www.Amprobe.com 6003578 B AMP-200 and AMP-300 General Specifications Model AMP-210 AMP-220 AMP-310 AMP-320 AMP-330 Display 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts 3-5/6 digits 6000 counts Polarity Automatic Automatic Automatic Automatic Automatic Update Rate 5 per second nominal 5 per second nominal 5 per second nominal 5 per second nominal 5 per second nominal Operating Temperature 32 to 104F (0 to 40C) 32 to 104F (0 to 40C) 32 to 104F (0 to 40C) 32 to 104F (0 to 40C) 14 to 122F (-10 to 50C) Relative Humidity 80% at 30C, 50% at 40C 80% at 30C, 50% at 40C 80% at 30C, 50% at 40C 80% at 30C, 50% at 40C Non condensing at 10C 90% at 10 to30C 75% at 30 to 40C 45% at 40 to 50C Operating Altitude 0 to 2000 m 0 to 2000 m 0 to 2000 m 0 to 2000 m 0 to 2000 m 2 2 2 2 2 Storage Temperature -4 to 140F (-20C to 60C), < 80% RH -4 to 140F (-20C to 60C), < 80% RH -4 to 140F (-20C to 60C), < 80% RH -4 to 140F (-20C to 60C), < 80% RH -4 to 140F (-20C to 60C), < 80% RH Temperature Coefficient Nominal 0.15 x (specified accuracy)/ C @ (0C to 18C or 28C to 40C) Nominal 0.15 x (specified accuracy)/ C @ (0C to 18C or 28C to 40C) Nominal 0.15 x (specified accuracy)/ C @ (0C to 18C or 28C to 40C) Nominal 0.15 x (specified accuracy)/ C @ (0C to 18C or 28C to 40C) Nominal 0.10 x (specified accuracy)/ C @ (0C to 18C or 28C to 50C) Battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AAA 1.5 V battery Two AA 1.5 V battery EMC Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 Meets EN 61326-1:2006 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 UL/IEC/EN 61010-1 ed. 3.0, IEC/ EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/ EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010031 ed. 1.1 Certification UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE UL (c/us) and CE Dimensions (L x W x H): 8.62 x 3.03 x 1.46 in (219 x 77 x 37 mm) 8.82 x 3.03 x 1.46 in (224 x 77 x 37 mm) 8.62 x 3.03 x 1.46 in (219 x 77 x 37 mm) 8.82 x 3.03 x 1.46 in (224 x 77 x 37 mm) 10.16 x 3.70 x 1.73 in (258 x 94 x 44 mm) 208 g (0.46 lb) 254 g (0.56 lb) 208 g (0.46 lb) 254 g (0.56 lb) 420 g (0.93 lb) User's Manual * * * * * Test Leads * * * * * Carrying Case * * * * Pollution Degree Safety Compliance Weight: Accessories Included: Batteries AAA (2) AAA (2) * AA (2) Alligator Clip Set - - * * * Banana plug K-type Thermocouple - - * * * Amprobe(R) info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) For complete information about Amprobe test tools, visit www.Amprobe.com (c) 2014 Amprobe | Specifications subject to change without notice. Printed In U.S.A. 6003578 B