4/16/2010
LEDWC( )120S035ST LEDWC( )120S045ST LEDWC( )120S070ST LEDWC( )120S105ST LEDWC( )120S140ST LEDWC( )120S175ST LEDWC( )120S210ST
Rated Curr ent (1) 350mA 450mA 700mA 1050mA 1400mA 1750 mA 2100 mA
Current Range (Min - Max) mA 332 - 368 427 - 473 665 - 735 997 - 1102 1330 - 1470 1662 -1837 1995 - 2205
Rated Po wer 120W 120W 120W 120W 120W 120W 120W
Ripple & Noise (max.) (2)
Max. Voltage 343 Vdc 266 Vdc 171 Vdc 114 Vdc 86 Vdc 68 Vdc 57 Vdc
Voltage Range (Min - Max) 206V - 343V 160V - 266V 103V - 171V 68V - 114V 52V - 86V 41V - 68V 34V - 57V
Line Regulation
Load Regula ti on
Setup, Rise Time
Voltage Range
Frequenc y Range
Power Factor Correction
Efficiency (Typ.) at 230Vac 91% 91% 91% 90.5% 90.5% 90.5% 90.5%
Inrush Current
Leakage Current
AC Current
T
p.
OutputInput
1%
3%
65A @ 230VAC Input and 25°C
3% V₀ Pk -Pk
0.6 S
90V ~ 305VAC
47Hz / 63Hz
Model
0.99 @ 100VAC and 0.96 @ 220 VAC
1.5 A / 100VAC 0.75A / 220VAC
1 mA max. at 277 Vac 50Hz input
¾
Ultra High Ef f iciency (Up to 91% )
¾
Acti ve Power Fact or Corr ection (Up to 0.99)
¾
Waterproof (IP67)
¾
Dimming Function
¾
Lightning Protection
¾
Over Voltage, Over Temp. & Short Circuit Protection
¾
Comply with UL8750 & EN61347 Safety Regul ati ons
¾
Very Hi gh MTB F & Life Time
120WConstantCurrentLEDDriverLEDWC120series
FEATURES
SPECIFICATION
Short Circuit Protection
Over Temperature Protection
446V 346V 222V 148V 112V 88V 74V
Operational
Storage
Operational
Storage
Safety Standards
Withstand Voltage
EMI Conduction & Radiation
Harmonic Current
EMS Immunity
MTBF (3)
Life Time (3)
Dimension (L*W*H)
Weight
Safety & EMC
320K HRS Compliance: MIL-HDBK-217F @ 25°C ambient temp.
Over Voltage (Typ.)
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : latch-off mode, Power supply must turn off and on again
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547
Humidity
- 40 ~ +85°C
- 35°C ~ 65°C
10 ~ 100% RH
Temperature Range
5 ~100% R.H
Others Protections
I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute
EN55015 with 6db margin
UL8750 compliance to UL1310 Class 2 UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0)
EN61000-3-2 , EN61000-3-3
80,000 hours @ 45°C ambient temp.
110°C Latch mode. The power supply shall return to normal operation only after the power is turn-on again.
Environmental
194*67.5*37.0 (mm) -7.64*2.66*1.46 (inch)
1000 g
Autec Power Systems
667 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888
Fax: (805)522-8777