6
E3S-LSE3S-LS
Setting sequence Step 1: Finding point A Step 2: Finding point B Step 3: Final setting
Detecting
condition
Sensitivity
adjustment
position
Adjustment Turn the sensitivity adjuster fully Remove the object to be detected, Set the sensitivity adjuster
procedure counterclockwise to the Minimum then turn the sensitivity adjuster fully between reference points
Setting. Place the object to be clockwise to the Maximum setting. "A" and "B". Confirm that
detected in position, then turn the Turn the sensitivity adjuster slowly the STABILITY indicator
sensitivity adjuster slowly clockwise counterclockwise until the LIGHT lights when the object to be
until the LIGHT INCIDENT indicator INCIDENT indicator goes off. This is detected is in place and
lights. This is reference point "A". reference point "B". If the indicator when removed from its
is off at maximum setting, use the specified position.
maximum setting as reference
point "B".
Operation
■ DETECTING DISTANCE ADJUSTMENT
Select the proper detecting distance
adjustment method based on the
conditions listed in the table. Method #2
assumes the amplifier is wired for DARK-
ON operation mode.
Conditions The reflection factor of the The reflection factor of the
object to be detected is object to be detected is
equal to, or higher than, that less than that of the
of the background object. background object.
Adjustment method Use Method 1. Use Method 2.
Adjustment Method 1 Adjustment Method 2
1. Set sensitivity adjuster to center position.
2. Turn the distance adjusting knob fully counterclockwise,
for as many turns as necessary, to reach the shortest
distance setting "S".
3. Place the object to be detected in position.
4. Turn the distance adjusting knob slowly clockwise, from
shortest distance setting "S" toward longest distance
setting "L". Stop turning the knob when both
LIGHT INCIDENT and STABILITY indicators light. This is
the proper distance setting.
5. Next, adjust the sensitivity.
1. Set sensitivity adjuster to center position.
2. Turn the distance adjusting knob fully counterclockwise,
for as many turns as necessary, to reach the longest
distance setting "L".
3. Remove the object to be detected, if present.
4. Turn the distance adjusting knob slowly clockwise, from
longest distance setting "L" toward the shortest distance
setting "S". Watch for the following combination of
indicators to light:
E3S-LS10: Stop turning the knob when both LIGHT
INCIDENT and STABILITY indicators light.
E3S-LS20: Stop turning the knob just before the
STABILITY indicator goes out while the
LIGHT INCIDENT indicator is lit.
5. Next, adjust the sensitivity.
Distance adjusting knob
Detected
object
Background
object
■ SENSITIVITY ADJUSTMENT