www.saia-burgess.com
saia-burgess Switches
F5
Operating Characteristics
Actuating Release Free Operating Movement Over
Actuator Reference Force Force Position Position Differential travel
Maximum Minimum Maximum Maximum
(N) (ozf) (N) (ozf) (mm) (in) (mm) (in) (mm) (in)
Plunger
F5T8 1,4 5,00 0,25 0,90 9.5 0,37 8,75 ± 0,3 0,34 ± 0,012 0,13 0,005 *
Y1-Lever
F5T8Y1 0,6 2,20 0,07 0,25 10,7 0,42 8,8 ± 1,1 0,35 ± 0,04 0,70 0,030 *
Width of lever 3.0 mm/0.12 in
YC-Lever
F5T8YC 0,7 2,50 0,09 0,32 12.4 0,49 10,9 ± 0.85 0,43 ± 0,03 0,45 0,020 *
Width of lever 3.0 mm/0.12 in
Operating characteristics are specified from the terminal shoulder.
* Plunger can be depressed flush with housing. The housing should not be used as an end stop.
R2.4
Burgess
Burgess
Burgess
[0.09]
[0.83]
[0.3]
7.5
16.9
[0.67]
[0.3]
21.0
7.5
[0.06]
1.6
[0.13]
3.4
R2.4
Burgess
Burgess
Burgess
[0.09]
[0.83]
[0.3]
7.5
16.9
[0.67]
[0.3]
21.0
7.5
[0.06]
1.6
[0.13]
3.4
R2.4
Burgess
Burgess
Burgess
[0.09]
[0.83]
[0.3]
7.5
16.9
[0.67]
[0.3]
21.0
7.5
[0.06]
1.6
[0.13]
3.4
Basic type F5
Terminals
T8 PCB 1.27 0.5 3.0 long
Circuit
No symbol, change-over
C2 Normally closed
C4 Normally open
Actuators
No symbol, without lever
Y1 Plain lever 21.0 mm
YC Cam follower lever 16.9 mm
Contact Material
No symbol, Ag
GP Gold plate on Ag (GP)
Approvals
No symbol, without approval
UL UL and CSA approval
Special Features / Saia-Burgess specialise in customer specific solutions.
Additional product variants are available or can be provided.
If your requirements cannot be satisfied from the options listed,
please contact www.saia-burgess.com or your local SB outlet.
Type coding key for standard products
Example: F5 T8 C2 Y1 GP UL
22 | 23