Model 13 Subminiature Load Cell DESCRIPTION Model 13 (compression only) subminiature load cell is designed frequency response and low deflection to achieve a combined to measure load ranges from 150 g to 1000 lb. With subminiature non-linearity and hysteresis of 0.25 % to 0.5 % full scale. A dimensions, including diameters from 0.38 in to 0.75 in and balance module is included in the load cell's lead wire cable for heights of 0.13 in to 0.25 in, these units are easily incorporated temperature compensation and should not be removed. into systems having limited space. Model 13 combines high FEATURES * 150 g to 1000 lb * 0.7 % accuracy * mV/V output * Subminiature design * Single diaphragm construction Model 13 PERFORMANCE SPECIFICATIONS RANGE CODES Characteristic Measure Range codes Range Load ranges6 150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb AL 150 g AN 250 g Linearity 0.5 % full scale AP 500 g Hysteresis 0.5 % full scale AR 1000 g Non-repeatability 0.1 % full scale AT 5 lb Tolerance on output 150 g to 500 g 15 mV/V (nominal) AV 10 lb Tolerance on output 1000 g 1.5 mV/V (nominal) BL 25 lb Tolerance on output 5 lb to 1000 lb BN 50 lb 2 mV/V (nominal) BR 100 lb Operation Compression only CN 250 lb Resolution Infinite CR 500 lb CV 1000 lb ENVIRONMENTAL SPECIFICATIONS WIRING CODES Characteristic Measure Temperature, operating -54 C to 121 C [-65 F to 250 F] Cable Unamplified Temperature, compensated 15 C to 71 C [60 F to 160 F] Red (+) excitation Temperature effect, zero 0.01 % full scale/F Black (-) excitation Temperature effect, span 0.02 % reading/F Green (-) output White (+) output ELECTRICAL SPECIFICATIONS Characteristic Measure Strain gage type 150 g to 500 g Semiconductor Strain gage type 1000 g to 1000 lb Bonded foil Excitation (calibration) 5 Vdc Insulation resistance 5000 mOhm @ 50 Vdc Bridge resistance (tolerance)150 g to 500 g 500 ohm (nominal) Bridge resistance (tolerance)1000 g to 1000 lb 350 ohm (nominal) Zero balance (tolerance) DEFLECTIONS AND RINGING FREQUENCIES Capacity (lb) Deflection at full scale (10-3 in) Weight Weight with cable Max. allowable load1 (% FS) 150 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500 250 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500 500 g 0.08 1 g [0.002 lb] 9 g [0.019 lb] 500 1000 g 0.05 1 g [0.002 lb] 9 g [0.019 lb] 150 5 lb 0.5 1 g [0.002 lb] 9 g [0.019 lb] 150 10 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150 3 % of full scale (nominal) 25 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150 Shunt calibration data Included 50 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150 Electrical termination (std) 1,83 m [5 ft] integral cable with balance board3 100 lb 0.4 3 g [0.006 lb] 11 g [0.024 lb] 150 250 lb 0.5 3 g [0.006 lb] 11 g [0.024 lb] 150 500 lb 0.5 10 g [0.022 lb] 18 g [0.039 lb] 150 1000 lb 0.6 10 g [0.022 lb] 18 g [0.039 lb] 150 MECHANICAL SPECIFICATIONS Characteristic Measure Maximum allowable load See table Weight See table Material Stainless steel Deflection @ full scale See table 2 Honeywell * Sensing and Control Subminiature Load Cell MOUNTING DIMENSIONS Ranges D1 D2 H B SR 150, 250, 500, 1000 g; 5, 10, 25, 50 lb 2,29 mm [0.09 in] 9,65 mm [0.38 in] 3,3 mm [0.13 in] 0,69 mm [0.027 in] 6,35 mm [0.25 in] 100, 250 lb 3,05 mm [0.12] 12,7 mm [0.50 in] 3,81 mm [0.15 in] 0,51 mm [0.020 in] 12,7 mm [0.50 in] 500 lb, 1000 lb 6,35 mm [0.25 in] 19,05 mm [0.75] 6,35 mm [0.25 in] 0,64 mm [0.025 in] 12,7 mm [0.50 in] OPTION CODES Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Load range 150, 250, 500 g, 1000 g; 5, 10, 25, 50, 100, 250, 500, 1000 lb Temperature 1a. 60 F to 160 F 1b. 30 F to 130 F compensa1c. 0 F to 185 F tion 1d. -20 F to 200 F TYPICAL SYSTEM DIAGRAM 1e. -20 F to 200 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 to 110 C Internal amplifiers 2u. Unamplified, mV/V output Overload stops 4a. Overload stops Electrical termination 5 ft integral cable with balance board3 6v. Phoenix connector on end of cable 15d. Connector on end of cable Special calibration 9a. 10 point (5 up/5 down) 20 % increments @ 68 F 9b. 20 point (10 up/10 down) 10 % increments @ 68 F Shock and vibration 44a. Shock and vibration resistance Honeywell * Sensing and Control 3 Model 13 Subminiature Load Cell NOTES 1. 2. 3. 4. 5. 6. Allowable maximum loads - maximum load to be applied without damage.2 Loads described allow for 100 % full scale axial loading with the bending loads specified. Torque loading maximum is without axial or other load. For any other combination, consult factory. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. A small, 2 in circuit board is included in the cable, 2 ft from the load cell. Do not remove this board. Only for ranges greater-than-or-equal-to 1000 g. Specifications may vary with this option. This unit calibrated to Imperial (non-Metric) units. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifica- * The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. tions, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell's test and measurement products, call +1-614-850-5000, visit www.honeywell.com/sensotec, or e-mail inquiries to info.tm@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008641-2-EN IL50 GLO April 2009 Copyright (c) 2009 Honeywell International Inc. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: 060-2444-03 060-2443-08 060-2445-04 060-2443-02 060-2443-07 060-2444-06 060-2443-06