IDT72261LA
IDT72271LA
CMOS SuperSync FIFO
16,384 x 9
32,768 x 9
FEATURES:
Choose among the following memory organizations:
IDT72261LA 16,384 x 9
IDT72271LA 32,768 x 9
Pin-compatible with the IDT72281/72291 SuperSync FIFOs
10ns read/write cycle time (8ns access time)
Fixed, low first word data latency time
Auto power down minimizes standby power consumption
Master Reset clears entire FIFO
Partial Reset clears data, but retains programmable settings
Retransmit operation with fixed, low first word data latency time
Empty, Full and Half-Full flags signal FIFO status
Programmable Almost-Empty and Almost-Full flags, each flag
can default to one of two preselected offsets
Program partial flags by either serial or parallel means
Select IDT Standard timing (using EF and FF flags) or First
Word Fall Through timing (using OR and IR flags)
Output enable puts data outputs into high impedance state
Easily expandable in depth and width
Independent Read and Write clocks (permit reading and writing
simultaneously)
FUNCTIONAL BLOCK DIAGRAM
INPUT REGISTER
OUTPUT REGISTER
RAM ARRAY
16,384 x 9
32,768 x 9
FLAG
LOGIC
FF/IR
PAF
EF/OR
PAE
HF
READ POINTER
READ
CONTROL
LOGIC
WRITE CONTROL
LOGIC
WRITE POINTER
RESET
LOGIC
WEN WCLK D
0
-D
8
LD
MRS
REN
RCLK
OE Q
0
-Q
8
OFFSET REGISTER
PRS
FWFT/SI
SEN
RT
4671 drw 01
Available in the 64-pin Thin Quad Flat Pack (TQFP) and the 64-
pin Slim Thin Quad Flat Pack (STQFP)
High-performance submicron CMOS technology
Industrial temperature range (–40°C to +85°C) is available
Green parts available, see ordering information
DESCRIPTION:
The IDT72261LA/72271LA are exceptionally deep, high speed, CMOS
First-In-First-Out (FIFO) memories with clocked read and write controls.
These FIFOs offer numerous improvements over previous SuperSync
FIFOs, including the following:
The limitation of the frequency of one clock input with respect to the other
has been removed. The Frequency Select pin (FS) has been removed,
thus it is no longer necessary to select which of the two clock inputs,
RCLK or WCLK, is running at the higher frequency.
The period required by the retransmit operation is now fixed and short.
The first word data latency period, from the time the first word is written
to an empty FIFO to the time it can be read, is now fixed and short. (The
variable clock cycle counting delay associated with the latency period found
on previous SuperSync devices has been eliminated on this SuperSync
family.)
2
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
PIN CONFIGURATIONS
TQFP (PN64-1, ORDER CODE: PF)
STQFP (PP64-1, ORDER CODE: TF)
TOP VIEW
DESCRIPTION (CONTINUED)
PIN 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
WEN
SEN
DC(1)
VCC
VCC
GND(2)
GND(2)
GND(2)
GND(2)
GND(2)
GND(2)
GND(2)
GND(2)
GND(2)
D8
D7
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
DNC(3)
DNC(3)
GND
DNC(3)
DNC(3)
VCC
DNC(3)
DNC(3)
DNC(3)
GND
DNC(3)
DNC(3)
Q8
Q7
Q6
GND
WCLK
PRS
MRS
LD
FWFT/SI
GND
FF/IR
PAF
HF
VCC
PAE
EF/OR
RCLK
REN
RT
OE
Q5
Q4
VCC
Q3
Q2
GND
Q1
Q0
GND
D0
D1
D2
D3
D4
D5
D6
4671 drw 02
NOTES:
1. DC = Don’t Care. Must be tied to GND or VCC, cannot be left open.
2. This pin may either be tied to ground or left open.
3. DNC = Do Not Connect.
SuperSync FIFOs are particularly appropriate for network, video, telecom-
munications, data communications and other applications that need to buffer
large amounts of data.
The input port is controlled by a Write Clock (WCLK) input and a Write Enable
(WEN) input. Data is written into the FIFO on every rising edge of WCLK when
WEN is asserted. The output port is controlled by a Read Clock (RCLK) input
and Read Enable (REN) input. Data is read from the FIFO on every rising
edge of RCLK when REN is asserted. An Output Enable (OE) input is provided
for three-state control of the outputs.
The frequencies of both the RCLK and the WCLK signals may vary from 0
to fMAX with complete independence. There are no restrictions on the
frequency of one clock input with respect to the other.
There are two possible timing modes of operation with these devices:
IDT Standard mode and First Word Fall Through (FWFT) mode.
In IDT Standard mode, the first word written to an empty FIFO will not
appear on the data output lines unless a specific read operation is
performed. A read operation, which consists of activating REN and enabling
a rising RCLK edge, will shift the word from internal memory to the data output
lines.
3
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
DESCRIPTION (CONTINUED)
Figure 1. Block Diagram of Single 16,384 x 9 and 32,768 x 9 Synchronous FIFO
DATA OUT (Q
0
- Q
n
)
DATA IN (D
0
- D
n
)
MASTER RESET (MRS)
READ CLOCK (RCLK)
READ ENABLE (REN)
OUTPUT ENABLE (OE)
EMPTY FLAG/OUTPUT READY (EF/OR)
PROGRAMMABLE ALMOST-EMPTY (PAE)
WRITE CLOCK (WCLK)
WRITE ENABLE (WEN)
LOAD (LD)
FULL FLAG/INPUT READY (FF/IR)
PROGRAMMABLE ALMOST-FULL (PAF)
IDT
72261LA
72271LA
PARTIAL RESET (PRS)
FIRST WORD FALL THROUGH/SERIAL INPUT
(FWFT/SI)
RETRANSMIT (RT)
4671 drw 03
HALF FULL FLAG (HF)
SERIAL ENABLE(SEN)
In FWFT mode, the first word written to an empty FIFO is clocked directly
to the data output lines after three transitions of the RCLK signal. A REN
does not have to be asserted for accessing the first word. However,
subsequent words written to the FIFO do require a LOW on REN for
access. The state of the FWFT/SI input during Master Reset determines
the timing mode in use.
For applications requiring more data storage capacity than a single
FIFO can provide, the FWFT timing mode permits depth expansion by
chaining FIFOs in series (i.e. the data outputs of one FIFO are connected
to the corresponding data inputs of the next). No external logic is required.
These FIFOs have five flag pins, EF/OR (Empty Flag or Output Ready),
FF/IR (Full Flag or Input Ready), HF (Half-full Flag), PAE (Programmable
Almost-Empty flag) and PAF (Programmable Almost-Full flag). The EF
and FF functions are selected in IDT Standard mode. The IR and OR
functions are selected in FWFT mode. HF, PAE and PAF are always
available for use, irrespective of timing mode.
PAE and PAF can be programmed independently to switch at any point
in memory. (See Table I and Table II.) Programmable offsets determine
the flag switching threshold and can be loaded by two methods: parallel or
serial. Two default offset settings are also provided, so that PAE can be
set to switch at 127 or 1,023 locations from the empty boundary and the
PAF threshold can be set at 127 or 1,023 locations from the full boundary.
These choices are made with the LD pin during Master Reset.
For serial programming, SEN together with LD on each rising edge of
WCLK, are used to load the offset registers via the Serial Input (SI). For
parallel programming, WEN together with LD on each rising edge of WCLK,
are used to load the offset registers via Dn. REN together with LD on each rising
edge of RCLK can be used to read the offsets in parallel from Qn regardless
of whether serial or parallel offset loading has been selected.
During Master Reset (MRS) the following events occur: The read and write
pointers are set to the first location of the FIFO. The FWFT pin selects IDT
Standard mode or FWFT mode. The LD pin selects either a partial flag default
setting of 127 with parallel programming or a partial flag default setting of 1,023
with serial programming. The flags are updated according to the timing mode
and default offsets selected.
The Partial Reset (PRS) also sets the read and write pointers to the first
location of the memory. However, the timing mode, partial flag program-
ming method, and default or programmed offset settings existing before
Partial Reset remain unchanged. The flags are updated according to the
timing mode and offsets in effect. PRS is useful for resetting a device in
mid-operation, when reprogramming partial flags would be undesirable.
The Retransmit function allows data to be reread from the FIFO more
than once. A LOW on the RT input during a rising RCLK edge initiates a
retransmit operation by setting the read pointer to the first location of the
memory array.
If, at any time, the FIFO is not actively performing an operation, the chip
will automatically power down. Once in the power down state, the standby
supply current consumption is minimized. Initiating any operation (by
activating control inputs) will immediately take the device out of the power
down state.
The IDT72261LA/72271LA are fabricated using IDT’s high speed sub-
micron CMOS technology.
4
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Symbol Name I/O Description
D0–D8Data Inputs I Data inputs for a 9-bit bus.
MRS Master Reset I MRS initializes the read and write pointers to zero and sets the output register to all zeroes.
During Master Reset, the FIFO is configured for either FWFT or IDT Standard mode, one of
two programmable flag default settings, and serial or parallel programming of the offset settings.
PRS Partial Reset I PRS initializes the read and write pointers to zero and sets the output method (serial or parallel),
and programmable flag settings are all retained.
RT Retransmit I RT asserted on the rising edge of RCLK initializes the READ pointer to zero, sets
the EF flag to
LOW (OR to HIGH in FWFT mode) temporarily and does not disturb the write pointer, programming
method, existing timing mode or programmable flag settings. RT is useful to reread data from the
first physical location of the FIFO.
FWFT/SI First Word Fall I During Master Reset, selects First Word Fall Through or IDT Standard mode. Through/Serial
In After Master Reset, this pin functions as a serial input for loading offset registers
WCLK Write Clock I When enabled by WEN, the rising edge of WCLK writes data into the FIFO and offsets into
the programmable registers for parallel programming, and when enabled by SEN, the rising
edge of WCLK writes one bit of data into the programmable register for serial programming.
WEN Write Enable I WEN enables WCLK for writing data into the FIFO memory and offset registers.
RCLK Read Clock I When enabled by REN, the rising edge of RCLK reads data from the FIFO memory and offsets
from the programmable registers.
REN Read Enable I REN enables RCLK for reading data from the FIFO memory and offset registers.
OE Output Enable I OE controls the output impedance of Qn.
SEN Serial Enable I SEN enables serial loading of programmable flag offsets.
LD Load I During Master Reset, LD selects one of two partial flag default offsets (127 or
1,023) and determines
the flag offset programming method, serial or parallel. After
Master Reset, this pin enables writing to
and reading from the offset registers.
DC Don't Care I This pin must be tied to either VCC or GND and must not toggle after Master Reset.
FF/IR Full Flag/ O In the IDT Standard mode, the FF function is selected. FF indicates whether or not the FIFO memory
Input Ready is full. In the FWFT mode, the IR function is selected. IR indicates whether or not there is space
available for writing to the FIFO memory.
EF/OR Empty Flag/ O In the IDT Standard mode, the EF function is selected. EF indicates whether or not the FIFO memory
Output Ready is empty. In FWFT mode, the OR function is selected. OR indicates whether or not there is valid data
available at the outputs.
PAF Programmable O PAF goes LOW if the number of words in the FIFO memory is more than word capacity of the FIFO
Almost-Full Flag minus the full offset value m, which is stored in the Full Offset register. There are two possible default
values for m: 127 or 1,023.
PAE Programmable O PAE goes LOW if the number of words in the FIFO memory is less than offset n, which is stored in the
Almost-Empty Flag Empty Offset register. There are two possible default values for n: 127 or 1,023. Other values for n
can be programmed into the device.
HF Half-Full Flag O HF indicates whether the FIFO memory is more or less than half-full.
Q0–Q8Data Outputs O Data outputs for a 9-bus
VCC Power +5 Volt power supply pins.
GND Ground Ground pins.
PIN DESCRIPTION
5
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Symbol Parameter Min. Typ. Max. Unit
VCC Supply Voltage 4.5 5.0 5.5 V
Commercial/Industrial
GND Supply Voltage 0 0 0 V
VIH Input High Voltage 2.0 V
Commercial/Industrial
VIL(1) Input Low Voltage 0.8 V
Commercial/Industrial
TA Operating Temperature 0 +70 °C
Commercial
TA Operating Temperature 40 +85 °C
Industrial
Symbol Rating Com’l & Ind’l Unit
VTERM Terminal Voltage –0.5 to +7 V
with respect to GND
TSTG Storage –55 to +125 °C
Temperature
IOUT DC Output Current –50 to +50 mA
NOTES:
1. With output deselected, (OE VIH).
2. Characterized values, not currently tested.
DC ELECTRICAL CHARACTERISTICS
(Commercial: VCC = 5V ± 10%, TA = 0°C to +70°C; In dustr ial: VCC = 5V ± 10%, T A = – 40°C to +85°C)
Symbol Parameter(1) Conditions Max. Unit
CIN(2) Input VIN = 0V 10 pF
Capacitance
COUT(1,2) Output VOUT = 0V 10 pF
Capacitance
NOTE:
1.5V undershoots are allowed for 10ns once per cycle.
IDT72261LA
IDT72271LA
Commercial and Industrial(1)
tCLK = 10, 15, 20 ns
Symbol Parameter Min. Max. Unit
ILI(2) Input Leakage Current 1 1 µA
ILO(3) Output Leakage Current 10 10 µA
VOH Output Logic “1” Voltage, IOH = –2 mA 2 .4 V
VOL Output Logic “0” Voltage, IOL = 8 mA 0 .4 V
ICC1(4,5,6) Active Power Supply Current 75 mA
ICC2(4,7) Standby Current 20 mA
NOTES:
1. Industrial temperature range product for the 15ns and 20ns speed grade are available as a standard device.
2. Measurements with 0.4 VIN VCC.
3. OE VIH, 0.4 VOUT VCC.
4. Tested with outputs disabled (IOUT = 0).
5. RCLK and WCLK toggle at 20 MHz and data inputs switch at 10 MHz.
6. Typical ICC1 = 15 + 1.85*fS + 0.02*CL*fS (in mA) with VCC = 5V, tA = 25°C, fS = WCLK frequency = RCLK frequency (in MHz, using TTL levels), data switching at fS/2,
CL = capacitive load (in pF).
7. All Inputs = VCC - 0.2V or GND + 0.2V, except RCLK and WCLK, which toggle at 20 MHz.
ABSOLUTE MAXIMUM RATINGS
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
RECOMMENDED DC OPERATING
CONDITIONS
CAPACITANCE
(TA = +25°C, f = 1.0MHz)
6
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
4671 drw 04
1.1K
30pF*
680
5V
D.U.T.
Commercial Commercial & Industrial(2)
IDT72261LA10 IDT72261LA15 IDT72261LA20
IDT72271LA10 IDT72271LA15 IDT72271LA20
Symbol Parameter Min. Max. Min. Max. Min. Max. Unit
fSClock Cycle Frequency 100 66.7 50 MHz
tAData Access Time 2 8 2 1 0 2 1 2 ns
tCLK Clock Cycle Time 10 15 20 ns
tCLKH Clock High Time 4 .5 6 8 n s
tCLKL Clock Low Time 4 .5 6 8 ns
tDS Data Setup Time 3 4 5 ns
tDH Data Hold Time 0 1 1 ns
tENS Enable Setup Time 3 4 5 ns
tENH Enable Hold Time 0 1 1 ns
tLDS Load Setup Time 3 4 5 ns
tLDH Load Hold Time 0 1 1 ns
tRS Reset Pulse Width(3) 10 15 20 ns
tRSS Reset Setup Time 10 15 20 ns
tRSR Reset Recovery Time 10 1 5 2 0 ns
tRSF Reset to Flag and Output Time 10 15 2 0 ns
tFWFT Mode Select Time 0 0 0 ns
tRTS Retransmit Setup Time 3 4 5 ns
tOLZ Output Enable to Output in Low Z(4) 0 —0— 0—ns
tOE Output Enable to Output Valid 2 6 3 8 3 10 ns
tOHZ Output Enable to Output in High Z(4) 2 638 310ns
tWFF Write Clock to FF or IR —81012ns
tREF Read Clock to EF or OR —81012ns
tPAF Write Clock to PAF —81012ns
tPAE Read Clock to PAE —81012ns
tHF Clock to HF —1620—22ns
tSKEW1 Skew time between RCLK and WCLK for FF/IR 5—610ns
tSKEW2 Skew time between RCLK and WCLK for PAE and PAF 12 15 20 ns
tSKEW3 Skew time between RCLK and WCLK for EF/OR 60 60 60 ns
tSKEW4 Skew time between RCLK and WCLK for PAE and PAF 15 17 25 ns
for Re-transmit operation
AC ELECTRICAL CHARACTERISTICS(1)
(Commercial: VCC = 5V ± 10%, TA = 0°C to +70°C; In dustr ial: VCC = 5V ± 10%, T A = – 40°C to +85°C)
NOTES:
1. All AC timings apply to both Standard IDT mode and First Word Fall Through mode.
2. Industrial temperature range product for 15ns and 20ns speed grades are available as a standard device.
3. Pulse widths less than minimum values are not allowed.
4. Values guaranteed by design, not currently tested.
Input Pulse Levels GND to 3.0V
Input Rise/Fall Times 3ns
Input Timing Reference Levels 1.5V
Output Reference Levels 1.5V
Output Load See Figure 1
AC TEST CONDITIONS
Figure 2. Output Load
* Includes jig and scope capacitances.
7
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
If the FIFO is full, the first read operation will cause FF to go HIGH.
Subsequent read operations will cause PAF and HF to go HIGH at the
conditions described in Table 1. If further read operations occur, without
write operations, PAE will go LOW when there are n words in the FIFO,
where n is the empty offset value. Continuing read operations will cause
the FIFO to become empty. When the last word has been read from the
FIFO, the EF will go LOW inhibiting further read operations. REN is ignored
when the FIFO is empty.
When configured in IDT Standard mode, the EF and FF outputs are
double register-buffered outputs.
Relevant timing diagrams for IDT Standard mode can be found in Figure
7, 8 and 11.
FIRST WORD FALL THROUGH MODE (FWFT)
In this mode, the status flags, IR, PAF, HF, PAE, and OR operate in the
manner outlined in Table 2. To write data into to the FIFO, WEN must be
LOW. Data presented to the DATA IN lines will be clocked into the FIFO
on subsequent transitions of WCLK. After the first write is performed, the
Output Ready (OR) flag will go LOW. Subsequent writes will continue to fill
up the FIFO. PAE will go HIGH after n + 2 words have been loaded into the
FIFO, where n is the empty offset value. The default setting for this value
is stated in the footnote of Table 2. This parameter is also user program-
mable. See section on Programmable Flag Offset Loading.
If one continued to write data into the FIFO, and we assumed no read
operations were taking place, the HF would toggle to LOW once the
8,194th word for the IDT72261LA and 16,386th word for the IDT72271LA,
respectively was written into the FIFO. Continuing to write data into the
FIFO will cause the PAF to go LOW. Again, if no reads are performed, the
PAF will go LOW after (16,385-m) writes for the IDT72261LA and (32,769-
m) writes for the IDT72271LA, where m is the full offset value. The default
setting for this value is stated in the footnote of Table 2.
When the FIFO is full, the Input Ready (IR) flag will go HIGH, inhibiting
further write operations. If no reads are performed after a reset, IR will go
HIGH after D writes to the FIFO. D = 16,385 writes for the 72261LA and
32,769 writes for the IDT72271LA, respectively. Note that the additional
word in FWFT mode is due to the capacity of the memory plus output
register.
If the FIFO is full, the first read operation will cause the IR flag to go LOW.
Subsequent read operations will cause the PAF and HF to go HIGH at the
conditions described in Table 2. If further read operations occur, without
write operations, the PAE will go LOW when there are n + 1 words in the
FIFO, where n is the empty offset value. Continuing read operations will
cause the FIFO to become empty. When the last word has been read from
the FIFO, OR will go HIGH inhibiting further read operations. REN is
ignored when the FIFO is empty.
When configured in FWFT mode, the OR flag output is triple register-
buffered, and the IR flag output is double register-buffered.
Relevant timing diagrams for FWFT mode can be found in Figure 9, 10
and 12.
FUNCTIONAL DESCRIPTION
TIMING MODES: IDT STANDARD VS FIRST WORD FALL THROUGH
(FWFT) MODE
The IDT72261LA/72271LA support two different timing modes of opera-
tion: IDT Standard mode or First Word Fall Through (FWFT) mode. The
selection of which mode will operate is determined during Master Reset,
by the state of the FWFT/SI input.
If, at the time of Master Reset, FWFT/SI is LOW, then IDT Standard
mode will be selected. This mode uses the Empty Flag (EF) to indicate
whether or not there are any words present in the FIFO. It also uses the Full
Flag function (FF) to indicate whether or not the FIFO has any free space
for writing. In IDT Standard mode, every word read from the FIFO,
including the first, must be requested using the Read Enable (REN) and
RCLK.
If, at the time of Master Reset, FWFT/SI is HIGH, then FWFT mode will
be selected. This mode uses Output Ready (OR) to indicate whether or not
there is valid data at the data outputs (Qn). It also uses Input Ready (IR)
to indicate whether or not the FIFO has any free space for writing. In the
FWFT mode, the first word written to an empty FIFO goes directly to Qn
after three RCLK rising edges, REN = LOW is not necessary. Subsequent
words must be accessed using the Read Enable (REN) and RCLK.
Various signals, both input and output signals operate differently de-
pending on which timing mode is in effect.
IDT STANDARD MODE
In this mode, the status flags, FF, PAF, HF, PAE, and EF operate in the
manner outlined in Table 1. To write data into to the FIFO, Write Enable
(WEN) must be LOW. Data presented to the DATA IN lines will be clocked
into the FIFO on subsequent transitions of the Write Clock (WCLK). After
the first write is performed, the Empty Flag (EF) will go HIGH. Subsequent
writes will continue to fill up the FIFO. The Programmable Almost-Empty
flag (PAE) will go HIGH after n + 1 words have been loaded into the FIFO,
where n is the empty offset value. The default setting for this value is stated
in the footnote of Table 1. This parameter is also user programmable. See
section on Programmable Flag Offset Loading.
If one continued to write data into the FIFO, and we assumed no read
operations were taking place, the Half-Full flag (HF) would toggle to LOW
once the 8,193th word for IDT72261LA and 16,385th word for IDT72271LA
respectively was written into the FIFO. Continuing to write data into the
FIFO will cause the Programmable Almost-Full flag (PAF) to go LOW.
Again, if no reads are performed, the PAF will go LOW after (16,384-m)
writes for the IDT72261LA and (32,768-m) writes for the IDT72271LA. The
offset “m” is the full offset value. The default setting for this value is stated
in the footnote of Table 1. This parameter is also user programmable. See
section on Programmable Flag Offset Loading.
When the FIFO is full, the Full Flag (FF) will go LOW, inhibiting further
write operations. If no reads are performed after a reset, FF will go LOW
after D writes to the FIFO. D = 16,384 writes for the IDT72261LA and
32,768 for the IDT72271LA, respectively.
8
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
NOTES:
1. n = Empty Offset, Default Values: n = 127 when parallel offset loading is selected or n = 1,023 when serial offset loading is selected.
2. m = Full Offset, Default Values: m = 127 when parallel offset loading is selected or m = 1,023 when serial offset loading is selected.
PROGRAMMING FLAG OFFSETS
Full and Empty Flag offset values are user programmable. The
IDT72261LA/72271LA has internal registers for these offsets. Default
settings are stated in the footnotes of Table 1 and Table 2. Offset values
can be programmed into the FIFO in one of two ways; serial or parallel
loading method. The selection of the loading method is done using the LD
(Load) pin. During Master Reset, the state of the LD input determines
whether serial or parallel flag offset programming is enabled. A HIGH on
LD during Master Reset selects serial loading of offset values and in
addition, sets a default PAE offset value of 3FFH (a threshold 1,023 words
from the empty boundary), and a default PAF offset value of 3FFH (a
threshold 1,023 words from the full boundary). A LOW on LD during Master
Reset selects parallel loading of offset values, and in addition, sets a
default PAE offset value of 07FH (a threshold 127 words from the empty
boundary), and a default PAF offset value of 07FH (a threshold 127 words
from the full boundary). See Figure 3, Offset Register Location and Default
Values.
In addition to loading offset values into the FIFO, it also possible to read
the current offset values. It is only possible to read offset values via parallel
read.
Figure 4, Programmable Flag Offset Programming Sequence, summa-
rizes the control pins and sequence for both serial and parallel program-
ming modes. For a more detailed description, see discussion that follows.
The offset registers may be programmed (and reprogrammed) any time
after Master Reset, regardless of whether serial or parallel programming
has been selected.
Number of
Words in
FIFO
0
1 to n
(1)
0
1 to n
(1)
(n+1) to 8,192
8,193 to (16,384-(m+1))
(16,384-m)
(2)
to 16,383
16,384
IDT72261LA IDT72271LA FF PAF HF PAE EF
HHHL L
HHHL H
HHHH H
HHLH H
HLLHH
LLLHH
4671 drw 05
0
1 to n+1
(1)
0
1 to n+1
(1)
(n+2) to 16,385
16,386 to (32,769-(m+1))
(32,769-m)
(2)
to 32,768
32,769
IR PAF HF PAE OR
LHHLH
LHHLL
LHHHL
LHL HL
LLL HL
HL L H L
IDT72261LA IDT72271LA
Number of
Words in
FIFO (
1)
(n+1) to 16,384
16,385 to (32,768-(m+1))
(32,768-m)
(2)
to 32,767
32,768
(n+2) to 8,193
8,194 to (16,385-(m+1))
(16,385-m)
(2)
to 16,384
16,385
NOTES:
1. n = Empty Offset, Default Values: n = 127 when parallel offset loading is selected or n = 1,023 when serial offset loading is selected.
2. m = Full Offset, Default Values: m = 127 when parallel offset loading is selected or m = 1,023 when serial offset loading is selected.
TABLE 1 — STATUS FLAGS FOR IDT STANDARD MODE
TABLE 2 — STATUS FLAGS FOR IDT STANDARD MODE
9
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 4. Programmable Flag Offset Programming Sequence
Figure 3. Offset Register Location and Default Values
EMPTY OFFSET (LSB) REG.
870
EMPTY OFFSET (MSB) REG.
00H
85 0
IDT72261LA 16,384 x 9 BIT
FULL OFFSET (LSB) REG.
870
FULL OFFSET (MSB) REG.
00H
85 0
DEFAULT VALUE
07FH if LD is LOW at Master Reset
3FFH if LD is HIGH at Master Reset
DEFAULT VALUE
07FH if LD is LOW at Master Reset
3FFH if LD is HIGH at Master Reset
4671 drw 06
IDT72271LA 32,768 x 9 BIT
EMPTY OFFSET (LSB) REG.
870
EMPTY OFFSET (MSB) REG.
00H
86 0
FULL OFFSET (LSB) REG.
870
FULL OFFSET (MSB) REG.
00H
86 0
DEFAULT VALUE
07FH if LD is LOW at Master Reset
3FFH if LD is HIGH at Master Reset
DEFAULT VALUE
07FH if LD is LOW at Master Reset
3FFH if LD is HIGH at Master Reset
NOTES:
1. The programming method can only be selected at Master Reset.
2. Parallel reading of the offset registers is always permitted regardless of which programming method has been selected.
3. The programming sequence applies to both IDT Standard and FWFT modes.
WCLK RCLK Selection
X Parallel write to registers:
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
X Parallel read from registers:
Empty Offset (LSB)
Empty Offset (MSB)
Full Offset (LSB)
Full Offset (MSB)
X X No Operation
X Write Memory
X Read Memory
X X No Operation
4671 drw 07
LD
0
0
X
1
1
1
0
WEN
0
1
1
0
X
1
1
REN
1
0
1
X
0
1
1XSerial shift into registers:
28 bits for the 72261LA
SEN
1
1
1
X
X
X
0
30 bits for the 72271LA
1 bit for each rising WCLK edge
Starting with Empty Offset (LSB)
Ending with Full Offset (MSB)
10
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
SERIAL PROGRAMMING MODE
If Serial Programming mode has been selected, as described above,
then programming of PAE and PAF values can be achieved by using a
combination of the LD, SEN, WCLK and SI input pins. Programming PAE
and PAF proceeds as follows: when LD and SEN are set LOW, data on
the SI input are written, one bit for each WCLK rising edge, starting with
the Empty Offset LSB and ending with the Full Offset MSB. A total of 28
bits for the IDT72261LA and 30 bits for the IDT72271LA. See Figure 13,
Serial Loading of Programmable Flag Registers, for the timing diagram for
this mode.
Using the serial method, individual registers cannot be programmed
selectively. PAE and PAF can show a valid status only after the complete
set of bits (for all offset registers) has been entered. The registers can be
reprogrammed as long as the complete set of new offset bits is entered.
When LD is LOW and SEN is HIGH, no serial write to the registers can
occur.
Write operations to the FIFO are allowed before and during the serial
programming sequence. In this case, the programming of all offset bits
does not have to occur at once. A select number of bits can be written to
the SI input and then, by bringing LD and SEN HIGH, data can be written
to FIFO memory via Dn by toggling WEN. When WEN is brought HIGH
with LD and SEN restored to a LOW, the next offset bit in sequence is
written to the registers via SI. If an interruption of serial programming is
desired, it is sufficient either to set LD LOW and deactivate SEN or to set
SEN LOW and deactivate LD. Once LD and SEN are both restored to a
LOW level, serial offset programming continues.
From the time serial programming has begun, neither partial flag will be
valid until the full set of bits required to fill all the offset registers has been
written. Measuring from the rising WCLK edge that achieves the above
criteria; PAF will be valid after two more rising WCLK edges plus tPAF, PAE
will be valid after the next two rising RCLK edges plus tPAE plus tSKEW2.
It is not possible to read the flag offset values in a serial mode.
PARALLEL MODE
If Parallel Programming mode has been selected, as described above,
then programming of PAE and PAF values can be achieved by using a
combination of the LD, WCLK, WEN and Dn input pins. For the
IDT72261LA and the IDT72271LA, programming PAE and PAF proceeds
as follows: when LD and WEN are set LOW, data on the inputs Dn are
written into the Empty Offset LSB Register on the first LOW-to-HIGH
transition of WCLK. Upon the second LOW-to-HIGH transition of WCLK,
data are written into the Empty Offset MSB Register. Upon the third LOW-
to-HIGH transition of WCLK, data are written into the Full Offset LSB
Register. Upon the fourth LOW-to-HIGH transition of WCLK, data are
written into the Full Offset MSB Register. The fifth transition of WCLK
writes, once again, to the Empty Offset LSB Register. See Figure 14,
Parallel Loading of Programmable Flag Registers for the IDT72261LA, for
the timing diagram for this mode.
The act of writing offsets in parallel employs a dedicated write offset
register pointer. The act of reading offsets employs a dedicated read offset
register pointer. The two pointers operate independently; however, a read
and a write should not be performed simultaneously to the offset registers.
A Master Reset initializes both pointers to the Empty Offset (LSB) register.
A Partial Reset has no effect on the position of these pointers.
Write operations to the FIFO are allowed before and during the parallel
programming sequence. In this case, the programming of all offset
registers does not have to occur at one time. One, two or more offset
registers can be written and then by bringing LD HIGH, write operations
can be redirected to the FIFO memory. When LD is set LOW again, and
WEN is LOW, the next offset register in sequence is written to. As an
alternative to holding WEN LOW and toggling LD, parallel programming
can also be interrupted by setting LD LOW and toggling WEN.
Note that the status of a partial flag (PAE or PAF) output is invalid during
the programming process. From the time parallel programming has
begun, a partial flag output will not be valid until the appropriate offset word
has been written to the register(s) pertaining to that flag. Measuring from
the rising WCLK edge that achieves the above criteria; PAF will be valid
after two more rising WCLK edges plus tPAF, PAE will be valid after the next
two rising RCLK edges plus tPAE plus tSKEW2.
The act of reading the offset registers employs a dedicated read offset
register pointer. The contents of the offset registers can be read on the Q0-
Qn pins when LD is set LOW and REN is set LOW. For the IDT72261LA
and the IDT72271LA, data are read via Qn from the Empty Offset LSB
Register on the first LOW-to-HIGH transition of RCLK. Upon the second
LOW-to-HIGH transition of RCLK, data are read from the Empty Offset
MSB Register. Upon the third LOW-to-HIGH transition of RCLK, data are
read from the Full Offset LSB Register. Upon the fourth LOW-to-HIGH
transition of RCLK, data are read from the Full Offset MSB Register. The
fifth transition of RCLK reads, once again, from the Empty Offset LSB
Register. See Figure 15, Parallel Read of Programmable Flag Registers
for the IDT72261LA, for the timing diagram for this mode.
It is permissible to interrupt the offset register read sequence with reads
or writes to the FIFO. The interruption is accomplished by deasserting
REN, LD, or both together. When REN and LD are restored to a LOW level,
reading of the offset registers continues where it left off. It should be noted,
and care should be taken from the fact that when a parallel read of the flag
offsets is performed, the data word that was present on the output lines
Qn will be overwritten.
Parallel reading of the offset registers is always permitted regardless of
which timing mode (IDT Standard or FWFT modes) has been selected.
RETRANSMIT OPERATION
The Retransmit operation allows data that has already been read to be
accessed again. There are two stages: first, a setup procedure that resets
the read pointer to the first location of memory, then the actual retransmit,
which consists of reading out the memory contents, starting at the
beginning of memory.
Retransmit setup is initiated by holding RT LOW during a rising RCLK
edge. REN and WEN must be HIGH before bringing RT LOW. At least one
word, but no more than D - 2 words should have been written into the FIFO
between Reset (Master or Partial) and the time of Retransmit setup.
D = 16,384 for the IDT72261LA and D = 32,768 for the IDT72271LA in IDT
Standard mode. In FWFT mode, D = 16,385 for the IDT72261LA and D
= 32,769 for the IDT72271LA.
If IDT Standard mode is selected, the FIFO will mark the beginning of the
Retransmit setup by setting EF LOW. The change in level will only be
noticeable if EF was HIGH before setup. During this period, the internal
read pointer is initialized to the first location of the RAM array.
When EF goes HIGH, Retransmit setup is complete and read operations
may begin starting with the first location in memory. Since IDT Standard
mode is selected, every word read including the first word following
Retransmit setup requires a LOW on REN to enable the rising edge of
RCLK. See Figure 11, Retransmit Timing (IDT Standard Mode), for the
relevant timing diagram.
11
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
If FWFT mode is selected, the FIFO will mark the beginning of the
Retransmit setup by setting OR HIGH. During this period, the internal read
pointer is set to the first location of the RAM array.
When OR goes LOW, Retransmit setup is complete; at the same time,
the contents of the first location appear on the outputs. Since FWFT mode
is selected, the first word appears on the outputs, no LOW on REN is
necessary. Reading all subsequent words requires a LOW on REN to
enable the rising edge of RCLK. See Figure 12, Retransmit Timing (FWFT
Mode), for the relevant timing diagram.
For either IDT Standard mode or FWFT mode, updating of the PAE, HF
and PAF flags begin with the rising edge of RCLK that RT is setup. PAE
is synchronized to RCLK, thus on the second rising edge of RCLK after RT
is setup, the PAE flag will be updated. HF is asynchronous, thus the rising
edge of RCLK that RT is setup will update HF. PAF is synchronized to
WCLK, thus the second rising edge of WCLK that occurs tSKEW after the
rising edge of RCLK that RT is setup will update PAF. RT is synchronized
to RCLK.
12
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
SIGNAL DESCRIPTION
INPUTS:
DATA IN (D0 - D8)
Data inputs for 9-bit wide data.
CONTROLS:
MASTER RESET (MRS)
A Master Reset is accomplished whenever the MRS input is taken to a
LOW state. This operation sets the internal read and write pointers to the
first location of the RAM array. PAE will go LOW, PAF will go HIGH, and
HF will go HIGH.
If FWFT is LOW during Master Reset then the IDT Standard mode,
along with EF and FF are selected. EF will go LOW and FF will go HIGH.
If FWFT is HIGH, then the First Word Fall Through mode (FWFT), along
with IR and OR, are selected. OR will go HIGH and IR will go LOW.
If LD is LOW during Master Reset, then PAE is assigned a threshold 127
words from the empty boundary and PAF is assigned a threshold 127
words from the full boundary; 127 words corresponds to an offset value of
07FH. Following Master Reset, parallel loading of the offsets is permitted,
but not serial loading.
If LD is HIGH during Master Reset, then PAE is assigned a threshold
1,023 words from the empty boundary and PAF is assigned a threshold
1,023 words from the full boundary; 1,023 words corresponds to an offset
value of 3FFH. Following Master Reset, serial loading of the offsets is
permitted, but not parallel loading.
Parallel reading of the registers is always permitted. (See section
describing the LD pin for further details.)
During a Master Reset, the output register is initialized to all zeroes. A
Master Reset is required after power up, before a write operation can take
place. MRS is asynchronous.
See Figure 5, Master Reset Timing, for the relevant timing diagram.
PARTIAL RESET (PRS)
A Partial Reset is accomplished whenever the PRS input is taken to a
LOW state. As in the case of the Master Reset, the internal read and write
pointers are set to the first location of the RAM array, PAE goes LOW, PAF
goes HIGH, and HF goes HIGH.
Whichever mode is active at the time of Partial Reset, IDT Standard mode
or First Word Fall Through, that mode will remain selected. If the IDT Standard
mode is active, then FF will go HIGH and EF will go LOW. If the First Word
Fall Through mode is active, then OR will go HIGH, and IR will go LOW.
Following Partial Reset, all values held in the offset registers remain
unchanged. The programming method (parallel or serial) currently active
at the time of Partial Reset is also retained. The output register is initialized
to all zeroes. PRS is asynchronous.
A Partial Reset is useful for resetting the device during the course of
operation, when reprogramming partial flag offset settings may not be
convenient.
See Figure 6, Partial Reset Timing, for the relevant timing diagram.
RETRANSMIT (RT)
The Retransmit operation allows data that has already been read to be
accessed again. There are two stages: first, a setup procedure that resets
the read pointer to the first location of memory, then the actual retransmit,
which consists of reading out the memory contents, starting at the
beginning of the memory.
Retransmit setup is initiated by holding RT LOW during a rising RCLK
edge. REN and WEN must be HIGH before bringing RT LOW.
If IDT Standard mode is selected, the FIFO will mark the beginning of the
Retransmit setup by setting EF LOW. The change in level will only be
noticeable if EF was HIGH before setup. During this period, the internal
read pointer is initialized to the first location of the RAM array.
When EF goes HIGH, Retransmit setup is complete and read operations
may begin starting with the first location in memory. Since IDT Standard
mode is selected, every word read including the first word following
Retransmit setup requires a LOW on REN to enable the rising edge of
RCLK. See Figure 11, Retransmit Timing (IDT Standard Mode), for the
relevant timing diagram.
If FWFT mode is selected, the FIFO will mark the beginning of the
Retransmit setup by setting OR HIGH. During this period, the internal read
pointer is set to the first location of the RAM array.
When OR goes LOW, Retransmit setup is complete; at the same time,
the contents of the first location appear on the outputs. Since FWFT mode
is selected, the first word appears on the outputs, no LOW on REN is
necessary. Reading all subsequent words requires a LOW on REN to
enable the rising edge of RCLK. See Figure 12, Retransmit Timing (FWFT
Mode), for the relevant timing diagram.
FIRST WORD FALL THROUGH/SERIAL IN (FWFT/SI)
This is a dual purpose pin. During Master Reset, the state of the FWFT/
SI input determines whether the device will operate in IDT Standard mode
or First Word Fall Through (FWFT) mode.
If, at the time of Master Reset, FWFT/SI is LOW, then IDT Standard
mode will be selected. This mode uses the Empty Flag (EF) to indicate
whether or not there are any words present in the FIFO memory. It also
uses the Full Flag function (FF) to indicate whether or not the FIFO memory
has any free space for writing. In IDT Standard mode, every word read
from the FIFO, including the first, must be requested using the Read
Enable (REN) and RCLK.
If, at the time of Master Reset, FWFT/SI is HIGH, then FWFT mode will be
selected. This mode uses Output Ready (OR) to indicate whether or not there
is valid data at the data outputs (Qn). It also uses Input Ready (IR) to indicate
whether or not the FIFO memory has any free space for writing. In the FWFT
mode, the first word written to an empty FIFO goes directly to Qn after three
RCLK rising edges, REN = LOW is not necessary. Subsequent words must
be accessed using the Read Enable (REN) and RCLK.
After Master Reset, FWFT/SI acts as a serial input for loading PAE and
PAF offsets into the programmable registers. The serial input function can
only be used when the serial loading method has been selected during
Master Reset. Serial programming using the FWFT/SI pin functions the
same way in both IDT Standard and FWFT modes.
WRITE CLOCK (WCLK)
A write cycle is initiated on the rising edge of the WCLK input. Data setup
and hold times must be met with respect to the LOW-to-HIGH transition of
the WCLK. It is permissible to stop the WCLK. Note that while WCLK is idle,
the FF/IR, PAF and HF flags will not be updated. (Note that WCLK is only
capable of updating HF flag to LOW.) The Write and Read Clocks can
either be independent or coincident.
13
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
WRITE ENABLE (WEN)
When the WEN input is LOW, data may be loaded into the FIFO RAM
array on the rising edge of every WCLK cycle if the device is not full. Data
is stored in the RAM array sequentially and independently of any ongoing
read operation.
When WEN is HIGH, no new data is written in the RAM array on each
WCLK cycle.
To prevent data overflow in the IDT Standard mode, FF will go LOW,
inhibiting further write operations. Upon the completion of a valid read
cycle, FF will go HIGH allowing a write to occur. The FF is updated by two
WCLK cycles + tSKEW after the RCLK cycle.
To prevent data overflow in the FWFT mode, IR will go HIGH, inhibiting
further write operations. Upon the completion of a valid read cycle, IR will
go LOW allowing a write to occur. The IR flag is updated by two WCLK
cycles + tSKEW after the valid RCLK cycle.
WEN is ignored when the FIFO is full in either FWFT or IDT Standard
mode.
READ CLOCK (RCLK)
A read cycle is initiated on the rising edge of the RCLK input. Data can
be read on the outputs, on the rising edge of the RCLK input. It is
permissible to stop the RCLK. Note that while RCLK is idle, the EF/OR,
PAE and HF flags will not be updated. (Note that RCLK is only capable of
updating the HF flag to HIGH.) The Write and Read Clocks can be
independent or coincident.
READ ENABLE (REN)
When Read Enable is LOW, data is loaded from the RAM array into the
output register on the rising edge of every RCLK cycle if the device is not
empty.
When the REN input is HIGH, the output register holds the previous data
and no new data is loaded into the output register. The data outputs Q0-
Qn maintain the previous data value.
In the IDT Standard mode, every word accessed at Qn, including the first
word written to an empty FIFO, must be requested using REN. When the
last word has been read from the FIFO, the Empty Flag (EF) will go LOW,
inhibiting further read operations. REN is ignored when the FIFO is empty.
Once a write is performed, EF will go HIGH allowing a read to occur. The
EF flag is updated by two RCLK cycles + tSKEW after the valid WCLK cycle.
In the FWFT mode, the first word written to an empty FIFO automatically
goes to the outputs Qn, on the third valid LOW to HIGH transition of RCLK
+ tSKEW after the first write. REN does not need to be asserted LOW. In
order to access all other words, a read must be executed using REN. The
RCLK LOW to HIGH transition after the last word has been read from the
FIFO, Output Ready (OR) will go HIGH with a true read (RCLK with REN
= LOW), inhibiting further read operations. REN is ignored when the FIFO
is empty.
SERIAL ENABLE (SEN)
The SEN input is an enable used only for serial programming of the
offset registers. The serial programming method must be selected during
Master Reset. SEN is always used in conjunction with LD. When these
lines are both LOW, data at the SI input can be loaded into the program
register one bit for each LOW-to-HIGH transition of WCLK. (See Figure 4.)
When SEN is HIGH, the programmable registers retains the previous
settings and no offsets are loaded. SEN functions the same way in both
IDT Standard and FWFT modes.
OUTPUT ENABLE (OE)
When Output Enable is enabled (LOW), the parallel output buffers
receive data from the output register. When OE is HIGH, the output data
bus (Qn) goes into a high impedance state.
LOAD (LD)
This is a dual purpose pin. During Master Reset, the state of the LD input
determines one of two default offset values (127 or 1,023) for the PAE and
PAF flags, along with the method by which these offset registers can be
programmed, parallel or serial. After Master Reset, LD enables write
operations to and read operations from the offset registers. Only the offset
loading method currently selected can be used to write to the registers.
Offset registers can be read only in parallel. A LOW on LD during Master
Reset selects a default PAE offset value of 07FH (a threshold 127 words
from the empty boundary), a default PAF offset value of 07FH (a threshold
127 words from the full boundary), and parallel loading of other offset
values. A HIGH on LD during Master Reset selects a default PAE offset
value of 3FFH (a threshold 1,023 words from the empty boundary), a
default PAF offset value of 3FFH (a threshold 1,023 words from the full
boundary), and serial loading of other offset values.
After Master Reset, the LD pin is used to activate the programming
process of the flag offset values PAE and PAF. Pulling LD LOW will begin
a serial loading or parallel load or read of these offset values. See Figure
4, Programmable Flag Offset Programming Sequence.
OUTPUTS:
FULL FLAG (FF/IR)
This is a dual purpose pin. In IDT Standard mode, the Full Flag (FF)
function is selected. When the FIFO is full, FF will go LOW, inhibiting further
write operations. When FF is HIGH, the FIFO is not full. If no reads are
performed after a reset (either MRS or PRS), FF will go LOW after D writes
to the FIFO (D = 16,384 for the IDT72261LA and 32,768 for the
IDT72271LA). See Figure 7, Write Cycle and Full Flag Timing (IDT
Standard Mode), for the relevant timing information.
In FWFT mode, the Input Ready (IR) function is selected. IR goes LOW
when memory space is available for writing in data. When there is no
longer any free space left, IR goes HIGH, inhibiting further write opera-
tions. If no reads are performed after a reset (either MRS or PRS), IR will
go HIGH after D writes to the FIFO (D = 16,385 for the IDT72261LA and
32,769 for the IDT72271LA) See Figure 9, Write Timing (FWFT Mode), for
the relevant timing information.
The IR status not only measures the contents of the FIFO memory, but
also counts the presence of a word in the output register. Thus, in FWFT
mode, the total number of writes necessary to deassert IR is one greater
than needed to assert FF in IDT Standard mode.
FF/IR is synchronous and updated on the rising edge of WCLK. FF/IR
are double register-buffered outputs.
EMPTY FLAG (EF/OR)
This is a dual purpose pin. In the IDT Standard mode, the Empty Flag
(EF) function is selected. When the FIFO is empty, EF will go LOW,
inhibiting further read operations. When EF is HIGH, the FIFO is not
empty. See Figure 8, Read Cycle, Empty Flag and First Word Latency
Timing (IDT Standard Mode), for the relevant timing information.
In FWFT mode, the Output Ready (OR) function is selected. OR goes
LOW at the same time that the first word written to an empty FIFO appears
14
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
valid on the outputs. OR stays LOW after the RCLK LOW to HIGH transition
that shifts the last word from the FIFO memory to the outputs. OR goes
HIGH only with a true read (RCLK with REN = LOW). The previous data
stays at the outputs, indicating the last word was read. Further data reads
are inhibited until OR goes LOW again. See Figure 10, Read Timing (FWFT
Mode), for the relevant timing information.
EF/OR is synchronous and updated on the rising edge of RCLK.
In IDT Standard mode, EF is a double register-buffered output. In FWFT
mode, OR is a triple register-buffered output.
PROGRAMMABLE ALMOST-FULL FLAG (PAF)
The Programmable Almost-Full flag (PAF) will go LOW when the FIFO
reaches the almost-full condition. In IDT Standard mode, if no reads are
performed after reset (MRS), PAF will go LOW after (D - m) words are
written to the FIFO. The PAF will go LOW after (16,384-m) writes for the
IDT72261LA and (32,768-m) writes for the IDT72271LA. The offset “m” is
the full offset value. The default setting for this value is stated in the footnote
of Table 1.
In FWFT mode, the PAF will go LOW after (16,385-m) writes for the
IDT72261LA and (32,769-m) writes for the IDT72271LA, where m is the full
offset value. The default setting for this value is stated in the footnote of
Table 2.
See Figure 16, Programmable Almost-Full Flag Timing (IDT Standard
and FWFT Mode), for the relevant timing information.
PAF is synchronous and updated on the rising edge of WCLK.
PROGRAMMABLE ALMOST-EMPTY FLAG (PAE)
The Programmable Almost-Empty flag (PAE) will go LOW when the FIFO
reaches the almost-empty condition. In IDT Standard mode, PAE will go
LOW when there are n words or less in the FIFO. The offset “n” is the empty
offset value. The default setting for this value is stated in the footnote of
Table 1.
In FWFT mode, the PAE will go LOW when there are n+1 words or less
in the FIFO. The default setting for this value is stated in the footnote of Table
2. See Figure 17, Programmable Almost-Empty Flag Timing (IDT Standard
and FWFT Mode), for the relevant timing information.
PAE is synchronous and updated on the rising edge of RCLK.
HALF-FULL FLAG (HF)
This output indicates a half-full FIFO. The rising WCLK edge that fills the
FIFO beyond half-full sets HF LOW. The flag remains LOW until the
difference between the write and read pointers becomes less than or equal
to half of the total depth of the device; the rising RCLK edge that accom-
plishes this condition sets HF HIGH.
In IDT Standard mode, if no reads are performed after reset (MRS or
PRS), HF will go LOW after (D/2 + 1) writes to the FIFO, where D = 16,384
for the IDT72261LA and 32,768 for the IDT72271LA.
In FWFT mode, if no reads are performed after reset (MRS or PRS), HF
will go LOW after (D-1/2 + 2) writes to the FIFO, where D = 16,385 for the
IDT72261LA and 32,769 for the IDT72271LA.
See Figure 18, Half-Full Flag Timing (IDT Standard and FWFT Modes),
for the relevant timing information. Because HF is updated by both RCLK
and WCLK, it is considered asynchronous.
DATA OUTPUTS (Q0-Q8)
(Q0 - Q8) are data outputs for 9-bit wide data.
15
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 5. Master Reset Timing
MRS
REN
FWFT/SI
4671 drw 08
tFWFT
WEN
LD
RT
SEN
tRSF
tRSF
OE = HIGH
OE = LOW
PAE
PAF, HF
Q0 - Qn
tRSF
EF/OR
FF/IR
tRSF
tRSF If FWFT = HIGH, OR = HIGH
If FWFT = LOW, EF = LOW
If FWFT = LOW, FF = HIGH
If FWFT = HIGH, IR = LOW
tRS
tRSS
tRSS
tRSS
tRSS
tRSS
tRSR
tRSR
tRSR
tRSR
16
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 6. Partial Reset Timing
tRS
PRS
tRSR
REN
tRSS
4671 drw 09
tRSR
WEN
tRSS
RT
SEN
tRSS
tRSF
tRSF
OE = HIGH
OE = LOW
PAE
PAF, HF
Q0 - Qn
tRSF
EF/OR
FF/IR
tRSF
tRSF If FWFT = HIGH, OR = HIGH
If FWFT = LOW, EF = LOW
If FWFT = LOW, FF = HIGH
If FWFT = HIGH, IR = LOW
tRSS
17
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 8. Read Cycle, Empty Flag and First Data Word Latency Timing (IDT Standard Mode)
NOTES:
1. tSKEW3 is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that EF will go HIGH (after one RCLK cycle plus tREF). If the time between the rising
edge of WCLK and the rising edge of RCLK is less than tSKEW3, then EF deassertion may be delayed one extra RCLK cycle.
2. LD = HIGH.
3. First word latency: 60ns + tREF + 1*TRCLK.
NOTES:
1. tSKEW1 is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that FF will go high (after one WCLK cycle pus tWFF). If the time between the
rising edge of the RCLK and the rising edge of the WCLK is less than tSKEW1, then the FF deassertion may be delayed one extra WCLK cycle.
2. LD = HIGH, OE = LOW, EF = HIGH
Figure 7. Write Cycle and Full Flag Timing (IDT Standard Mode)
D
0
- D
n
WEN
RCLK
REN
t
ENH
t
ENH
Q
0
- Q
n
DATA READ NEXT DATA READDATA IN OUTPUT REGISTER
t
SKEW1
(1)
4671 drw 10
WCLK
NO WRITE
1212
t
DS
NO WRITE
t
WFF
t
WFF
t
WFF
t
A
t
ENS
t
ENS
t
SKEW1
(1)
t
DS
t
A
DX
t
DH
DX+1
t
WFF
t
DH
t
CLKL
t
CLK
t
CLKH
RCLK
REN
4671 drw 11
EF
t
CLKH
t
CLKL
t
ENH
t
REF
t
A
t
OLZ
t
OE
Q
0
- Q
n
OE
WCLK
(1)
t
SKEW3
WEN
D
0
- D
n
t
ENS
t
ENS
t
ENH
t
DS
t
DHS
D
0
12
t
OLZ
LAST WORD D
0
D
1
D
1
t
ENS
t
ENH
t
DS
t
DH
t
OHZ
LAST WORD
t
REF
t
ENH
t
ENS
t
A
t
A
t
ENS
t
ENH
t
CLK
NO OPERATION
NO OPERATION
t
REF
18
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 9. Write Timing (First Word Fall Through Mode)
W
1
W
2
W
4
W
[n +2]
W
[D-m-1]
W
[D-m-2]
W
[D-1]
W
D
W
[n+3]
W
[n+4]
W
[D-m]
W
[D-m+1]
WCLK
WEN
D
0
- D
8
RCLK
t
DH
t
DS
t
ENS
t
SKEW3
(1)
REN
Q
0
- Q
8
PAF
HF
PAE
IR
t
DS
t
DS
t
DS
t
SKEW2
t
A
t
REF
OR
t
HF
t
PAF
t
WFF
W
[D-m+2]
W
1
t
ENH
4671 drw 12
DATA IN OUTPUT REGISTER
(2)
W
3
123
1
D-1
2+1][
W
D-1
+2][
W2
D-1
+3][
W2
12
t
PAE
NOTES:
1. tSKEW3 is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that OR will go LOW after two RCLK cycles plus tREF. If the time between the rising edge of WCLK and the rising edge of RCLK
is less than tSKEW3, then OR assertion may be delayed one extra RCLK cycle.
2. tSKEW2 is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that PAE will go HIGH after one RCLK cycle plus tPAE. If the time between the rising edge of WCLK and the rising edge of RCLK
is less than tSKEW2, then the PAE deassertion may be delayed one extra RCLK cycle.
3. LD = HIGH, OE = LOW
4. n = PAE offset, m = PAF offset and D = maximum FIFO depth.
5. D = 16,385 for the IDT72261LA and 32,769 for the IDT72271LA.
6. First word latency: 60ns + tREF + 2*TRCLK.
19
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 10. Read Timing (First Word Fall Through Mode)
NOTES:
1. tSKEW1 is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that IR will go LOW after one WCLK cycle plus tWFF. If the time between the rising edge of RCLK and the rising edge of WCLK
is less than tSKEW1, then the IR assertion may be delayed one extra WCLK cycle.
2. tSKEW2 is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that PAF will go HIGH after one WCLK cycle plus tPAF. If the time between the rising edge of RCLK and the rising edge of WCLK
is less than tSKEW2, then the PAF deassertion may be delayed one extra WCLK cycle.
3. LD = HIGH
4. n = PAE Offset, m = PAF offset and D = maximum FIFO depth.
5. D = 16,385 for the IDT72261LA and 32,769 for the IDT72271LA.
WCLK 12
WEN
D
0
- D
8
RCLK
t
ENS
REN
Q
0
- Q
8
PAF
HF
PAE
IR
OR
W
1
W
1
W
2
W
3
W
m+2
W
[m+3]
t
OHZ
t
SKEW1
t
ENH
t
DS
t
DH
t
OE
t
A
t
A
t
A
t
PAF
t
WFF
t
WFF
t
ENS
OE
t
SKEW2
W
D
4671 drw 13
t
PAE
W
[D-n]
W
[D-n-1]
t
A
t
A
t
HF
t
REF
W
[D-1]
W
D
t
A
W
[D-n+1]
W
[m+4]
W
[D-n+2]
(1) (2)
t
ENS
D-1
+ 1][
W
2
D-1
+ 2][
W
2
1
20
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
NOTES:
1. Retransmit setup is complete after EF returns HIGH, only then can a read operation begin.
2. OE = LOW.
3. W1 = first word written to the FIFO after Master Reset, W2 = second word written to the FIFO after Master Reset.
4. No more than D - 2 may be written to the FIFO between Reset (Master or Partial) and Retransmit setup. Therefore, FF will be HIGH throughout the Retransmit setup procedure.
D = 16,384 for the IDT72261LA and 32,768 for the IDT72271LA.
5. EF goes HIGH at 60 ns + 1 RCLK cycle + tREF.
Figure 11. Retransmit Timing (IDT Standard Mode)
t
REF
t
ENH
4671 drw14
t
A
t
ENS
W
x
WCLK
RCLK
REN
RT
EF
PAF
HF
PAE
Q
0
- Q
n
t
SKEW4
12
1
W
1
t
HF
t
PAE
t
REF
W
x+1
2
W
2
t
ENH
WEN
t
ENS
t
ENS
t
ENH
(3)
t
A
t
A
(3)
(5)
t
RTS
t
RTS
t
PAF
21
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
NOTES:
1. Retransmit setup is complete after OR returns LOW.
2. No more than D - 2 words may be written to the FIFO between Reset (Master or Partial) and Retransmit setup. Therefore, IR will be LOW throughout the Retransmit setup
procedure. D = 16,385 for the IDT72261LA and 32,769 for the IDT72271LA.
3. OE = LOW
4. W1, W2, W3 = first, second and third words written to the FIFO after Master Reset.
5. OR goes LOW at 60 ns + 2 RCLK cycles + tREF.
Figure 12. Retransmit Timing (FWFT Mode)
Figure 13. Serial Loading of Programmable Flag Registers (IDT Standard and FWFT Modes)
WCLK
SEN
SI
4671 drw 16
tENH
t
ENS
t
LDS
LD
t
DS
BIT 0
EMPTY OFFSET
BIT X BIT 0
FULL OFFSET
(1)
t
ENH
BIT X (1)
t
LDH
t
LDH
t
LDH
t
DH
t
REF
t
ENH
4671 drw15
t
ENS
W
x
WCLK
RCLK
REN
RT
OR
PAF
HF
PAE
Q
0
- Q
n
t
SKEW4
12
1
t
HF
t
PAE
t
REF
W
x+1
2
W
2
t
ENH
WEN
t
ENS
W
1
t
ENH
(4)
(5)
34
t
ENH
W
3
t
RTS
t
RTS
t
PAF
t
A
t
A
NOTE:
1. X = 13 for the IDT72261LA and X = 14 for the IDT72271LA.
22
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
WCLK
LD
WEN
D
0
- D
7
t
LDS
t
ENS
PAE OFFSET
(LSB)
t
DS
t
DH
t
ENH
PAF OFFSET
(LSB)
PAF OFFSET
(MSB)
4671 drw 17
t
LDH
t
DH
t
CLKL
t
LDH
PAE OFFSET
(MSB)
t
CLKH
t
CLK
t
ENH
NOTES:
1. m = PAF offset .
2. D = maximum FIFO depth.
In IDT Standard mode: D = 16,384 for the IDT72261LA and 32,768 for the IDT72271LA.
In FWFT mode: D = 16,385 for the IDT72261LA and 32,769 for the IDT72271LA.
3. tSKEW2 is the minimum time between a rising RCLK edge and a rising WCLK edge to guarantee that PAF will go HIGH (after one WCLK cycle plus tPAF). If the time between the
rising edge of RCLK and the rising edge of WCLK is less than tSKEW2, then the PAF deassertion time may be delayed one extra WCLK cycle.
4. PAF is asserted and updated on the rising edge of WCLK only.
Figure 16. Programmable Almost-Full Flag Timing (IDT Standard and FWFT Modes)
Figure 14. Parallel Loading of Programmable Flag Registers (IDT Standard and FWFT Modes)
RCLK
LD
REN
Q0 - Q7
tLDH
tLDS
tENS
DATA IN OUTPUT
REGISTER
tENH
4671 drw 18
t
CLK
tAtA
PAF OFFSET
(MSB)
PAF OFFSET
(LSB)
PAE OFFSET
(MSB)
PAE OFFSET
(LSB)
tCLKH tCLKL
tLDH
tENH
Figure 15. Parallel Read of Programmable Flag Registers (IDT Standard and FWFT Modes)
WCLK
t
ENH
t
CLKH
t
CLKL
WEN
PAF
RCLK
(3)
REN
4671 drw 19
t
ENS
t
ENH
t
ENS
D - (m+1) words in FIFO
(2)
t
SKEW2
1212
D-(m+1) words
in FIFO
(2)
t
PAF
D - m words in FIFO
(2)
t
PAF
NOTE:
1. OE = LOW
23
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
NOTES:
1. n = PAE offset.
2. For IDT Standard mode
3. For FWFT mode.
4. tSKEW2 is the minimum time between a rising WCLK edge and a rising RCLK edge to guarantee that PAE will go HIGH (after one RCLK cycle plus tPAE). If the time between
the rising edge of WCLK and the rising edge of RCLK is less than tSKEW2, then the PAE deassertion may be delayed one extra RCLK cycle.
5. PAE is asserted and updated on the rising edge of WCLK only.
Figure 18. Half-Full Flag Timing (IDT Standard and FWFT Modes)
WCLK
t
ENH
t
CLKH
t
CLKL
WEN
PAE
RCLK
t
ENS
t
PAE
t
SKEW2
t
PAE
12 12
(4)
REN 4671 drw 20
t
ENS
t
ENH
n+1 words in FIFO
(2),
n+2 words in FIFO
(3)
n words in FIFO
(2),
n+1 words in FIFO
(3)
n words in FIFO
(2),
n+1 words in FIFO
(3)
WCLK
t
ENS
t
ENH
WEN
HF
t
ENS
RCLK
REN
4671 drw 21
D/2 words in FIFO(1),
[
+ 1
]
words in FIFO(2)
D-1
2
D/2 + 1 words in FIFO(1),
[
+ 2
]
words in FIFO(2)
D-1
2
D/2 words in FIFO(1),
[
+ 1
]
words in FIFO(2)
D-1
2
t
CLKH
t
CLKL
t
HF
t
HF
Figure 17. Programmable Almost-Empty Flag Timing (IDT Standard and FWFT Modes)
NOTES:
1. For IDT Standard mode: D = maximum FIFO depth. D = 16,384 for the IDT72261LA and 32,768 for the IDT72271LA.
2. For FWFT mode: D = maximum FIFO depth. D = 16,385 for the IDT72261LA and 32,769 for the IDT72271LA.
24
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
NOTES:
1. Use an AND gate in IDT Standard mode, an OR gate in FWFT mode.
2. Do not connect any output control signals directly together.
3. FIFO #1 and FIFO #2 must be the same depth, but may be different word widths.
OPTIONAL CONFIGURATIONS
WIDTH EXPANSION CONFIGURATION
Word width may be increased simply by connecting together the control
signals of multiple devices. Status flags can be detected from any one device.
The exceptions are the EF and FF functions in IDT Standard mode and the
IR and OR functions in FWFT mode. Because of variations in skew between
RCLK and WCLK, it is possible for EF/FF deassertion and IR/OR assertion
to vary by one cycle between FIFOs. In IDT Standard mode, such problems
Figure 19. Block Diagram of 16,384 x 18 and 32,768 x 18 Width Expansion
WRITE CLOCK (WCLK)
m + n m n
MASTER RESET (MRS)
READ CLOCK (RCLK)
DATA OUT
nm + n
WRITE ENABLE (WEN)
FULL FLAG/INPUT READY (FF/IR)
PROGRAMMABLE (PAF)
PROGRAMMABLE (PAE)
EMPTY FLAG/OUTPUT READY (EF/OR) #2
OUTPUT ENABLE (OE)
READ ENABLE (REN)
m
LOAD (LD)IDT
72261LA
72271LA
EMPTY FLAG/OUTPUT READY (EF/OR) #1
PARTIAL RESET (PRS)
IDT
72261LA
72271LA
4671 drw 22
FULL FLAG/INPUT READY (FF/IR) #2
HALF-FULL FLAG (HF)
FIRST WORD FALL THROUGH/
SERIAL INPUT (FWFT/SI)
RETRANSMIT (RT)
#1
FIFO
#2
GATE
(1)
GATE
(1)
D
0
- Dm
DATA IN
Dm
+1
- Dn
Q
0
- Qm
Qm
+1
- Qn
FIFO
#1
can be avoided by creating composite flags, that is, ANDing EF of every FIFO,
and separately ANDing FF of every FIFO. In FWFT mode, composite flags
can be created by ORing OR of every FIFO, and separately ORing IR of every
FIFO.
Figure 21 demonstrates a width expansion using two IDT72261LA/
72271LA devices. D0 - D8 from each device form a 18-bit wide input bus and
Q0-Q8 from each device form a 18-bit wide output bus. Any word width can
be attained by adding additional IDT72261LA/72271LA devices.
25
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
IDT72261LA/72271LA SuperSync FIFO™
16,384 x 9 and 32,768 x 9
JANUARY 7, 2009
Figure 20. Block Diagram of 32,768 x 9 and 65,536 x 9 Depth Expansion
DEPTH EXPANSION CONFIGURATION (FWFT MODE ONLY)
The IDT72261LA can easily be adapted to applications requiring depths
greater than 16,384 and 32,768 for the IDT72271LA with a 9-bit bus width.
In FWFT mode, the FIFOs can be connected in series (the data outputs of one
FIFO connected to the data inputs of the next) with no external logic necessary.
The resulting configuration provides a total depth equivalent to the sum of the
depths associated with each single FIFO. Figure 22 shows a depth expansion
using two IDT72261LA/72271LA devices.
Care should be taken to select FWFT mode during Master Reset for all
FIFOs in the depth expansion configuration. The first word written to an empty
configuration will pass from one FIFO to the next ("ripple down") until it finally
appears at the outputs of the last FIFO in the chain–no read operation is
necessary but the RCLK of each FIFO must be free-running. Each time the
data word appears at the outputs of one FIFO, that device's OR line goes LOW,
enabling a write to the next FIFO in line.
For an empty expansion configuration, the amount of time it takes for OR of
the last FIFO in the chain to go LOW (i.e. valid data to appear on the last FIFO's
outputs) after a word has been written to the first FIFO is the sum of the delays
for each individual FIFO:
(N – 1)*(4*transfer clock) + 3*TRCLK
where N is the number of FIFOs in the expansion and TRCLK is the RCLK
period. Note that extra cycles should be added for the possibility that the tSKEW3
Dn
INPUT READY
WRITE ENABLE
WRITE CLOCK
WEN
WCLK
IR
DATA IN
RCLK READ CLOCK
RCLK
REN
OE OUTPUT ENABLE
OUTPUT READY
Qn
Dn
IR
GND
WEN
WCLK
OR
REN
OE
Qn
READ ENABLE
OR
DATA OUT
IDT
72261LA
72271LA
TRANSFER CLOCK
4671 drw 23
n
n n
FWFT/SI FWFT/SI
FWFT/SI
IDT
72261LA
72271LA
specification is not met between WCLK and transfer clock, or RCLK and transfer
clock, for the OR flag.
The "ripple down" delay is only noticeable for the first word written to an
empty depth expansion configuration. There will be no delay evident for
subsequent words written to the configuration.
The first free location created by reading from a full depth expansion
configuration will "bubble up" from the last FIFO to the previous one until it finally
moves into the first FIFO of the chain. Each time a free location is created in
one FIFO of the chain, that FIFO's IR line goes LOW, enabling the preceding
FIFO to write a word to fill it.
For a full expansion configuration, the amount of time it takes for IR of the first
FIFO in the chain to go LOW after a word has been read from the last FIFO
is the sum of the delays for each individual FIFO:
(N – 1)*(3*transfer clock) + 2 TWCLK
where N is the number of FIFOs in the expansion and TWCLK is the WCLK
period. Note that extra cycles should be added for the possibility that the
tSKEW1 specification is not met between RCLK and transfer clock, or WCLK
and transfer clock, for the IR flag.
The Transfer Clock line should be tied to either WCLK or RCLK,
whichever is faster. Both these actions result in data moving, as quickly
as possible, to the end of the chain and free locations to the beginning of
the chain.
26
CORPORATE HEADQUARTERS for SALES: for Tech Support:
6024 Silver Creek Valley Road 800-345-7015 or 408-284-8200 408-360-1753
San Jose, CA 95138 fax: 408-284-2775 email: FIFOhelp@idt.com
www.idt.com
ORDERING INFORMATION
Thin Plastic Quad Flatpack (TQFP, PN64-1)
Slim Thin Quad Flatpack (STQFP, PP64-1)
Commercial (0°C to +70°C)
Industrial (-40°C to +85°C)
Low Power
16,384 x 9 — SuperSync FIFO
32,768 x 9 — SuperSync FIFO
4671 drw24
Clock Cycle Time (t
CLK
)
Speed in Nanoseconds
Com'l & Ind'l
Com‘l & Ind’l
XXXXX
Device Type
X
Power
XX
Speed
X
Package
X
Process /
Temperature
Range
BLANK
I
(1)
72261
72271
Commercial Only
LA
G
PF
TF
10
15
20
X
Green
NOTES:
1. Industrial temperature range product for 15ns and 20ns speed grade are available as a standard device.
2. Green parts available. For specific speeds and packages contact your sales office.
DATASHEET DOCUMENT HISTORY
04/26/2001 pgs. 1, 5, 6 and 26.
10/17/2005 pgs. 1, 6, 20, 21 and 26. PCN#F0509-01.
01/07/2009 pg. 26.
27
©2009 Integrated Device Technology, Inc. All rights reserved. Product specifications subject to change without notice
3.3 VOLT CMOS SuperSync FIFO
16,384 x 9
32,768 x9
IDT72261LA
IDT72271LA
IDT, IDT logo are registered trademarks of Integrated Device Technology, Inc.The SuperSync FIFO is a trademark of Integrated Device Technology, Inc.
COMMERCIAL AND INDUSTRIAL TEMPERATURE RANGES
ADDENDUM
DIFFERENCES BETWEEN THE IDT72261LA/72271LA AND IDT72261L/72271L
IDT has improved the performance of the IDT72261/72271 SuperSync™ FIFOs. The new versions are designated by the “LA” mark. The LA part
is pin-for-pin compatible with the original “L” version. Some difference exist between the two versions. The following table details these differences.
Item NEW PART OLD PART Comments
IDT72261LA IDT72261L
IDT72271LA IDT72271L
Pin #3 DC (Don’t Care) - There is FS (Frequency Select) In the LA part this pin must be tied
no restriction on WCLK and to either VCC or GND and must
RCLK. See note 1. not toggle after reset.
First Word Latency 60ns(2) + tREF + 1 TRCLK(4) tFWL1 = 10*Tf(3) + 2TRCLK(4)(ns) First word latency in the LA part
(IDT Standard Mode) is a fixed value, independent of
the frequency of RCLK or WCLK.
First Word Latency 60ns(2) + tREF + 2 TRCLK(4) tFWL2 = 10*Tf(3) + 3TRCLK(4)(ns) First word latency in the LA part
(FWFT Mode) is a fixed value, independent of
the frequency of RCLK or WCLK.
Retransmit Latency 60ns(2) + tREF + 1 TRCLK(4) tRTF1 = 14*Tf(3) + 3TRCLK(4)(ns) Retransmit latency in the LA part
(IDT Standard Mode) is a fixed value, independent of
the frequency of RCLK or WCLK.
Retransmit Latency 60ns(2) + tREF + 2 TRCLK(4) tRTF2 = 14*Tf(3) + 4TRCLK(4)(ns) Retransmit latency in the LA part
(FWFT Mode) is a fixed value, independent of
the frequency of RCLK or WCLK.
ICC1 75mA 150mA Active supply current
ICC2 20mA 15mA Standby current
Typical ICC1(5) 15 + 1.85*fS + 0.02*CL*fS(mA) Not Given Typical ICC1 Current calculation
NOTES:
1. WCLK and RCLK can vary independently and can be stopped. There is no restriction on operating WCLK and RCLK.
2. This is tSKEW3.
3. Tf is the period of the ‘selected clock’.
4. TRCLK is the cycle period of the read clock.
5. Typical ICC1 is based on VCC = 5V, tA = 25C, fS = WCLK frequency = RCLK frequency (in MHz using TTL levels), data switching at fS/2, CL = Capacitive Load (in pF).