FEATURES
Surge overload rating - 125 amperes peak
Ideal for printed circuit board
Plastic material has underwriters laboratory
flammability classification 94V-0
Mounting position: Any
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SYMBOL GBL005 GBL01 GBL02 GBL04 GBL06 GBL08 GBL10 UNIT
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS Bridge Input Voltage VRMS 30 70 140 280 420 560 700 V
Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 V
Maximum Average Forward Rectified
Output Current @ TA=50 (Note1)
Peak Forward Surage Current
8.3ms Single Half Sine-Wave
Super Imposed on Rated Load
Maximum Forward Voltage Drop
Per Bridge Element at 4.0A Peak
Maximum Reverse Current at Rated
DC Blocking Voltage
Maximum Reverse Current at Rated
DC Blocking Voltage @ TA =150
Operating Temperature Range TJ
Storage Temperature Range TSTG
Single phase, half wave ,60Hz, resistive or inductive load.
Rating at 25 ambient temperature unless otherwise specified.
GLASS PASSIVATED
BRIDGE RECTIFIERS
Dimensions in inches and (milimeters)
REVERSE VOLTAGE - 50 to 1000Volts
FORWARD CURRENT - 4.0 Amperes
For capacitive load, derate current by 20%
4.0
10.0
IR1.0
uA
mA
Note:1.Mounting conditions,0.5lead length maximum.
A
125
-55 to +150
IFSM
~ 295 ~
GBL005 thru GBL10
A
IR
VFV1.1
I(AV)
-55 to +150
2GBJ
.015(0.38)
.020(0.51)
.035(0.9)
.043(1.1)
.44(11.2)
.42(10.7)
.50(12.7)
.56(14.2)
.035(0.90)
.045(1.14)
.190
.210
(4.8)
(5.3)(5.3)
(4.8)
.210
.190
.77(19.6)
.81(20.6)
.106(2.7)
.091(2.3)
.055(1.4)
.047(1.2)
.142(3.6)
.133(3.4)
.190
.210
(4.8)
(5.3)
.125(3.17)
*45°
Chamfer
RATING AND CHARACTERISTIC CURVES
~ 296 ~
GBL005 thru GBL10
0.4 0.6 0.8 1.0 1.2 1.4
0.1
1.0
10
100
200
00.2
TJ=25
INSTANTANEOUS FORWARD CURRENT
AMPERES
FIG.2-TYPICAL FORWARD
CHARACTERISTICS
INSTANTANEOUS FORWARD VOLTAGE. VOLTS
TJ=25
PULSE WIDTH 300us
PEAK FORWARD SURGE CURRENT
AMPERES
FIG.1-MAXIMUM NON-REPETITIVE SURGE CURRENT
NUMBER OF CYCLES AT 60HZ
1 10 100
180
160
120
80
40
0
TJ=25
SINGLE HALF-SINE-WAVE
(JEDEC METHOD)
AMBIENT TEMPERATURE
AVERAGE FORWARD OUTPUT CURRENT
AMPERES
FIG.2-FORWARD DERATING
CURRENT
50 100
0150
5.0
4.0
3.0
2.0
0
1.0
CASE
AMBIENT
RESISTIVE OR INDUCTIVE LOADS
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
PERCENT OF RATED PEAK REVERSE VOLTAGE
INSTANTANEOUS REVERSE CUNRRENT.
MICROAMPERES
0.01
0.1
1.0
10
020 40 60 80 100 120 140
TJ=100
TJ=25