Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
461
800-262-IDEC (4332) USA & Canada
ø16mm XA E-Stops
Switches & Pilot Devices
16mm XA E-Stops
Key features:
• Twobuttonsizes:ø29andø40mm
• Lead-free,RoHScompliant,(EUdirective2002/95/EC)
• Depthbehindthepanel:
Standard-only27.9mmfor1to4contacts
Unibody-only23.9mmfor1NCor2NC
• IDEC’soriginal“Safebreakaction”ensuresthattheNCcontactsopen
whenthecontactblockisdetachedfromtheoperator.
• Push-to-lock,PullorTurn-to-resetoperator
• Directopeningactionmechanism(IEC60947-5-5,5.2,IEC60947-5-1,
AnnexK)
• Safetylockmechanism(IEC60947-5-5,6.2)
• Degreeofprotection:
Standard-IP65(IEC60529)
Unibody-IP65andIP40(IEC60529)
• UL,c-ULrecognized.ENcompliant
• ULNISD2categoryemergencystopbutton(File#E305148)
ULFileNo.E68691 CCCNo.2005010305150899
Specifications
Model Standard Unibody
Applicable Standards IEC60947-5-1,EN60947-5-1,IEC60947-5-5,EN60947-5-5,UL508,
UL991,CSAC22.2No.14
UL508,CSAC22.2No.14,IEC60947-5-1,EN60947-5-1
IEC60947-5-5Note,EN60947-5-5Note,JISC8201-5-1
Operating Temperature Non-illuminated:–25to+60°C(nofreezing),
Illuminated:–25to+55°C(nofreezing) −25to+60°C(nofreezing)
Operating Humidity 45to85%RH(nocondensation)
Storage Temperature –45to+80°C
Operating Force Push-to-lock:10.5NPull-to-reset:10NTurn-to-reset:0.16N·m
Minimum Force Required for
Direct Opening Action 60N 40N
Min Operator Stroke Required
for Direct Opening Action 4mm
Maximum Operator Stroke 4.5mm
Contact Resistance 50mΩmaximum(initialvalue)
Contact Material Goldplatedsilver
Insulation Resistance 100MΩminimum(500VDCmegger)
Impulse Withstand Voltage 2.5kV
Pollution Degree 3(insideLEDunit:2) 3
Operation Frequency 900operations/hour
Shock Resistance Operatingextremes:150m/s2,Damagelimits:1000m/s2
Vibration Resistance Operatingextremes:10to500Hz,amplitude0.35mmacceleration50m/s2,Damagelimits:10to500Hz,amplitude0.35mmacceleration50m/s2
Mechanical Life 250,000operationsminimum
Electrical Life 100,000operationsminimum,(250,000operationsminimum@24VAC/DC,100mA)
Degree of Protection IP65(IEC60529) IP65,IP40(IEC60529)
Terminal Style Solderterminal,PCboardterminal Solder/tab#110terminal
Recommended Tightening
Torque for Locking Ring 0.88N·m
Wire Size 16AWGmax
Soldering Conditions 310to350°C,3secondsmaximum
Weight ø29mm:23g
ø40mm:28g
ø29mmmushroom:14g
ø40mmmushroom:17g
Note:Exceptforstopswitches(operatorcolor:yellowandgray)
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø16mm XA E-Stops Switches & Pilot Devices
462  www.IDEC.com
Part Numbers
Non-Illuminated XA E-Stop
Style Termination Monitor Contacts Main Contacts Part Number
29mm
Mushroom PCBTerminal
1NO 1NC XA1E-BV311V-R
2NC XA1E-BV302V-R
1NO 3NC XA1E-BV313V-R
4NC XA1E-BV304V-R
SolderTerminal
1NO 1NC XA1E-BV311-R
2NC XA1E-BV302-R
1NO 3NC XA1E-BV313-R
4NC XA1E-BV304-R
40mm
Mushroom PCBTerminal
1NO 1NC XA1E-BV411V-R
2NC XA1E-BV402V-R
1NO 3NC XA1E-BV413V-R
4NC XA1E-BV404V-R
SolderTerminal
1NO 1NC XA1E-BV411-R
2NC XA1E-BV402-R
1NO 3NC XA1E-BV413-R
4NC XA1E-BV404-R
Illuminated XA E-Stop
Style Termination Monitor Contacts Main Contacts Part Number
29mm
Mushroom PCBTerminal
1NO 1NC XA1E-LV311Q4V-R
2NC XA1E-LV302Q4V-R
1NO 3NC XA1E-LV313Q4V-R
4NC XA1E-LV304Q4V-R
SolderTerminal
1NO 1NC XA1E-LV311Q4-R
2NC XA1E-LV302Q4-R
1NO 3NC XA1E-LV313Q4-R
4NC XA1E-LV304Q4-R
40mm
Mushroom PCBTerminal
1NO 1NC XA1E-LV411Q4V-R
2NC XA1E-LV402Q4V-R
1NO 3NC XA1E-LV413Q4V-R
4NC XA1E-LV404Q4V-R
SolderTerminal
1NO 1NC XA1E-LV411Q4-R
2NC XA1E-LV402Q4-R
1NO 3NC XA1E-LV413Q4-R
4NC XA1E-LV404Q4-R
AllilluminatedXAE-Stopscomewithareplaceable24VAC/DCLED.
Part Number Key
XA1E - L V 3 11 Q4 V - R
Illumination
B: Non-Illuminated
L: Illuminated
Mushroom Size
3: ø29mm
4: ø40mm
Contact Configuration
11:1NO-1NC
02:2NC
13:1NO-3NC
04:4NC
Terminal
Blank: soldertab
V:PCB
Voltage Code
Blank: Non-illuminated
Q4:Illuminated24VAC/DC
Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
463
800-262-IDEC (4332) USA & Canada
ø16mm XA E-Stops
Switches & Pilot Devices
Unibody XA E-Stop
Style Contact
Part Number
IP40 (black housing) IP65 (yellow housing)
29mmMushroom
1NC XA1E-BV3U01KT-R XA1E-BV3U01T-R
2NC XA1E-BV3U02KT-R XA1E-BV3U02T-R
40mmMushroom
1NC XA1E-BV4U01KT-R XA1E-BV4U01T-R
2NC XA1E-BV4U02KT-R XA1E-BV4U02T-R
Unibody XA Stop Switch
Style Operator Type Contact j Color Code
Part Number
IP40
(black housing)
IP65
(yellow housing)
29mm
Mushroom
1NC
Y:yellow
N:gray
XA1E-BV3U01KT-j XA1E-BV3U01T-j
2NC XA1E-BV3U02KT-jXA1E-BV3U02T-j
40mm
Mushroom
1NC XA1E-BV4U01KT-jXA1E-BV4U01T-j
2NC XA1E-BV4U02KT-jXA1E-BV4U02T-j
EMO XA E-Stop
Style NC Main Contact NO Monitor Contact Part Number
40mmMushroom
1NC - XA1E-BV401-RH-EMO
2NC - XA1E-BV402-RH-EMO
3NC - XA1E-BV403-RH-EMO
4NC - XA1E-BV404-RH-EMO
1NC 1NO XA1E-BV411-RH-EMO
2NC 1NO XA1E-BV412-RH-EMO
3NC 1NO XA1E-BV413-RH-EMO
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø16mm XA E-Stops Switches & Pilot Devices
464  www.IDEC.com
Contact Ratings
Standard
Rated Insulation Voltage (Ui) 300V(illuminatedpart:60V)
Rated Current (Ith) 5A
Rated Operating Voltage (Ue) 30V 125V 250V
Rated Operating Current
Main
Contacts (NC)
AC50/60Hz ResistiveLoad(AC-12) 3A 3A
InductiveLoad(AC-15) 1.5A 1.5A
DC ResistiveLoad(DC-12) 2A 0.4A 0.2A
InductiveLoad(DC-13) 1A 0.22A 0.1A
Monitor
Contacts (NO)
AC50/60Hz ResistiveLoad(AC-12) 1.2A 0.6A
InductiveLoad(AC-14) 0.6A 0.3A
DC ResistiveLoad(DC-12) 2A 0.4A 0.2A
InductiveLoad(DC-13) 1A 0.22A 0.1A
Unibody
RatedInsulationVoltage(Ui) 250V
ThermalCurrent(Ith) 5A
RatedOperatingVoltage(Ue) 30V 125V 250V
RatedOperating
Current
AC50/60Hz ResistiveLoad(AC-12) 5A 3A
InductiveLoad(AC-15) 3A 1.5A
DC ResistiveLoad(DC-12) 2A 0.4A 0.2A
InductiveLoad(DC-13) 1A 0.22A 0.1A
Minimumapplicableload:5VAC/DC,1mA(referencevalue).
Theratedoperatingcurrentsaremeasuredatresistive/inductiveloadtypesspecied
inIEC60947-5-1.
Illuminated Unit LED Ratings
Operating Voltage Current
24VAC/DC±10% 11mA
Depth Behind the Panel
Depth (mm) Description
27.9(Standard) 1-4contacts,bothilluminatedandnon-illuminated
23.9(Unibody) 1NCor2NC
Mounting Hole Layout
øA
X
Y
Measurements
Model øA X & Y
ø29mm 16.2+0.2 40mmmin
ø40mm 50mmmin
Panel Cutout
0
+0.2
ø16.2
0
+0.2
1.7
0
+0.2
17.9
PC Board Layout - Bottom View
Non-Illuminated
3-ø1.7 holes
8.7
19.8
8.7
19.8
10-ø1.2 holes
6.5
11.2
Illuminated
8.7
19.8
8.7
19.8
10-ø1.2 holes
6.5
11.2
4.5
3-ø1.7 holes
Terminal Arrangements (Bottom View)
4NC 1NO-3NC 2NC 1NO-1NC
Non-Illuminated TOPTOP
12
21
1
34
2
TOP
12
43
1
34
2
2
12
21
1
12
Left RightLeft Right
TOP
12
21
1
34
2
Left Right
Left
Right
Illuminated
TOPTOP
X2
2
LED
43X1
1
12
21
TOP
X2
2
LED
43X1
1
34
21
12
21
1
X1
LED
2
X212
Left Right
TOP
X2
2
LED
43X1
1
34
21
Left RightLeft Right
Left
Right
Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
465
800-262-IDEC (4332) USA & Canada
ø16mm XA E-Stops
Switches & Pilot Devices
Dimensions (mm)
ø29mm Button
25.8
20.6
30.4
ø40mm Button
ø40
ø29
Non-Illuminated
Solder Terminal TypePC Board Terminal Type
3.1
Locking Ring
Rubber Gasket
Mounting Panel Thickness: 0.5 to 3.7
XA9Z-VL2
Terminal Cover
19.8
8.7
2.1
27.2
25.8 20.6
30.4
29.4
30.4
ø29.8
Illuminated
27.2
19.8
8.7
4.5
Mounting Panel Thickness: 0.5 to 3.7
2.1 25.8 20.6
30.4
3.1
29.4
30.4
ø29.8
Locking Ring
Rubber Gasket
XA9Z-VL2
Terminal Cover
PC Board Terminal Solder Terminal
Unibody EMO
20.6
ø40
ø29 mm Mushroom ø40 mm Mushroom
Solder/Tab Terminal #110
(Behind the panel: 23.9)
0
+0.2
ø16.2
0
+0.2
1.7
0
+0.2
17.9
ø29.0
20.6
ø15.8
Panel Thickness 0.8 to 4.5
Mounting Hole
10.2 0.5
15.98.0 Panel Cut-out
ø29.8
21
ø40
0
+0.2
17.9
0
+0.2
1.7
0
+0.2
ø16.2
30.4
19.8
8.7
2.1
27.2
25.8
30.4 20.6
Rubber Gasket
Locking Ring
Terminal Cover
XA9Z-VL2
Panel Thickness 0.5 to 3.7
Solder Terminal Type
Accessories
Description Part Numbers
ReplacementLEDUnit:SolderTerminal XA9Z-LED2R
ReplacementLEDUnit:PCBTerminal XA9Z-LED2VR
TerminalCoverforcontactblock(solderterminalonly) XA9Z-VL2
Accessories: Shroud
Appearance Part Number Applicable Standards
XA9Z-KG1 SEMIS2Compliant
(ApprovedbyTUV)
Accessories: Nameplates
Appearance Legend Part Number Inner Ø Outer Ø Applicable
Mushroom Size
(blank) HAAV-0 16mm 43mm
29mm
“EmergencyStop” HAAV-27 16mm 43mm
(blank) HAAV4-0 16mm 60mm
40mm
“EmergencyStop” HAAV4-27 16mm 60mm
Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
ø16mm XA E-Stops Switches & Pilot Devices
466  www.IDEC.com
Operating Instructions
Removing the Contact Block
Firstunlocktheoperatorbutton.Whilepushingupthewhitebayonetring,using
asmallscrewdriver(width:2.5to3mm)ifnecessary,turnthecontactblock
counterclockwiseandpullout. Do not exert excessive force when using a
screwdriver, otherwise the bayonet ring may be damaged.
kTurncounterclockwise
jPush
BayonetRing
Notes for Removing the Contact Block
1.Whenthecontactblockisremoved,themonitorcontact(NOcontact)is
closed.
2.Whileremovingthecontactblock,donotexertexcessiveforce,otherwisethe
switchmaybedamaged.
Panel Mounting
Removethelockingringfromtheoperatorandcheckthattherubbergasketisin
place.Inserttheoperatorfrompanelfrontintothepanelhole.Facethesidewith
theanti-rotationtabontheoperatorupward,andtightenthelockingring.
OperatorUnit
Anti-rotationTab
RubberGasket
LockingRing
Notes for Panel Mounting
TomountXAemergencystopswitchesontoapanel,tightenthelockingringto
atighteningtorqueof0.88N·mmaximumusingringwrenchMT-001.Donotuse
pliers.Donotexertexcessiveforce,otherwisethelockingringmaybedamaged.
Installing the Contact Block
Firstturnthebayonetringtotheunlockedposition.
BayonetRing
Unlocked Locked
AlignthesmallpmarkingontheedgeoftheoperatorbasewiththeTOPmark-
ingonthecontactblock.Pressthecontactblockontotheoperatorandturnthe
contactblockclockwiseuntilthebayonetringclicks.
Notes for Installing the Contact Block
Checkthatthecontactblockissecurelyinstalledontheoperator.Whenthe
emergencystopswitchisproperlyassembled,thebayonetringisinplaceas
shownbelow.
pmarking
jPress
TOPmarking
kTurn
TOPmarking(contactblock)
Removing the LED Unit
PullouttheLEDunitwhilesqueezingthelatchesontheLEDunitusingtheLED
unitremovaltool(MT-101).
Latches
TOPside
SqueezetheLEDunitonthe
latchesandpullout.
Installing the LED Unit
AlignthetopoftheLEDunitwiththeTOPmarkingonthecontactblock.Pushthe
LEDunitintothecontactblock.
TOPside
Switches & Pilot Devices Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
467
800-262-IDEC (4332) USA & Canada
ø16mm XA E-Stops
Switches & Pilot Devices
Operating Instructions, continued
Wiring
1.Theapplicablewiresizeis16AWGmaximum.
2.Soldertheterminalatatemperatureof310to350°Cwithin3secondsusing
asolderingiron.Sn-Ag-Cusolderisrecommended.Whensoldering,donot
touchtheswitchwiththesolderingiron.Alsoensurethatnotensileforceis
appliedtotheterminals.Donotbendtheterminalsorapplyexcessiveforceto
theterminals.
3.Useanon-corrosiverosinux.
4.Becausetheterminalspacingisnarrow,useprotectivetubesorheatshrink-
abletubestoavoidburningofwirecoatingorshortcircuit.
PC Board Terminal Type
1.WhenmountingacontactblockonaPCboard,providesufcientrotating
spaceforthePCboardwheninstallingandremovingthecontactblock.
2.WhenmountinganXAemergencystopswitchonaPCboard,makesurethat
theoperatorissecurelyinstalled.
About PC Board and Circuit Design
1.UsePCboardsmadeofglassepoxycopper-cladlaminatedsheetsof1.6mm
inthickness,withdouble-sidedthroughholes.
2.PCboardsandcircuitsmustwithstandratedvoltageandcurrent,including
instantaneouscurrentandvoltageatswitching.
3.Theminimumapplicableloadis5VAC/DC,1mA.
4.Withinthe2.8*mmareasshowninthegurebelow,terminalstouchthePC
board,resultinginpossibleshortcircuitontheprintedcircuit.Whendesign-
ingaPCboardpattern,takethispossibilityintoconsideration.
19.8
8.7
19.8
(0.5) 1.6 (PC Board)
(0.5)
(0.5)
2.8*
2.8*
(0.5)
10-ø1.2 holes
Solder Surface
Surface for installing
components
2.8* 2.8*
Solder Surface
Surface for installing
components
8.7
Alldimensionsinmm.
Installing Insulation Terminal Cover
Toinstalltheterminalcover(XA9Z-VL2),aligntheTOPmarkingontheterminal
coverwithTOPmarkingonthecontactblock,andpresstheterminalcover
towardthecontactblock.
Note:Forwiring,insertthewiresintotheholesintheterminalcoverbeforesoldering.
Contact Bounce
Whenthebuttonisresetbypullingorturning,theNCmaincontactswillbounce.
Whenpressingthebutton,theNOmonitorcontactswillbounce.
Whendesigningacontrolcircuit,takethecontactbouncetimeintoconsider-
ation(referencevalue:20ms).
Nameplate
Whenanti-rotationisnotrequired,removetheprojectionfromthenameplate
usingpliers.
Nameplate
Handling
Donotexposetheswitchtoexcessiveshockandvibration,otherwisetheswitch
maybedeformedordamaged,causingmalfunctionoroperationfailure.
Safety Precautions
• TurnoffpowertotheXAseriesemergencystopswitchbeforestarting
installation,removal,wiring,maintenance,andinspectionoftherelays.
Failuretoturnpoweroffmaycauseelectricalshockorrehazard.
• UsetheLEDunitremovaltoolwhenreplacingtheLEDunittoavoidburning
yourhands.
• Usewiresofthepropersizetomeetthevoltageandcurrentrequirements,
andsolderthewirescorrectly.Ifsolderingisincomplete,thewiremayheat
duringoperation,causingarehazard.