Digital Panel Meters Modular Indicator and Controller for pulse signals Type UDM60 * Dual 6-DGT P-based controller with analogue indicators * Dual rate, speed, frequency and period measurement * Dual counter * 0.001% RDG basic accuracy * Range from 0.001Hz to 50kHz/20s to 1000s * Scalable inputs and counters * Linearization of the inputs up to 16 points * Special calculation functions * NPN, PNP, NAMUR, TTL, Pick-up, free of voltage contacts and AC signal inputs * Up to 4 independent alarm set-points (optional) * 20mA/10VDC analog output (optional) * Serial port RS485 or RS232 (optional) * MODBUS, JBUS communication protocol * Front protection degree: IP67, NEMA12, NEMA4x "Indoor use only" * Backlighted LCD display Product Description How to order p-based digital panel meter, dual 6-DGT LCD indicator with analogue indicators, for rate, speed, frequency and period measurements. Measuring ranges, scaling and functions easily programmable from the keypad or from the PC by Model Slot A Slot B Slot C Slot D Options means of optional UdmSoft software. UDM60 includes storage min-max functions and double level protection password. Housing for panel mounting with front protection degree: IP67, NEMA12, NEMA4x "Indoor use only". How to order UDM60 XXX XX XX X XX UdmSoft-kit UdmSoft-kit: software plus communication cable for programming UDM60 by means of PC. UdmSoft: software for programming UDM60 by means of PC, downloadable from www.carlogavazzi.com. Type Selection Slot A (measuring inputs) Slot B (communication) Slot C (communication and alarm) Slot D (power supply) TF1: XX: SX: SY: AV(*): XX: R1: H: L: TF2: 0.001Hz to 50kHz for DC signals: PNP, NPN, NAMUR, TTL, free of voltage, contacts, voltages up to 14VDC 0.001Hz to 50kHz for AC signals: pick-up, voltages up to 500VAC (*): None Serial port RS485 Serial port RS232 Single analogue output, 0 to 20mA DC and 0 to 10V DC The two analogue outputs cannot be used at the same time. It is possible to plug in only one module by instrument. None Single relay output, (AC1-8AAC, 250VAC) R2: Dual relay output, (AC1-8AAC, 250VAC) R4: Dual relay output, (AC1-8AAC, 250VAC) + dual open collector output (NPN, 100mA) R5: 4 relay outputs (AC15AAC, 250VAC) AV(*): Single analogue output, 0 to 20mA DC and 0 to 10V DC 3: 90 to 260V AC/DC 18 to 60V AC/DC (24 to 48V AC/DC 25% according to UL) 10 to 28V DC (12 to 24V DC 15% according to UL) Options XX: TX: Specifications are subject to change without notice UDM60 DS ENG 090112 None Tropicalization 1 UDM60 Input specifications Analogue inputs BQ TF1 module Channels and variables 2, 0.001Hz to 50kHz for DC signals: PNP, NPN, NAMUR, TTL, free of voltage contacts, voltages up to 14VDC. 2, 0.001Hz to 50kHz for AC signals: pick-up, voltages up to 500VAC. BQ TF2 module ON signal minimum time duration Rotation speed detection Type of input NPN (DC) PNP (DC) NAMUR (DC) TTL (DC) Free of voltage contact(DC) Voltage (AC) up to 100VAC Voltage (AC) up to 500VAC Digital inputs Number of inputs Use 0.001Hz to 50kHz, 10s. Max 1kHz, duty cycle 50%. Signal level: ON < 2VDC, OFF open collector (leakage current <=1mA). Signal level: ON >10VDC, OFF open collector (leakage current <=1mA). Signal level: ON <= 1mADC, OFF >= 2.2 mADC. Signal level: ON >4VDC, OFF<=2VDC. Input load: ON <1kohm, OFF >20kohm. Signal level: ON > 2VAC (5.65 Vpp). Signal level: ON > 9VAC (25.4 Vpp). Included in the measuring module. 1 (contact). - display HOLD command - key-pad disabling - latch alarm reset - counter(s) reset Contact reading signal Close contact resistance Open contact resistance Insulation Accuracy (display, RS485) Additional errors Humidity Magnetic field Temperature drift Display Max and min indication Measurements Up to 1 kHz From 1 kHz - latch and counter reset BQ TF1: <6 mA, <7 VDC BQ TF2: <0.25 mA, <3 VDC Max 1k. Min 100k. Non-insulated. See table "Measuring accuracy", temperature drifts and minimum/maximum indications" 0.05% RDG, 60% to 90% R.H. 0.05% RDG @ 400 A/m. See table "Measuring accuracy", temperature drifts and minimum/maximum indications" 2 lines, 6-digit + 2 analogue indicators. 7 segments. h= 10.0 mm See table "Measuring accuracy", temperature drifts and minimum/maximum indications" Zero-crossing detection. Zero-crossing detection with divisor. See table "Input impedance and overflow" See table "Input impedance and overflow" Input impedance Overloads Measurement accuracy, temp. drifts, max and min indications All accuracies and min/max indications are referred to an ambient temp. range of 25C 5C, rel. humidity 60% and scale ratio (electrical/displayed scale) equal to 1. ) Max indication Min indication ( Module Input type Accuracy Temp. drift BQ TF1 NPN (DC) PNP (DC) NAMUR (DC) TTL (DC) Free of voltage contact (DC) 0.001% RDG 3 digit 50 ppm/C 0.00000 00.0000 000.000 0000.00 00000.0 000000 9.99999 99.9999 999.999 9999.99 99999.9 999999 BQ TF2 Pick-up (AC) Voltage (AC) up to 100VAC Voltage (AC) up to 500VAC 0.001% RDG 3 digit 50 ppm/C 0.00000 00.0000 000.000 0000.00 00000.0 000000 9.99999 99.9999 999.999 9999.99 99999.9 999999 ) The min indication is -9.99999, ..., -999999 in case of "rotation speed detection" function ( 2 Specifications are subject to change without notice UDM60 DS ENG 090112 UDM60 Input impedance and overloads Module Input type Impedence Overload (continuos) Overload (1s) BQ TF1 NPN (DC) PNP (DC) NAMUR (DC) TTL (DC) Free of voltage contact (DC) 600 600 600 600 15 VAC/DC 15 VAC/DC 15 VAC/DC 15 VAC/DC 15 VAC/DC 20 VAC/DC 20 VAC/DC 20 VAC/DC 20 VAC/DC 20 VAC/DC BQ TF2 Pick-up (AC) Voltage (AC) up to 100VAC Voltage (AC) up to 500VAC 220 k 120 VAC/DC 200 VAC/DC 950 k 600 VAC/DC 600 VAC/DC Output specifications RS422/RS485 Serial output LED Connections Distance Terminalization Addresses Protocol Data (bidirectional) Dynamic (reading only) Static (reading/writing) Data format Baud rate Insulation (on request) Module: BR SX Bidirectional (static and dynamic variables). Display of data reception/transmission Multidrop, 2 or 4 wires, 1000 m Directly on the module by means of jumper 1 to 247, selectable by means of key-pad MODBUS RTU/JBUS Measurement, min value max value alarm status All programming parameters, min max reset reset of latch alarm 8 data bit, no parity, 1 stop bit selectable 4800, 9600,19200 and 38400 bit/s By means of opto-couplers 4000 V output to measuring inputs 4000 V output to power supply input (on request) Module: BR SY Bidirectional (static and dynamic variables) 3 wires, max. 15m 1 start bit, 8 data bit, no parity, 1 stop bit Selectable 4800, 9600, 19200 and 38400 bit/s Same as RS422/485 (on request) Over-range alarm, up alarm, Alarm set-point Hysteresis On-time delay Off-time delay Output status Min response time Output channels Relay output BO R1, R2, R4 rms rms RS232 Serial output Connections Distance Data format Baud rate Other features Alarm outputs Alarm type Specifications are subject to change without notice Relay output BO R5 Insulation Open collector output UDM60 DS ENG 090112 Insulation down alarm, down alarm with start-up deactivation up alarm with latch, down alarm with latch Adjustable from 0 to 100% of displayed electric range 0 to 100% of displayed range 0 to 255 s 0 to 255 s Selectable: normally energized /de-energize 500 ms, with filter excluded, without alarm activation delay 1 with module BO R1 (relay output). 2, independent with module BO R2 (2 relay outputs). 4, independent with module BO R4 (2 relay outputs + 2 open collector outputs). BO R5 (4 relay outputs) Type SPST AC 1: 8A, 250VAC DC 12: 5A, 24VDC AC 15: 2.5A, 250VAC DC 13: 2.5A, 24VDC Type SPST (NO) AC 1: 5A, 250VAC DC 12: 3A, 24VDC AC 15: 1,5A, 250VAC DC 13: 1,5A, 24VDC 4000 VRMS output to measuring input, 4000 VRMS output to power supply input. NPN transistor type VON 1.2 VDC/ max. 100 mA VOFF 30 VDC max. By means of opto-couplers 4000 VRMS output to 3 UDM60 Output specifications (cont.) Analogue output Range Scaling factor Accuracy Response time Termperature drift Load: 20 mA output 10 V output Insulation measuring input 4000 VRMS output to power supply input (on request) Module: BO AV 0 to 20 mADC, 0 to 10 VDC Programmable within the entire retransmission range; allows to manage the retransmission of all the values from 0 to 20 mA / 0 to 10V 0.2% FS (@ 25C 5C) 10 ms 200 ppm/C 700 10 k By means of opto-couplers 4000VRMS output to Notes: Excitation output Isolation measuring input 4000VRMS output to power supply input The two outputs cannot be used at the same time. 8.2 VDC 10%, max 10mA 13 VDC 10%, max 40mA 25 Vrms between aux. output and measuring inputs 4000 VRMS between aux. output and the other input/outputs Software functions Password Scaling parameters Pulse per revolution Input engineering unit Scaling Linearisation Points Range Filter Operating range Filtering coefficient 4 Numeric code max 4 dgt 2 levels of data protection. 1st level 0 to 4999 completely protected. 2nd level 5000 to 9999 access to programming is protected, while alarm set-points are directly programmable from the measuring mode. Programmable and independent per each channel (only in case of dual frequency meter), from 1 to 9999. Programmable among Hz, kHz, rpm, krpm, rph, krph, and independent per each channel (only in case of dual frequency meter). Selection of the decimal point, min value and max value of the input range (expressed in engineering units). Selection of the decimal point, min value and max value of the displayed range correspondent to the input range. Programmable and independent per each channel (only in case of dual frequency meter). Up to 16 Input value and displayed value of each point within the programmable input and display range 0 to 100% of the displayed value of channel A 1 to 32 Filter action Operating modes Displayed values Min max storage Setpoint modification Latch alarm reset Counter reset Analogue indicators Diagnostic Overflow/Underflow Display over range Electrical full scale or overload UdmSoft On measurements, serial output, analogue output See "list of selectable functions and variables" See "list of selectable functions and variables" Automatic storage (in the EEPROM) of the minimum and maximum measured values from the previous memory reset Direct access to the setpoint modification from the measuring mode (if allowed by the selected password). Direct access to the reset from the measuring mode. Direct access to the reset from the measuring mode. 11 positions (9 values between the minimum display value and the maximun display value, underflow and overflow) or speed rotation direction. Analogue indicator overflow or underflow position "EEE" indication "Err" indication Software for programming UDM60 by means of PC (Windows 95, 98se, ME, XP) by means of serial port RS485 and relevant connection cable. The software is available in English, Spanish, Italian, German, French. See also "Programming of UDM60 by means of PC". Specifications are subject to change without notice UDM60 DS ENG 090112 UDM60 General specifications Operating temperature 0C to +50C (32F to 122F) (R.H. 90% noncondensing) -10C to +60C (-14F to 140F) (R.H. 90% noncondensing) 300 VRMS to ground (500V input) See table "Insulation between input and outputs" 4000 VRMS for 1 minute Storage temperature Insulation reference voltage Insulation Dielectric strength Noise rejection NMRR CMRR EMC 40dB, 40 to 60 Hz 100 dB, 48 to 62 Hz EN61000-6-2, IEC61000-6-2 EN61000-6-3, IEC61000-6-3 Standard compliance Safety Connections Cable cross-section area Housing DIN Dimensions (WxHxD) Material Screw-type Max. 2.5 mm2; Min./Max. screws tightening torque: 0.4 Nm / 0.6 Nm 48 x 96 x 105 mm PC-ABS, self-extinguishing: UL 94 V-0 Protection degree Front IP67, NEMA12, NEMA4x "Indoor use only" IP20 Approx. 520 g (packing included) CE, cCSA UL e cRU US Screw terminals Weight Approvals EN61010-1, IEC61010-1 Supply Specifications AC/DC voltage 90 to 260V (standard) 18 to 60V (on request) (24 to 48V AC/DC 25% according to UL) 10 to 28V (on request) (12 to 24V DC 15% according to UL) DC voltage only Excitation output Insulation between inputs and outputs BQ TF1 Continuous Max 30s C on tin uo us M (8 ax .2 V) 30 s (8 .2 V) BQ TF1 (8.2V) 30VA/12W (90 to 260V) 20VA/12W (18 to 60V) 7.5W (10 to 28V) Energy consumption Specifications are subject to change without notice Meas. inputs Relay output Meas. inputs - 4kV 4kV 4kV 4kV 25V 4kV 4kV Relay Output 4kV - 2kV 4kV 4kV 4kV 4kV 4kV Static Output 4kV 2kV - 4kV 4kV 4kV 4kV 4kV Analogue Output 4kV 4kV 4kV - 4kV 4kV 4kV 4kV Serial Port 4kV 4kV 4kV 4kV - 4kV 4kV 4kV AUX p.supply 25V 4kV 4kV 4kV 4kV - 4kV 4kV 90-260VAC/ DC p..supply 4kV 4kV 4kV 4kV 4kV 4kV - - 18-60VAC/ DC p. supply 4kV 4kV 4kV 4kV 4kV 4kV - - UDM60 DS ENG 090112 Static Analogue Serial output output Port AUX 90-260VAC/ 18-60VAC/ p.supply DC p. supply DC p.supply 5 UDM60 List of selectable functions and variables Name Description Variables on display F1 Frequency meter, tachometer Scaled value of Channel A and Channel B Channel A and channel B F2 Period meter 1/A Channel A and function result F3 Speed difference A-B Channel A and function result F4 Speed error ratio (A-B)/B*100 Channel A and function result F5 Speed ratio A/B Channel A and function result F6 F7 F8 F9 F10 F11 Concentration of a liquid in a mixB/(A+B)*100 ture Scaled value of Channel A and Rotation sensing relevant rotation sensing Channel A + counter Frequency meter + counter channel A Channel A + counter Frequency meter + counter channel B Counter channel A + counter Dual counter channel B Counter channel A + counter Total and partial counter channel (A+B) Available modules Type Channel A and rotation direction (on the analogue indicator) Channel A and relevant counter Counter relevant to channel A and counter relevant to channel B Counter relevant to channel A and counter relevant to channel B Counter relevant to channel A and counter relevant to the sum of channel A and B Possible module combinations N. of channels UDM60 main unit Pulse signals input: 0.001Hz to 50kHz for DC signals Pulse signals input: 0.001Hz to 50kHz for AC signals Analogue output 0 to 20mA, 0 to 10VDC Channel A and function result Ordering code BD 60 2 BQ TF1 2 BQ TF2 1 BO AV Relay output 1 BO R1 Relay output 2 BO R2 Outputs: 2 relays + 2 open collectors 4 BO R4 Relay output 4 BO R5 RS485 Serial Port 1 BR SX RS232 Serial Port 1 BR SY Basic Unit Slot A Slot B Slot C Slot D Measuring inputs: TF1, TF2 RS485 Serial port: SX RS232 Serial port: SY Analogue output: AV (*) Relay outputs and/or open collector: R1, R2, R4, R5 Power supply: H, L, 3 (*) Up to 1 module max. Power supply 18 to 60V AC/DC BP L Power supply 90 to 260V AC/DC BP H Power supply 10 to28V DC BP 3 6 Specifications are subject to change without notice UDM60 DS ENG 090112 UDM60 Wiring diagrams BQ TF1 Fig. 1 ENCODER NPN/PNP BQ TF1 Fig. 2 Fig. 4 BQ TF1 NPN/PNP BQ TF1 Fig. 3 NPN and contact NAMUR PNP and contact BQ TF1 BQ TF1 Fig. 5 BQ TF1 Fig. 6 TTL Fig. 7 Auxiliary command Specifications are subject to change without notice UDM60 DS ENG 090112 7 UDM60 Wiring diagrams (cont.) BQ TF2 Fig. 8 BQ TF2 Fig. 9 max 500VAC max 100VAC BQ TF2 Fig. 10 Auxiliary command Wiring diagrams for power supply BP H: power supply BP L: power supply F1= 630mA T 250V 5x20mm F1= 3.15A T 250V 5x20mm BP 3: power supply F1= 3.15A T 250V 5x20mm Wiring diagrams of optional modules BO AV: analogue output (10V, 20mA DC) 8 BO R1: 1 relay output BO R2: 2 relay outputs Specifications are subject to change without notice BO R5: 4 relay outputs UDM60 DS ENG 090112 UDM60 Wiring diagrams of optional modules (cont.) BO SY: RS232 direct connection to PC by means of COM port. RS232 has no terminalization. Vcc BO R4: dual relay output + dual open collector output: the load resistances (Rc) must be designed so that the close contact current is lower than 100mA; the VDC voltage must be lower than or equal to 30VDC. VDC: power supply output Vo+: positive output (open collector transistor). GND: ground (open collector transistor). RS1,2,3...N NON terminalized network Terminalized network BR SX: RS485 4-wire connection: additional devices provided with RS485 port (indicated as RS1,2,3...N) are connected in parallel. The termination of the serial port is carried out only on the last instrument of the network. The serial module is provided with a jumper for the termination of the RS485 network as shown in the figure above. Note: particular types of cables or plants may require an external termination. For the network connections use twisted cable type AWG26. Programming UDM60 by means of PC To UDM 1 1m UDM60 is programmable by PC by means of the UdmSoft software (available on request). The user can program all parameters of UDM60 that will be subsequently uploaded and set in the instrument by the RS485 network (BR SX module) or by the RS232 connection (BR SY module). Should UDM60 be equipped without the RS485 or RS232 serial module, all programming parameters will be uploaded and set in the instrument by UdmSoft and the RS232 auxiliary serial connection (1) located on the side of the measuring input module using the special connection cable (2) available on request, as shown in the figures on the left. It is also possible to program the instrument using the dot connector (1) by means of the HyperTerminal Windows functions of a PC. 2 Note: the RS232 auxiliary port IS NOT insulated from the measuring inputs. To PC Specifications are subject to change without notice UDM60 DS ENG 090112 9 UDM60 Front panel description 3. Variable type indicators Display the type of the variables (A for channel A, B for channel B or F for function, min for valley value, max for peak value). 4. Alarm status indicators Display any alarm condition 6 5 4 3 2 5. Analogue indicators Display graphically the amplitude of the variables with respect to their selected minimum and maximum limits; display overload or underload conditions; display of the rotation direction. 1 1. Key-pad The programming of the configuration parameters and the display may be easily controlled by means of the 4 function keys. 6. Engineering unit The instrument is supplied with a complete set of self-sticking labels with the main engineering units. : to enter the programming phase and to confirm the password. : - to program values; - to select functions; - to scroll display pages. Dimensions and panel cut-out : for special functions. 11mm 2. Display Instantaneous measurements: - 2 x 6 digit (max display 999999). Alphanumeric indications by means of LCD display for: - display of configuration parameters; - the measured variables. 105mm Engineering Units 48mm 96mm 45mm -0,3/+0,6 92mm -0,3/+0,8 Panel depth: 8mm. 10 Specifications are subject to change without notice UDM60 DS ENG 090112 UDM60 Modules Input modules Output modules Scale 1:1 BQ TF1, BQ TF2 Measuring inputs BO AV Single analogue output 10V, 20mA DC Output modules BO R1 Single relay output BO R2 Dual relay output Serial port modules BR SX RS485 Serial port BO R4 Dual relay output + Dual open collector BO R5 4 relay outputs Power supply modules BR SY RS232 Serial port Specifications are subject to change without notice BP H Power supply: 60 to 260V AC/DC UDM60 DS ENG 090112 BP L Power supply: 18 to 60V AC/DC BP 3 Power supply: 10 to 28V DC 11