10CTQ150SPbF, 10CTQ150-1PbF
2
Bulletin PD-21016 05/05
www.irf.com
IF(AV) Max. Average Forward (Per Leg) 5 A 50% duty cycle @ TC = 155°C, rectangular wave form
Current * See Fig. 5 (Per Device) 10
IFSM Max. Peak One Cycle Non-Repetitive 620 5µs Sine or 3µs Rect. pulse
Surge Current (Per Leg) * See Fig. 7 115 10ms Sine or 6ms Rect. pulse
EAS Non-Repetitive Avalanche Energy 6.75 mJ TJ = 25 °C, IAS
= 0.30 Amps, L = 150 mH
(Per Leg)
IAR Repetitive Avalanche Current 0.30 A Current decaying linearly to zero in 1 µsec
(Per Leg) Frequency limited by TJ max. VA = 1.5 x VR typical
VRMax. DC Reverse Voltage (V)
VRWM Max. Working Peak Reverse Voltage (V)
Voltage Ratings
Absolute Maximum Ratings
Parameters Values Units Conditions
A
TJMax. Junction Temperature Range -55 to 175 °C
Tstg Max. Storage Temperature Range -55 to 175 °C
RthJC Max. Thermal Resistance Junction 3.50 °C/W DC operation
to Case (Per Leg)
RthJC Max. Thermal Resistance Junction 1.75 °C/W DC operation
to Case (Per Package)
RthCS Typical Thermal Resistance, Case 0.50 °C/W Mounting surface , smooth and greased
to Heatsink (only for TO-220)
wt Approximate Weight 2 (0.07) g (oz.)
T Mounting Torque Min. 6 (5)
Max. 12 (10)
Marking Device 10CTQ150S Case style D2Pak
10CTQ150-1 Case style TO-262
Thermal-Mechanical Specifications
Kg-cm
(Ibf-in)
Parameters Values Units Conditions
VFM Max. Forward Voltage Drop 0.93 V @ 5A
(Per Leg) * See Fig. 1 (1) 1.10 V @ 10A
0.73 V @ 5A
0.86 V @ 10A
IRM Max. Reverse Leakage Current 0.05 mA TJ = 25 °C
(Per Leg) * See Fig. 2 (1) 7 mA TJ = 125 °C
VF(TO) Threshold Voltage 0.468 V TJ = TJ max.
rtForward Slope Resistance 28 mΩ
CTMax. Junction Capacitance (Per Leg) 200 pF VR = 5VDC (test signal range 100Khz to 1Mhz) 25°C
LSTypical Series Inductance (Per Leg) 8.0 nH Measured lead to lead 5mm from package body
dv/dt Max. Voltage Rate of Change 10000 V/ µs (Rated VR)
TJ = 25 °C
TJ = 125 °C
Electrical Specifications
(1) Pulse Width < 300µs, Duty Cycle <2%
VR = rated VR
Parameters Values Units Conditions
150
Parameters 10CTQ150SPbF, 10CTQ150-1PbF
Following any rated
load condition and with