Type
Item PM4H-SD/SDM
100 to 240V AC, 24V ACRated operating voltage 50/60Hz common (AC operating type)
5A 250V AC (resistive load)
-g star-delta switching (Power ON-delay)
Rated frequency
Output rating
0.04, 0.1, 0.3, 0.5, 0.7s (5 time ranges selectable)
±0.3% (power off time change at the range of 0.1s to 1h)
±5%
±0.5% (at operating voltage changes between 85 to 110%)
Max. 100mΩ (at 1A 6V DC)
±2% (at 20°C ambient temp. at the range of –10 to +50°C +14 to +122°F)
Star ( ) side: Timed-out 1 Form A Delta (g) side: Timed-out 1 Form A
Instantaneous: 1 Form A (Instantaneous for SDM type only)
-g switching time
Operation time fluctuation
2×107
105 (at rated control capacity)
Mechanical
Electrical 85 to 110% of rated operating voltage (at 20°C coil temp.)Allowable operating voltage range
–10 to +50°C +14 to +122°FAmbient temperature Max. 85%RHAmbient humidity 860 to 1,060hPaAtmospheric pressure IP65 on front panel (using rubber gasket ATC18002)Protective construction 100g 3.527 oz (Pin type)
110g 3.880 oz (Screw terminal type)
Weight
Min. 294m/s2 (4 times on 3 axes)
Shock resistance Min. 980m/s2 (5 times on 3 axes)
10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes)
Vibration resistance 10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes)
Functional
Destructive
Functional
Destructive
Between live and dead metal parts
Between input and output
Between contacts of different poles *3
Between contacts of same pole
Insulation resistance (Initial value)
2,000Vrms for 1 min Between live and dead metal parts
2,000Vrms for 1 min Between input and output
2,000Vrms for 1 min Between contacts of different poles *3
1,000Vrms for 1 min Between contacts of same pole
Breakdown voltage (Initial value)
Setting error
Voltage error
Contact resistance (Initial value)
500msMin. power off time 65°C 131°FMax. temperature rise
Au flash on Silver alloyContact material
Temperature error
Contact arrangement
Operation mode
Max. 10VA (100 to 240V AC)
Max. 2.5VA (24V AC)
Rated power consumption
Rating
Time
accuracy
Note:)
Contact
Life
Electrical
function
Mechanical
function
Operating
condition
Others
Min. 100MΩ(At 500V DC)
2s to 100s, 4 time ranges switchable operation control time range
Notes:1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified at rated operating voltage, 20°C 68°F ambient tem-
perature, and 1s power off time.
2) For the 2s range, the tolerance for each specification becomes ±10ms.
3) Between contacts of different poles for SDM type only.