Series 2268 850W DC Power Supplies
GENERAL CHARACTERISTICS
PARALLEL OPERATION: Up to 4 instruments in a master/slave configuration.
SERIES OPERATION: Up to 2 instruments (with external diodes).
POWER SUPPLY RATED AC INPUT VOLTAGE/FREQUENCY: 100VAC to 240VAC, 47Hz to
63Hz.
OPERATIONAL AC INPUT VOLTAGE/FREQUENCY: 85VAC to 265VAC, continuous, sin-
gle-phase, 47Hz to 63Hz, 360Hz to 440Hz.
INPUT CURRENT (100/200VAC): 11.5/6A (850W).
INPUT POWER: 1100VA.
INRUSH CURRENT (100/200VAC): <25A (850W).
POWER FACTOR CORRECTION: 0.99 at 100/200VAC, rated output power.
EFFICIENCY17 (100/200VAC input): Model 2268-20-42: 82/85%. All other models: 83/87%.
TEMPERATURE COEFFICIENT: 100ppm/°C from rated output voltage, after a 30-minute
warm-up period.
DRIFT (8 hours): 0.05% of rated output (over an 8-hour interval with constant line, load,
and temperature, after a 30-minute warm-up period).
AUXILIARY OUTPUTS (2)18:
+5V; 0.5 A maximum recommended load current.
+15 V: 0.5 A maximum recommended load current.
ISOLATION19: 1500VAC or 2121VDC between mains terminals and accessible conductive
parts/chassis ground; output to chassis 500VAC.
DIGITAL INTERFACES:
RS‑232: 57.6 Kbps maximum data rate.
RS‑485: 57.6 Kbps maximum data rate.
LAN: 100-BaseT.
USB: USB 2.0.
GPIB: IEEE-488.2.
REAR‑PANEL CONNECTORS: Power output connectors
2268‑20‑42, 2268‑40‑21: Terminal bars with 6.5 mm (0.039 in.) diameter holes.
All Other Models: Terminal blocks.
Analog I/O Connector: 18-pin terminal block.
Isolated Analog I/O and Auxiliary Output Connector: 15-pin D-sub connector.
GPIB connector: 21-pin, female connector.
USB: USB 2.0 device.
RS‑232/RS‑485 and RS‑485 connectors: 8-pin, RJ-45 jack.
COOLING: Forced air cooling by internal fans.
OPERATING TEMPERATURE RANGE: 0° to 50°C, 100% load.
STORAGE TEMPERATURE RANGE: –20° to 70°C.
OPERATING HUMIDITY RANGE: 30% to 90% relative humidity (no condensation).
STORAGE HUMIDITY RANGE: 10% to 95% relative humidity (no condensation).
OPERATING ALTITUDE: Up to 2000m (6500 ft).
INSTALLATION CATEGORY: II (IEC 1010-1).
POLLUTION DEGREE: 2 (IEC 1010-1).
SAFETY: CSA 22.2 No. 61010-1, 60950-1-07 and UL61010-1 and UL60950-1 (2nd ed.)19. Marked
with cCSAus, CE for EMC and European Union Low Voltage Directive.
EMC: Conforms with European Union Low Voltage Directive.
DIMENSIONS: 44 mm high × 214 mm wide × 495 mm deep (1.72 in. × 8.43 in. × 19.48 in.).
WEIGHT: 5 kg (11 lb).
WARRANTY: Three (3) years.
NOTES
1. When setting 0V, using either the front panel or digital remote programming, the maximum output voltage is
≤0.2% of the rated output voltage.
2. When setting 0A, using either the front panel or digital remote programming, the maximum output current is
≤0.4% of the rated output current.
3. Maximum Output Power is the sum of: (Maximum Output Voltage × Maximum Output Current) + 10W. The 10W
is the maximum power output from the two auxiliary outputs, AUX1 (5V × 0.5A) and AUX2 (15V 0.5A).
4. From 85VAC to 132VAC or 170VAC to 265VAC, constant load.
5. From no load to full load, constant input voltage.
6. Voltage change is rated output voltage, constant input voltage.
7. Measured at 10% to 100% output voltage and full output current.
8. When using remote sense, the total of the load voltage and the load line drops must not exceed the rated
output of the power supply.
9. Calculation: ±0.1% of output voltage specification.
10. Calculation: ±0.2% of output current specification.
11. Calculation: ±0.3% of output power specification.
12. Calculation: 0.012% of full scale parameter.
13. With rated, resistive load.
14. Time for the output voltage to recover within 0.5% at its rated output for a load change 10% to 90% of rated
output current. Output set point 10% to 100%.
15. Time to provide data back to the controller using the LAN interface (does not include A/D conversion time).
16. The shutdown input has user-selectable negative logic operation from the front panel or remote digital input/
output.
17. At maximum output power.
18. Current: 0.51A minimum guaranteed, 0.72A typically available. The maximum current with these outputs
shorted is limited to 0.4A. Over-current protection (each output) is automatic, non-latching. When over-current
protection (OCP) is tripped, the auxiliary voltage folds back and will recover to nominal condition when
the over-current condition is removed (typical <0.2A). To protect external circuits attached to the auxiliary
outputs, use an appropriately rated fuse in series with the auxiliary outputs in use.
19. Double insulation on primary to secondary isolation barriers. Basic insulation primary to protective
earth ground.