667
Related Information
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other Products
DP-100
DP-M
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Conforming to
EMC Directive
The dual display means that the “current value” and the “threshold value”, it makes direct setting of threshold value
Equipped with a 30 mm 1.181 in square compact-sized dual display. Because the current value and the threshold
value can be checked at the same time, the threshold value can be set and checked smoothly without having to
switch screen modes. ON / OFF operations are still carried out while the threshold values are being set, so setting to
the same sensitivity as dial control-type sensors is possible. And naturally a key lock function is also equipped.
Digital
Auto reference
With analog
output
Current value
Threshold value
Man-hours reduced by
Man-hours reduced by 3/4
3/4
DP-100 with dual display
Previous model with single display
91.8
Note current value
Threshold value setting method
Operate MODE key
Adjust threshold value Return to RUN operation
Simply press a button
during RUN operation
3-color display (Red, Green, Orange)
The main display changes color in line with changes
in the status of output ON / OFF operation, and it also
changes color while setting is in progress. The sensor
status can therefore be understood easily, and operating
errors can be reduced.
SET: Orange OFF: Green (or Red) ON: Red (or Green)
During normal operation During setting
Main
Display
Readable digital display
12 segments are used and an alphanumeric display has
been adopted. This improves visual checking of letters
and numbers.
DP-100 SERIES
Dual 3-color display makes operation easier!
Certified
[DP-101(A)/102(A) only]
Recognition
General terms and conditions ........... F-17 Sensor selection guide ................. P.661~
General precautions ..................... P.1405 Korea’s S-mark ............................. P.1410
panasonic-electric-works.net/sunx
* UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]
* Passed the UL 991 Environment Test
SC-SU1........................................... P.917 Glossary of terms.......................... P.1373
Dual Display Digital Pressure Sensor For Gas
Dual Display Digital Pressure Sensor DP-100 SERIES
668
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other Products
DP-100
DP-M
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
APPLICATIONS
Conrming suction of electronic component
Conrming reference pressure Air-leak test for PET bottles
All models in the line-up are compound pressure types
No sensor settings are required to switch between positive pressure and negative
pressure, so that the number of registered part numbers can be decreased.
BASIC PERFORMANCE
FUNCTIONS
High performance accomplished
The low pressure type displays measurements in 0.1 kPa
at a resolution of 1/2,000 and has a response time of 2.5
ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
characteristics and ±0.1 % F.S. repeatability, giving it
high performance.
Low pressure type
For low
pressure
<
For low pressure
>
For high
pressure
DP-101
DP-102
–100 kPa 100 kPa
1 MPa
0 kPa
<
For high pressure
>
Ideal for applications such as
checking reference pressure.
Can also be used for simple
suction.
Ideal for applications such
as suction.
No mis-operations due to
vacuum breakdown occur. Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics
: ±0.5 % F.S.
Repeatability: ±0.1 % F.S.
Displays measurements in 0.1 kPa
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to the other
sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number
of changes required to instruction manuals when equipment designs are changed.
Copy function reduces man-hours and human error
Copying via wiring
+V
0 V
Comparative output 1
Comparative output 2
+V
0 V
Comparative output 1
Comparative output 2
Power supply
Slave sensorMaster sensor
Details copied
Details transmitted
Details received
The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU
SETTING mode” for basic settings, and “PRO mode”
for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
The sensor’s setting operation mode has a 3-level conguration to suit the frequency of use
Simple setting
Settings such as threshold value
adjustment and key lock operation
can be carried out while the sensor
is operating.
Basic settings such as output mode
setting and NO / NC switching can
be carried out.
MENU SETTING mode
RUN mode
High-level function settings such as
hysteresis adjustment and the copy
function can be carried out.
PRO mode
RUN mode
PRO mode
MENU SETTING mode
Special and
detailed setting
669
Dual Display Digital Pressure Sensor DP-100 SERIES
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other Products
DP-100
DP-M
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
FUNCTIONS
Equipped with two independent comparative outputs,
and separate sensing modes can be selected for each
of them. Since there are two comparative outputs, one
of the comparative outputs can even be used for alarm
output. In addition, if an output is not being used, it can
be disabled.
Equipped with independent dual output and three output modes Standard type
Comparative output 1
EASY mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
–100 kPa P-1 0 kPa P-2
Suction checking
Vacuum breakdown checking
Vacuum breakdown can also be checked during suction applications!
Reference pressure alarm output is possible during reference pressure checking!
0 kPa
Comparative output 1
hysteresis mode
Comparative output 2
EASY mode
ON
OFF
ON
OFF
Lo-1 Hi-1 P-2
Reference
pressure
checking
Alarm output
1
EASY mode
This mode is used for comparative output ON / OFF control.
H (Hysteresis)
H: Fixed
P
0
ON
OFF
Comparative output
Pressure
Notes:1)Hysteresiscanbexedtooneofeightdifferentlevels.
2) “ ”appears in the sub display for comparative output 1, and
” appears for comparative output 2.
2
Hysteresis mode
This mode is used for setting comparative output hysteresis
to the desired level and for carrying out ON / OFF control.
Lo
Hi
0
ON
OFF
Comparative output
H (Hysteresis)
H: 1 digit or more
Pressure
Note: “ ” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2.
3
Window comparator mode
This mode is used for setting comparative output ON
and OFF at pressures within the setting range.
H (Hysteresis)
H: Fixed
H (Hysteresis)
Comparative output
Lo
Hi
0
ON
OFF
Pressure
Notes:1)Hysteresiscanbexedtooneofeightdifferentlevels.
2)
” or “ ” appears in the sub display for comparative
output 1, and “ ” or “ ” appears for comparative output 2.
If the reference pressure of the device changes, the auto-reference function
partially shift the comparative output judgment level by the amount that the
reference pressure shifts, and the remote zero-adjustment function can reset
thedisplayvaluetozeroviaexternalinput.Thesefunctionsareidealfor
placeswherethereferencepressureuctuateswildly,orwherenesettings
are desired.
Equipped with auto-reference / remote zero-adjustment functions, more precise pressure management is possible with a minimum of effort
Multi-function type
With auto-reference function applied
20
15
0
–5
OK
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
When auto-reference input is applied, the reference pressure “30”
is added to the threshold level. If the reference pressure changes
to “20” or “40”, the auto-reference input compensates for this
every time by changing the threshold level, so any variation in
the filling pressure can be ignored.
30
Auto-reference input
Sets the absolute threshold level
The display remains at “30” and
only the threshold level is changed.
Threshold level before applying
auto-reference input
Trial 1
25
Time
Pressure
Trial 1
Auto-reference input value…
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
Sets the absolute threshold level
With remote zero-adjustment function applied
20
15
0
–5
OK
When remote zero-adjustment input is applied, the reference
pressure is forced to “0”. If the reference pressure changes to
“20” or “40”, the remote zero-adjustment input adjusts the
reference pressure to “0” every time the reference pressure
changes, so any variation in the filling pressure can be ignored.
30
Remote zero-adjustment input
Threshold level before applying
remote zero-adjustment input
Threshold level after applying
remote zero-adjustment input
25
Time
Pressure
Displayed when remote zero-adjustment
input is applied…
–5
The display is forced to “0”, and only the
filling pressure drop range is displayed.
0
Threshold level after applying
auto-reference input
Dual Display Digital Pressure Sensor DP-100 SERIES
670
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other Products
DP-100
DP-M
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
FUNCTIONS
The sub display can be set to indicate any other desired
values or letters apart from the threshold value. This
eliminatestheneedfortaskssuchasafxingalabelto
the device to indicate the normal pressure value.
Sub display can be customized
The DP-100 setting details appear in the digital display.
Because the settings are in numeric form that can be
easily understood, it is useful for times such as when
receiving technical support by telephone.
Setting details can be understood at a glance
1st digit: Setting status for
comparative output 1
5th digit: Response time
setting
6th digit: Display unit setting
7th digit: Display refresh rate setting
8th digit: ECO mode setting
2nd digit: Setting status for
comparative output 2
3rd digit:
Threshold value setting
4th digit: Display color setting
MOUNTING
Anexclusivemountingbracketthatissuitablefor1to6
mm 0.039 to 0.236 in panel thickness is available.
Tight installation to panels is possible
Takes up
much
less space
Tight installation is possible
Front protection
cover available
MS-DP1-3
An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available
Space savings can also be obtained if an L-shaped mounting bracket is used.
Cable can be connected with one-touch connection
* Connection cable
The accessory connector
attached cable (2 m 6.562 ft)
can be connected easily with
one-touch connection.
Commercially-available connectors can be used for
cable connections. Only the required length of cable
needs to be used, which contributes to a reduced
amount of wastage for unneeded cable.
A single mounting hole!
*
Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
• MS-DP1-1 • MS-DP1-5
Ceiling mounting Floor mounting Rear mounting
Positioning bosses for easier
mounting bracket installation
Tight installation is possible
Types without connector attached
cable are also available
DP-10-J
Environmentally
friendly
Commercially-available
parts can be used!
Commercially-available
parts can be used!
671
Dual Display Digital Pressure Sensor DP-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
M8 connector
G 1/8 male thread
M5 female thread
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)
M8 piug-in connector types are also available (for Europe)
Switch-over of the pressure port or at mounting
on the wall is possible
Rc1/8 conversion bushing improves compatibility
with the previous model
DP-11-E-P-J
For short pressure port type For short pressure port type
VARIETIES
* The illustration shows connection using an elbow joint.
The elbow joint is sold separately.
Compact size with a depth of only 30 mm 1.181 in, so
thatitcaneasilytintonarrowspaces.
Further, 10 g lighter than standard types. This reduces
the loads on movable parts such as robot arms.
Bymountingtheat
attachment to DP-10□-M(-P),
pressure port and cable can
now be pulled out in downward,
left or right directions. Flat
mounting on surfaces such as
the wall is made possible.
By equipping the push-in converter with DP-10□-M(-P),
pressure port can be converted from M5 female thread to
Rc1/8 female thread.
Bore diameter conversion to the DP2 / DP3 series is
possible.
Short pressure port type is lightweight and takes up little space DP-10-M
Standard type
Short pressure port type
Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
M5 female thread + R 1/8 male thread
Elbow joint
M5 female thread
[Material: Stainless steel (SUS)]
30 mm
1.181 in
Short pressure
port type DP-10-M
MS-DP1-7
M5 female thread Rc1/8 female thread
Conversion bushing
Flat attachment
3 possible directions to mount
MS-DP1-F
20 mm
0.787 in pitch
Previous model
Model No. Pressure port
MS-DP1-FM
MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
M5 female thread
Rc1/8 female thread
NPT1/8 female thread
G1/8 female thread
Previous model DP2 / DP3
series can be switched over to
DP-100 series.
20 mm
0.787 in pitch
Dual Display Digital Pressure Sensor DP-100 SERIES
672
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
ORDER GUIDE
Type Appearance Rated pressure
range Model No. Pressure
port Comparative output
Standard pressure port type
Asia
Standard
For low pressure
*CN-14A-C2
( )
( )
Connector attached
cable 2 m 6.562 ft
is attached.
Excluding M8 plug-in
connector type
–100.0 to +100.0 kPa DP-101 M5 female
thread
+
R 1/8
male thread
NPN open-collector transistor
For high pressure
–0.100 to +1.000 MPa DP-102
Multi-function
For low pressure
–100.0 to +100.0 kPa DP-101A
For high pressure
–0.100 to +1.000 MPa DP-102A
Europe
Standard
For low pressure
–100.0 to +100.0 kPa DP-101-E-P M5 female
thread
+
G 1/8
male thread
PNP open-collector transistor
For high pressure
–0.100 to +1.000 MPa DP-102-E-P
Multi-function
For low pressure
–100.0 to +100.0 kPa DP-101A-E-P
For high pressure
–0.100 to +1.000 MPa DP-102A-E-P
M8 plug-in connector type
Standard
For low pressure
–100.0 to +100.0 kPa DP-111-E-P-J M5 female
thread
+
G 1/8
male thread
PNP open-collector transistor
For high pressure
–0.100 to +1.000 MPa DP-112-E-P-J
Multi-function
For low pressure
–100.0 to +100.0 kPa DP-111A-E-P-J
For high pressure
–0.100 to +1.000 MPa DP-112A-E-P-J
North America
Standard
For low pressure
–100.0 to +100.0 kPa DP-101-N
M5 female
thread
+
NPT 1/8
male thread
NPN open-collector transistor
DP-101-N-P
PNP open-collector transistor
For high pressure
–0.100 to +1.000 MPa DP-102-N
NPN open-collector transistor
DP-102-N-P
PNP open-collector transistor
Multi-function
For low pressure
–100.0 to +100.0 kPa DP-101A-N
NPN open-collector transistor
DP-101A-N-P
PNP open-collector transistor
For high pressure
–0.100 to +1.000 MPa DP-102A-N
NPN open-collector transistor
DP-102A-N-P
PNP open-collector transistor
Short pressure port type
Asia
Standard
For low pressure
–100.0 to +100.0 kPa DP-101-M
M5 female
thread
NPN open-collector transistor
For high pressure
–0.100 to +1.000 MPa DP-102-M
Multi-function
For low pressure
–100.0 to +100.0 kPa DP-101A-M
For high pressure
–0.100 to +1.000 MPa DP-102A-M
Type without connector attached cable
Type without connector attached cable CN-14A-C2 is available.
Whenorderingthistype,sufx“-J” to the Model No.
(e.g.) Type without connector atlached cable of DP-101-N is “DP-101-N-J
Accessory
CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
673
Dual Display Digital Pressure Sensor DP-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
OPTIONS
Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg.Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
MS-DP1-2
MS-DP1-3
MS-DP1-4
Panel mounting bracket, Front protection cover
Front protection cover
MS-DP1-3
Panel mounting bracket
MS-DP1-2
DP-100
Panel mounting bracket MS-DP1-4
DP2-20
ñ101.3kPa
OUT2
OUT1
MODE
0-ADJ
DP2 / DP3
Insert
Remove
Remove
Mounting holes
for DP2 / DP3 series
can be used as is.
Front protection cover
DPX-04 (optional)
can be installed on
MS-DP1-4.
Designation
Model No. Description
Connector
attached cable
CN-14A-C1 Length: 1 m 3.281 ft
0.2 mm2 4-core cabtyre cable with connector
on one end
Cable outer diameter: ø3.7 mm ø0.146 in
CN-14A-C2 (Note)
Length: 2 m 6.562 ft
CN-14A-C3 Length: 3 m 9.843 ft
CN-14A-C5
Length: 5 m 16.404 ft
Connector
attached cable
(Flexiblecable)
CN-14A-R-C1
Length: 1 m 3.281 ft
0.2 mm24-coreexiblecabtyrecablewith
connector on one end
Cable outer diameter: ø3.7 mm ø0.146 in
CN-14A-R-C2
Length: 2 m 6.562 ft
CN-14A-R-C3
Length: 3 m 9.843 ft
CN-14A-R-C5
Length: 5 m 16.404 ft
M8 connector
attached cable
CN-24A-C2 Length: 2 m 6.562 ft For M8 plug-in connector type
The connector on one end
Cable outer diameter: ø4 mm ø0.157 in
CN-24A-C5
Length: 5 m 16.404 ft
Connector CN-14A Set of 10 housings and 40 contacts
Sensor mounting
bracket
MS-DP1-1 Allowssensorstobeinstalledontheooringorceiling.Multiple
sensors can also be mounted closely.
MS-DP1-5 Allows sensors to be installed on the wall. Multiple sensors can also
be mounted closely.
Panel mounting
bracket
MS-DP1-2 Allows installation to panels with thickness of 1 to 6 mm 0.039 to
0.236 in. Multiple sensors can also be mounted closely.
MS-DP1-4
Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
set-up, please use panel mounting bracket MS-DP1-2 for panel mounting.
Front protection
cover MS-DP1-3 Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
Conversion
bushing MS-DP1-7
By equipping with DP-10-M(-P), pressure port can be converted to
Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
Flat
attachment
MS-DP1-FM M5 female thread Pressure port and cable can now be pulled
out in downward, left or right directions. Flat
mounting on surfaces such as the wall is
made possible.
MS-DP1-FR Rc1/8 female thread
MS-DP1-FN
NPT1/8 female thread
MS-DP1-FE
G1/8 female thread
Copy unit SC-SU1
Copy the controller settings to other controllers.
Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series.
(ExcludingM8plug-inconnectortype).
Sensor mounting
bracket
MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-1
( )
Sensor mounting bracket
MS-DP1-1
Sensor mounting
bracket
MS-DP1-5
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-5
( )
MS-DP1-5
Connector attached cable
CN-14A-C
CN-14A-R-C
M8 connector attached cable
CN-24A-C
ø9
ø0.354 (Unit: mm in)
31.4
1.236 ø4
ø0.157
Conversion bushing
MS-DP1-7
Conversion bushing
MS-DP1-7
M5 female
thread
Rc1/8 female
thread
MS-DP1-FM MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
Flat attachment
MS-DP1-FM 15 g approx.
MS-DP1-FR/FN/FE 25 g approx.
Net weight:
Two M3 (length 8 mm 0.315 in) screws,
two M4 (length 20 mm 0.787 in) screws are attached.
Copy unit
SC-SU1
Dual Display Digital Pressure Sensor DP-100 SERIES
674
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
SPECIFICATIONS
Notes:1)Wheremeasurementconditionshavenotbeenspeciedprecisely,theconditionsusedwereanambienttemperatureof+20°C+68°F.
2)
Model Nos. of Asia type having “-M”areshortpressureporttype.ModelNos.ofNorthAmericatypehavingthesufx“-P” are PNP output type.
3) Cannot be used at the same time.
Type Standard Multi-function
For low pressure For high pressure For low pressure For high pressure
Model No.
Asia (Note 2)
DP-101(-M)(-P)DP-102(-M)(-P)DP-101A(-M)(-P)DP-102A(-M)(-P)
Europe DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P
M8 plug-in connector type
DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J
Item
North America (Note 2)
DP-101-N(-P)DP-102-N(-P)DP-101A-N(-P)DP-102A-N(-P)
Type of pressure Gauge pressure
Rated pressure range –100.0 to +100.0 kPa –0.100 to +1.000 MPa –100.0 to +100.0 kPa –0.100 to +1.000 MPa
Set pressure range
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm
2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
Pressure withstandability 500 kPa 1.5 MPa 500 kPa 1.5 MPa
Applicableuid Non-corrosive gas
Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption
Normal operation: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less at STD (Current consumption 25 mA or less at 24 V supply voltage)
480 mW or less at FULL (Current consumption 20 mA or less at 24 V supply voltage)
Comparative output
<Asia (NPN output) , North America (NPN output)>
NPN open-collector transistor
• Maximumsinkcurrent:100mA
• Applied voltage: 30 V DC or less (between comparative output and 0 V)
• Residual voltage: 2 V or less (at 100 mA sink current)
<Asia (PNP output) , Europe, North America (PNP output)>
PNP open-collector transistor
• Maximumsourcecurrent:100mA
• Applied voltage: 30 V DC or less (between comparative output and +V)
• Residual voltage: 2 V or less (at 100 mA source current)
Output operation / Output modes
NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable) (however, 2 digits when using psi unit)
Repeatability ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)
Response time
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection
Incorporated
Externalinput(Note3)
Auto-reference function /
Remote zero-adjustment
function
<Asia (NPN output) , North America
(NPN output)>
ON voltage: 0.4 V DC or less
OFF voltage: 5 to 30 V DC, or open
Inputimpedance:10kΩapprox.
Input time: 1 ms or more
<Asia (PNP output) , Europe,
North America (PNP output)>
ON voltage: 5 V to +V DC
OFF voltage: 0.6 V DC or less, or open
Inputimpedance:10kΩapprox.
Input time: 1 ms or more
Analog voltage output (Note 3)
Output voltage: 1 to 5 V DC
Zero point: within 3 V ± 5 % F.S.
Span: within 4 V ± 5 % F.S.
Linearity: within ±1 % F.S.
Outputimpedance:1kΩapprox.
Output voltage: 0.6 to 5 V
Zero point: within 1 V ± 5 % F.S.
Span: within 4.4 V ± 5 % F.S.
Linearity: within ±1 % F.S.
Outputimpedance:1kΩapprox.
Display
4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Displayable pressure
range
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
Indicator
Orange LED
Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON
Orange LED
Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting
Environmental resistance
Protection IP40 (IEC)
Ambient temperature –10to+50°C+14to+122°F,Storage:–10to+60°C+14to+140°F (No dew condensation or icing allowed)
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50MΩ,ormore,with500VDCmeggerbetweenallsupplyterminalsconnectedtogetherandenclosure
Vibration resistance
10 to 500 Hz frequency, 3 mm 0.118 inamplitudeormaximumacceleration196m/s2, in X, Y and Z directions for two hours each
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 inamplitudeormaximumacceleration49m/s2, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2acceleration(10Gapprox.)inX,YandZdirectionsforthreetimeseach
Temperature characteristics
Within±0.5%F.S.(at+20°C+68°F)
Within±1%F.S.(at+20°C+68°F)
Within±0.5%F.S.(at+20°C+68°F)
Within±1%F.S.(at+20°C+68°F)
Pressure port
Asia:M5femalethread+R(PT)1/8malethread(excludingDP--M(-P)), Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Material Enclosure:PBT(glassberreinforced),LCDdisplay:Acrylic,Pressureport:Stainlesssteel(SUS303)],
Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length
Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm
2
, or more, cable.
Weight Netweight:40gapprox.[DP-10-M(-P):30gapprox.],Grossweight:135gapprox.[DP-10-M(-P):125gapprox.]
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft):1pc.(excludingM8plug-inconnectortype)
675
Dual Display Digital Pressure Sensor DP-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
1kΩ
ZD1
D1
D2
Load
Tr1
Tr2
100mA max.
1
2
3
4
Users’ circuit Internal circuit
12 to 24 V DC
±10 %
+
(White) Analog voltage output
or External input
(Black) Comparative output 1
(Brown) +V
(Blue) 0 V
Terminal No.
Color code of connector attached cable
Sensor circuit
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram Terminal arrangement diagram
Terminal
No. Designation
1+V
2Comparative output 1
3Standard type: Comparative output 2
Multi-functiontype:AnalogvoltageoutputorExternalinput
40 V
Users’ circuit Internal circuit
D
12 to 24 V DC
±10 %
+
Load
Load
Tr1
ZD2
ZD1
Tr2
100mA max.
100mA max.
(Blue) 0 V
1
Terminal No.
Color code of connector attached cable
2
3
4
(Black)
Comparative output 1
(White) Comparative output 2
(Brown) +V
Sensor circuit
Standard type
Multi-function type
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD1: Surge absorption zener diode
Tr1, Tr2: NPN output transistor
1kΩ
Users’ circuit Internal circuit
D1
D2 12 to 24 V DC
±10 %
+
(White) Analog voltage output
or External input
Load
(Black) Comparative output 1
(Brown) +V
Tr1
5V
ZD1
Tr2
100mA max.
(Blue) 0 V
1
3
2
4
Terminal No.
Color code of connector attached cable
Sensor circuit
Symbols … D1, D2: Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1 : PNP input transistor
Tr2 : NPN output transistor
DP-10NPN output type
Users’ circuit Internal circuit
12 to 24 V DC
±10 %
+
(Black) Comparative output 1
Load
Load
(White) Comparative output 2
(Brown) +V
Tr1
ZD2
ZD1
Tr2
100mA max.
100mA max.
(Blue) 0 V
D
1
2
3
4
Terminal No.
Color code of connector attached cable
Sensor circuit
I/O circuit diagram Terminal arrangement diagram
1234
Terminal
No. Designation
1+V
2Comparative output 1
3Standard type: Comparative output 2
Multi-functiontype:AnalogvoltageoutputorExternalinput
40 V
Standard type
Multi-function type
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD1: Surge absorption zener diode
Tr1, Tr2: PNP output transistor
Symbols … D1, D2: Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1 : PNP output transistor
Tr2 : NPN input transistor
DP-10-P PNP output type
Dual Display Digital Pressure Sensor DP-100 SERIES
676
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
ZD1
D1
D2
(White) Analog voltage output
or External input
Load
(Black)
Comparative output 1
Tr1
Tr2
100 mA max.
1
4
2
3
Userscircuit Internal circuit
12 to 24 V DC
±10 %
+
(Brown) +V
(Blue) 0 V
Sensor circuit
Terminal No.
Color code of connection cable
1kΩ
12 to 24 V DC
±10 %
+
(Black) Comparative output 1
Load
Load
(White) Comparative output 2
Tr1
ZD2
ZD1
Tr2
100 mA max.
100 mA max.
(Blue) 0 V
D
1
4
2
3
Userscircuit Internal circuit
Sensor circuit
Terminal No.
Color code of connection cable
(Brown) +V
I/O circuit diagram Terminal arrangement diagram
Terminal
No. Designation
1+V
2Standard type: Comparative output 2
Multi-functiontype:AnalogvoltageoutputorExternalinput
30 V
4Comparative output 1
Standard type
Multi-function type
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD1: Surge absorption zener diode
Tr1, Tr2: PNP output transistor
Mounting
•The MS-DP1-1 sensor mounting bracket is available
separately, and it should be used for mounting. When
tightening the sensor to the sensor mounting bracket, use
a tightening torque of 0.5 N·m or less.
Sensor mounting bracket
MS-DP1-1 (Optional)
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for
MS-DP1-1
)
•The MS-DP1-2 panel mounting bracket (optional) and
the MS-DP1-3 front protection cover (optional) are also
available.
Front protection cover
MS-DP1-3
(optional)
Panel mounting bracket
MS-DP1-2
(optional)
Connection
Connector
attached cable
[CN-14A(-R)-C□]
•Do not apply stress directly to
the connection cable leader or
to the connector.
Conditions in use for CE conformity
•The DP-100 series is a CE conformity product complying
with EMC Directive. The harmonized standard with regard
to immunity that applies to this product is EN 61000-6-2
and the following condition must be met to conform to that
standard.
Conditions
•The line to connect with this sensor should be less than
30 m 98.425 ft.
PRECAUTIONS FOR PROPER USE Refer to General precautions.
I/O CIRCUIT AND WIRING DIAGRAMS
12
3
4
Symbols … D1, D2: Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1: PNP output transistor
Tr2: NPN input transistor
DP-11-E-P-J PNP output type
•Never use this product as a sensing device
for personnel protection.
•In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
•The DP-100 series is designed for use with
non-corrosive gas. It cannot be used with
liquid or corrosive gas.
677
Dual Display Digital Pressure Sensor DP-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
PRECAUTIONS FOR PROPER USE Refer to General precautions.
•The MS-DP1-4 panel mounting bracket is available when
switching from the DP2 / DP3 series.
•If connecting a commercially-available
coupling to the pressure port, attach a
12 mm 0.472 in spanner (14 mm 0.551
in spanner for DP-100-E type) to the
hexagonalsectionofthepressureport
to secure it, and tighten at a torque of
9.8 N·m or less. If it is tightened using
excessivetorque,itmaydamagethe
coupling or the pressure port.
In addition, wrap sealing tape around
the coupling when connecting it to prevent leaks.
•If connecting a commercially-available joint to the pressure
port of the DP-10□-M, hold the main unit in your hand to
steady it, and tighten to a torque of 1.0 N·m or less. If it is
tightenedtoanexcessivetorque,thejointorthemainunit
may become damaged.
•If connecting a commercially-available joint to the pressure
port of the MS-DP1-7, tighten to a torque of 9.8 N·m or less.
•Make sure to mount MS-DP1-F□ with the sensor properly.
If it is not mounted properly, air leakage may occur.
•Takecarethattheexcessivemountinganddismountingof
this product may cause deterioration of the O-ring.
•If you touch the O-ring of MS-DP1-F□, or any scratch or
dust, etc. is attached to it, air leakage may occur and the
sensing performance may deteriorate.
TakesufcientcarewhenusingandstoringMS-DP1-F□.
•The tightening torque should be 1 N·m or less when
connecting a coupling to the pressure port of MS-DP1-FM.
•When connecting the coupling to the pressure port of
MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm
0.551 in spanner and make sure that the tightening
torque is 9.8 N·m or less.
In addition, in order to prevent any leakage, wind a
sealing tape on the coupling when connecting.
•An conversion bushing is available for when using the
DP-10□-M short pressure port type. It can be used to
switch between this model and the DP2 / DP3 series. When
connecting to the pressure port, use a tightening torque of
1.0 N·m or less.
•The MS-DP1-F□atattachmentisavailable.
If using the MS-DP1-F□atattachment(optional),install
by following the procedures given below.
1
Decide the direction of this product to mount with the sensor.
2
Mount this product with the M3 female threads of the sensor
by using the attached M3 (length 8 mm 0.315 in) screws.
The tightening torque should be 0.5 N·m or less.
3
Mount this product with the mounting surface by using the attached
M4 (length 20 mm 0.787 in) screws. The tightening torque should
be 1.2 N·m or less.
Mounting Piping
Flat attachment
DP2-20
ñ101.3kPa
OUT2
OUT1
MODE
0-ADJ
Front protective cover
DPX-04 (Optional)
can be installed on
MS-DP1-4.
DP2 / DP3
DP-100
Insert
Remove
Remove
Panel mounting bracket MS-DP1-4
Mounting holes
for DP2 / DP3 series
can be used as is.
Conversion bushing MS-DP1-7
M5 female thread Rc1/8 female thread
Note: It is not possible to mount this product such
that the pressure port faces upward.
Pressure port
faces downward
Pressure port
faces leftward
Pressure port
faces rightward
Pressure port
faces upward
M3 (length 8 mm 0.315 in)
screw (Accessory)
M3 female thread
M3 female thread
Connector attached cable
Groove
M4 (length 20 mm 0.787 in)
screw (Accessory)
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
Connector attached cable
Groove
M4 (length 20 mm 0.787 in)
screw (Accessory)
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
12 mm 0.472 in
spanner
14 mm 0.551 in
spanner
Coupling (Purchase separately.)
Pressure port
14 mm 0.551 in
spanner
Note: Do not tighten the pressure port by holding the product with the spanner.
It may cause the product breakage.
Dual Display Digital Pressure Sensor DP-100 SERIES
678
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
PRECAUTIONS FOR PROPER USE Refer to General precautions.
PRO mode
•If the mode selection key is pressed and held for 5 sec. in
RUN mode, the mode will switch to PRO mode.
•If the mode selection key is pressed while a setting
is being made, the mode will switch to RUN mode. In
this case, the settings that have been changed will be
entered.
Setting item Description
Sub display switching
Changes the information in the sub display
during RUN mode operation to the desired
alphanumeric display.
Display refresh rate
switching
Changes the display refresh rate for the
pressure value displayed in the main display.
Hysteresisxvalue
switching
Sets the response time for EASY mode and
window comparator mode. (8 steps)
Linked display color
switching
(standard type only)
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
ECO mode setting Allows power consumption to be reduced by
dimming the display or turning it off.
Setting check code Allows the setting details to be checked via
codes.
Setting copy mode Allows the setting details for the master sensor
to be copied to slave sensors.
Reset setting Resets the settings to the factory settings.
ADJ.
Analog voltage
output
Auto-
reference
Remote
zero-adjustment
Comparative
output 1
Comparative
output 2
NO OFF
OFF
Comparative
output 1
P-1, Lo-1
NC NO
Comparative
output 2
Hi-1
NO NC
Comparative
output 1
P-2, Lo-2
NC NO
Comparative
output 2
Hi-2
NO NC
NC
Comparative
output 1
NC NO
Comparative
output 2
EASY
Code
Hysteresis
Window
comparator
EASY
Hysteresis
Window
comparator
Red
when ON
Green
when ON
Always
red
Always
green
1st digit
Analog voltage
output /
External input
NO / NC
switching
Comparative
output 2
output mode
Comparative
output 1
output mode
NO / NC
switching
Display
color for
main display
Threshold
value
display
Display
color linking
Standard
type only
2nd digit
Standard type
Multi-function
type
3rd digit
4th digit
2.5 ms MPa 250 ms OFF
5 ms kPa 500 ms STD
10 ms kgf/cm2 1,000 ms FULL
25 ms bar
50 ms psi
100 ms mmHg
250 ms inchHg
500 ms
1,000 ms
5,000 ms
Response time Unit switching
Display refresh rate
ECO mode
5th digit 6th digit 7th digit 8th digit
Code
Others
•Use within the rated pressure range.
•Donotapplypressureexceedingthepressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
•Donotuseduringtheinitialtransienttime(0.5sec.approx.)
after the power supply is switched on.
•Avoid dust, dirt, and steam.
•Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
•Do not insert wires, etc., into the pressure port. The diaphragm
will get damaged and correct operation shall not be maintained.
•Do not operate the keys with pointed or sharp objects.
MENU SETTING mode
•If the mode selection key is pressed and held for 2 sec. in
RUN mode, the mode will switch to MENU SETTING mode.
•If the mode selection key is pressed while a setting is being
made, the mode will switch to RUN mode. In this case, the
settings that have been changed will be entered.
Setting item Description
Comparative output 1
output mode setting Sets the output mode for comparative output 1.
Comparative output 2 output mode
setting (standard type only)
Sets the output mode for comparative output 2.
Analog voltage output /
externalinputswitching
(multi-function type only)
Allows switching between analog voltage output and
auto-reference input / remote zero-adjustment input.
NO / NC switching
Sets normally open (NO) or normally closed (NC).
Response time setting
Sets the response time.
The response time can be selected from 2.5 ms,
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500
ms, 1,000 ms and 5,000 ms.
Display color switching
for main display
Allows the color for the main display to be changed.
The colors can be set to “red / green” or “green /
red” to correspond to ON / OFF output, or it can
bexedat“red”or“green”allthetime.
Unit switching Pressure unit can be changed.
RUN mode
•This is the normal operating mode.
Setting item Description
Threshold value
setting
The threshold values for ON / OFF operation can be changed directly
by pressing the increment key (UP) and the decrement key (DOWN).
Zero-adjustment
function
This forces the pressure value display to be reset to zero when
the pressure port is open on the atmospheric pressure side.
Key lock function Stops key operations from being accepted.
Peak hold /
bottom hold function
Displaysthepeakvalueandbottomvaluefoructuating
pressure. The peak value appears in the main display,
and the bottom value appears in the sub display.
Table of codes
679
Dual Display Digital Pressure Sensor DP-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
DP-10Sensor
20
0.787
20
0.787
M3 female thread, 4 0.157
deep
M5 female thread
12
0.472
Connector
1.5
0.059
30
1.181
30
1.181 9.5
0.374
42.5
1.673
7.5
0.295
R (PT) 1/8
male thread
(North America: NPT 1/8)
25.5
1.004
Europe
G 1/8
male thread
10
0.394
7
0.276
14
0.551
Europe
DP-10-M(-P) Sensor
30
1.181
30
1.181
20
0.787
1.5
0.059
4.5
0.177
ø8.3
ø0.327
30
1.181
20
0.787
25.5
1.004
M5 female thread,
4 0.157 deep
M3 female thread,
4 0.157 deep
connector
DP-11-E-P-J Sensor
30
1.181
30
1.181
47.5
1.870
7
0.276
25.5
1.004
15
0.591
7
0.276
1.5
0.059
G 1/8 male thread
9.5
0.374
4.5
0.177
M3 female thread,
4 0.157 deep
M5 female thread
M8 connector
20
0.787
20
0.787
14
0.551
CN-14A-CCN-14A-R-CConnector attached cable (Optional, CN-14A-C2 is attached to the sensor)
35
1.378
8
0.315
50
0.969
L
ø3.7 ø0.146 cable
8
0.315
Model No. Length L
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
Length L
Dual Display Digital Pressure Sensor DP-100 SERIES
680
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
MS-DP1-1 Sensor mounting bracket (Optional)
MS-DP1-5 Sensor mounting bracket (Optional)
MS-DP1-2 MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional)
Assembly dimensions
Assembly dimensions
Assembly dimensions
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
Material: POM (Panel mounting bracket)
Polycarbonate (Front protection cover)
Mounting drawing with
DP-10□
Mounting drawing with
DP-10□-M
Mounting drawing with DP-10
When 1 unit is installed
When “n” units are installed horizontally in series When “n” units are installed vertically in series
4.2
0.165
9.5
0.374
14.5
0.571
2-R2.1 R0.083
ø2.3
ø0.091
1
0.039
22
0.866
t 2
t 0.079 20
0.787
5.5
0.217
44
1.732
R13
R0.512
13
0.512
20
0.787
30
1.181
20
0.787
2-ø3.5 ø0.138
5.3
0.209
( )
4.2
0.165
9.5
0.374
2-R2.1 R0.083
22
0.866
14.5
0.571
25.5
1.004
15
0.591
30
1.181
30
1.181 45
1.772
45
1.772
7.5
0.295
1.5
0.059
9.5
0.374
t 2
t 0.079
30
1.181
42.5
1.673
12
0.472
22.75
0.896
20
0.787
29.5
1.161
20
0.787
13.5
0.531
4.5
0.177
44.5
1.752
30
1.181
28
1.102
t 1.5
t 0.059
8.5
0.335
ø4.5
ø0.177
2-ø3.5 ø0.138
20
0.787
( )
20
0.787
4.5
0.177
28.5
1.122
49.5
1.949
ø4.5
ø
0.177
49.5
1.949
30
1.181
29.5
1.161
53.5
2.106
1.5
0.059
4.5
0.177
30
1.181
R6.75
R0.266
16
0.630
ø8.3
ø0.327
t 1.5
t0.059
28
1.102
20
0.787
34.5
1.358
20
0.787
34.5
1.358
39.3
1.547
( )
( )
8.7
0.343
7.2
0.283
11
0.433
9.5
0.374
7.5
0.295
Panel thickness dimension
1 to 6 mm 0.039 to 0.236 in
18.3
0.720
33.4
1.315
50
1.969
33.4
1.315
M3 female thread,
4 0.157 deep
Connector
Front
protection
cover
M5 female thread,
4 0.157 deep
(52 2.047 max)
12
0.472
R(PT) 1/8
male thread
View A
31 0
0.4
31
0
0.4
1.220
0
0.016
1.220 0
0.016
31 1.220 × n + 3.5 0.138 × (n-1)
55 2.165
or more
31 1.220 × n + 3.5 0.138 × (n-1)
55 2.165
or more
31 0
0.4
31 0
0.4
1.220 0
0.016
1.220 0
0.016
Panel cut-out dimensions
681
Dual Display Digital Pressure Sensor DP-100 SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
Spacer
Connector
M5 female
thread
12
0.472
56
2.205
80
3.150
36
1.417
+0.5
0
+
0.020
0
36
1.417
+0.5
0
+
0.020
0
Note: The panel tickness should be 1 to 32 mm 0.039 to 1.260 in.
Material: Panel mounting bracket body ··· Nylon 6
Panel mounting bracket ··· Stainless steel (SUS304)
Spacer ··· Cold rolled carbon steel (SPCC)(Uni-chrome plated)
Material: Brass (Nickel plated)
Weight:10gapprox.
Note: MS-DP1-FR has a
Rc1/8 female thread.
MS-DP1-FN has a
NPT1/8 female thread.
30
1.181
30
1.181
40
1.575
42.7
1.681
( )
3
0.118
36
1.417
6.5
0.256
26.5
1.043
9.7
0.382
( )
42.7
1.681
Panel thickness dimension 1 to 3.2 mm
0.039 to 0.126 in
8
0.315
Front protection cover (DPX-04)
Panel mounting
bracket body
Panel mounting
bracket
R 1/8
male thread
40
1.575
3.5
0.138 7.8
0.307
8
0.315
11 0.433 10 0.394
14
0.551
M5 male thread
Gasket
Rc
1/8
female thread
0.5
0.020
( )
15.8
0.622
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
MS-DP1-4 Panel mounting bracket (Optional)
MS-DP1-7 Conversion bushing (Optional)
MS-DP1-FM Flat attachment (Optional) MS-DP1-FR/FN/FE Flat attachment (Optional)
Assembly dimensions
Mounting drawing with DP-10
Panel cut-out dimensions
Assembly dimensions Assembly dimensions
Mounting drawing with DP-10
-M Mounting drawing with DP-10
-M
M5 female thread
8.5 0.335
20
0.787
5.5 0.217
6.5 0.256
44.5
1.752
24
0.945
44.5
1.752
2-ø4.3 ø0.169
11.5
0.453
37
1.457
17.5
0.689
11
0.433
30
1.181
24
0.945
24
0.945
30
1.181
( )
( )
Material: Enclosure···Polybutylene
terephthalate (PBT)
(Glassberreinforced)
Pressure port··· Stainless steel
(SUS303)
O-ring···Hydrogenated Nitrile
Butadiene Rubber
(H-NBR)
Weight:15gapprox.(atattachmentonly)
Two M3 (length 8 mm 0.315 in) screws, two M4
(length 20 mm 0.787 in) screws are attached.
5.5 0.217
6.5 0.256
37
1.457
11
0.433
8.5
0.335
17.5
0.689
11.5
0.453
Pressure port
G
1
/
8
female thread (Note)
20
0.787
14
0.551
13.5
0.531
Product distinguishing mark
MS-DP1-FR: 0 line
MS-DP1-FN: 1 line
MS-DP1-FE: 2 line
52.5
2.067
( )
24
0.945
( )
30
1.181
24
0.945
2-ø4.3
ø0.169
52.5
2.067
30
1.181
24
0.945
Material: Enclosure···Polybutylene terephthalate (PBT)
(Glassberreinforced)
Pressure port···Stainless steel (SUS303)
O-ring···Hydrogenated Nitrile
Butadiene Rubber (H-NBR)
Weight:25gapprox.(atattachmentonly)
Two M3 (length 8 mm 0.315 in) screws, two M4 (length
20 mm 0.787 in) screws are attached.
MEMO
682