Europe (UK): +44 (0)1384-842211 France: +33 (0)1 4305 8680 Germany +49 (0)6621 50570
132
Electrical Specifications
Input
Input Range ..........................180 to 400 VDC
or
36 to 72 VDC
or
18 to 36 VDC
Efficiency...............................83% typical (5V @ 40A);
87% typical (12V @ 18A);
87% typical (15V @ 16A)
Control
Voltage Adjust .......................90 to 110% Vo
Enable ................................... TTL compatible (low to enable)
Current Limit Adjust .............. 20 to 100% Io
Clock Input (external sync) ... 3.5 to 5Vp-p @ 1MHz ± 10%
Clock Output (inter nal clock) 4.4 to 5.5Vp-p @ 1MHz ± 0.5%
Power Good/Identification..... High (Vo) = power good
Temperature Monitor Output 10 mV/°K (2.73V = 0°C)
Output
Load Regulation....................0.3% typical down to no load
Line Regulation .....................0.1% typical
Noise/Ripple.......................... 100 mV typical (output below 5V)
2% typical (output 5V and over)
Remote sense.......................Up to 0.5V
Output Voltage
Adjust Range ........................±10% of nominal output
Transient Response ..............10% typical deviation with 300µs
recover y (25-75% full load)
Current Share Accuracy .......5% typical
Overvoltage Protection .........130% nominal Vo
Current Limit .........................115% Io max
Notes
Nominal values apply with sense pins connected and other control
pins unconnected.
Specifications subject to change without notice.
Special Features
High Efficiency - up to 87%
500 KHz fixed frequency
85°C baseplate operating
temperature (with no derating)
Low output ripple and noise
Excellent transient response
High Reliability - over 1 million hours
MTBF
Wide input voltage range
TTL compatible enable control
Parallelable
Adjustable output voltage and current
limit
Temperature monitor output
Overtemperature and short circuit
protection
Regulation to zero load
Environmental
Operating Temperature (baseplate):
-20°C to +85°C
Storage Temperature: -40°C to +105°C
Overtemperature Protection:90°C typical
MTBF: > 1 million hours (50°C baseplate)
Safety
UL UL 1950 E132002
CSA CSA22.2-234 LR53982C
CSA22.2-950
VDE IEC95020366-3336-1002 & 1008
EN 60950
CE CEMark (LVD)
AK80A
240 Watts
AK80A Economy Series
Input Voltages
24V, 48V or 300V
# of Outputs
Single
Total Power
240 Watts
http://store.iiic.cc/
Power Fax + 1 760-930-0698 133
DC/DC CONVERTERS
DC/DC CONVERTERS
ASTEC FRANCE S.A.R.L.
424 La Closerie, Mont D’est
93194 Noisy Le Grand
France
Telephone: +33 (0)1 4305 8680
Facsimile: +33 (0)1 4304 6033
ASTEC STANDARD POWER GERMANY
Robert-Heil-Str. 8
36251 Bad Hersfeld
Germany
Telephone: +49 (0)6621 50570
Facsimile: +49 (0)6621 505720
ASTEC STANDARD POWER EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: +44 (0)1384 842211
Facsimile: +44 (0)1384 843355
Load
+ SENSE
– SENSE
+ O/P
– O/P
18 to 36V
or
36 to 72V
or
180 to 400V
+ I/P
– I/P
9
81
4
Current limit adjust Output voltage adjust
Enable
(close to enable)
Temperature monitor output
(e.g. to fan control circuit)
PG/ID goes high (to Vo) to indicate power good.
Resistance between PG/ID and +O/P
with no power applied indicates nominal
O/P voltage, where 1K Ohm = 1 volt
(eg 3K3 = 3.3 V).
3
2
12
5
Input Output Control Pins
31. +ve 21. 1. +SENSE
32. –ve 22. 2. PG/ID
23. 3. V ADJ
24. 4. -SENSE
26 . 5 . S COM
27 . 6 . C SHARE
28 . 7. CLK OUT
29 . 8. CLK IN
9. ENABLE
10 . C LIM ADJ
11 . TEMP MON
12. PRI A UX
AK80A
Pin Assignment
+ve
–ve
Secondary
side
controls
Primary
side
controls
Ordering Information
Input Output Output Model Number Input Output Output Model Number
Voltage Voltage Current Voltage Voltage Current
Doc No: 1202 • Rev 11.5.98
300V 3.3V 50A AK80A-300L-033F50
300V 5V 40A AK80A-300L-050F40
300V 12V 18A AK80A-300L-120F18
300V 15V 16A AK80A-300L-150F16
300V 24V 10A AK80A-300L-240F10
48V 3.3V 50A AK80A-048L-033F50
48V 5V 40A AK80A-048L-050F40
48V 12V 18A AK80A-048L-120F18
48V 15V 16A AK80A-048L-150F16
48V 24V 10A AK80A-048L-240F10
24V 3.3V 40A AK80A-024L-033F40
24V 5V 30A AK80A-024L-050F30
24V 12V 14A AK80A-024L-120F14
24V 15V 12A AK80A-024L-150F12
24V 24V 8A AK80A-024L-240F08
THERMAL BASE PLATE
*
2 INPUT PINS 4 SECONDARY SIDE
CONTROL PINS
8 OUTPUT PINS
116.8 (4.60)
61.0 (2.40)
29
21
28
27
26
24
23
22
21
58
32
31
AMPSS™ POWER MODULE
12.7
(0.50)
34
129
8 PRIMARY SIDE
CONTROL PINS
Dimensions
Load
+ SENSE
– SENSE
C SHARE
1
4
+ SENSE
– SENSE
C SHARE
CLK OUT
5
CLK IN
+ O/P
– O/P
3
2
12
81
4
5
3
2
912
8
9
ENABLE
ENABLE
S COM
S COM
Parallel connections
Connections
Connection e xample
*Must be connected to protective earth
Please contact Astec for information on other output voltages, power ranges and configurations.
http://store.iiic.cc/