Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 1 of 10 North America only
FEATURES:
Models
Single output
Model
Max
Output
Power
(W)
Output
Voltage
Range
(V)
Output
Current
(A)
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
230
VAC
AMER150-50300CAZ
150
36-50
0-3
90-305/47-440
130-430
Constant Current
89
Constant Voltage
88
AMER150-36420CAZ
150
24-36
0-4.16
90-305/47-440
130-430
Constant Current
88
Constant Voltage
88
AMER150-24630CAZ
151.2
12-24
0-6.3
90-305/47-440
130-430
Constant Current
87
Constant Voltage
87
Add Suffix -F” No dimming option
Exceeding the maximum output power will permanently damage the converter
The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
option in this case.
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-saleAMER150-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from
conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial,
and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive
voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to
ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure
to identify excessive line surges violations prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Conditions
Typical
Maximum
Units
Current (full load)
115 VAC
2000
mA
230 VAC
1000
mA
277 VAC
900
mA
Inrush current <2ms (cold start)
115 VAC
50
A
230 VAC
75
A
277 VAC
90
A
Leakage current
I/O
0.25
mA
I/FG, O/FG
3.5
mA
Power factor
115 VAC
0.98
230 VAC
0.94
277 VAC
0.92
External fuse
Recommended slow blow type
3.5
A
Start-up time
900
ms
Constant Current or Constant Voltage LED
Driver or Converter
Over Voltage Protection
Over Current Protection
Input range 90-305VAC/47-440Hz
Waterproof Case rated IP68
High Efficiency up to 89%
Power Factor Correction
115VAC Operating temperature -50 to 75°C
230VAC Operating temperature -55 to 75°C
Dimmable via resistive
5 Year Limited Warranty
Short Circuit Protection
Click on Series name for product info on aimtec.com
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 2 of 10 North America only
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Current accuracy
±3
%
Line regulation
LL-HL
±2
%
Load regulation
0-100% load
±3
%
Ripple & Noise
200
mV p-p
Hold-up time (min)
40
ms
Current adjustment range
100-10
%
Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
Note: from 0% to 10% dimming adjustment signal instability may be present.
Isolation Specifications
Parameters
Conditions
Typical
Maximum
Units
Tested voltage
I/O
3sec
3750
VAC
I/FG
2000
VAC
O/FG
500
VAC
Isolation resistance
500 VDC
>1000
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100
KHz
Over current protection
AMER150-50300CAZ
3.07
A
AMER150-36420CAZ
4.27
AMER150-24630CAZ
6.37
Over voltage protection
Refer to Constant Current vs. Constant Voltage Mode curve
Short circuit protection
Auto recovery
Operating temperature
(See Derating Table)
(115VAC)
-50 to +75
oC
(230VAC)
-55 to +75
oC
Cold Start-up Time
-55°C
20
Sec
Maximum case temperature
100
oC
Storage temperature
-55 to +95
oC
Temperature coefficient
±0.02
% / oC
Cooling
Free air convection
Humidity
95
% RH
Case material
Aluminum
Potting
Epoxy (IP68 rated)
Wires
UL1015 18AWG Input & 14AWG Output *20CM
Weight
900
g
Dimensions (L X H X W)
7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm
MTBF
>400,000 hrs (MIL-HDBK-217F at +25°C)
Safety Specifications
Parameters
Agency approvals
CE
Standards
Designed to meet UL8750, IEC/EN60950-1 standards, EN55022, class B, EN60529(IP68)
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 3 of 10 North America only
Dimensions
59.00
(2.32)
181.00
(7.13)
47.00
(1.85)
200.00
(8.00)
200.00
(8.00)
2.30
(0.09)
End View
Top View
Side View
Input/Output Wires are 18 AWG 20cm
41.00
(1.73)
8.00
(0.32)
11.00
(0.43)
4.00
(0.16)
23.00
(0.91)
Measurements in Millimeters (inch)
Case Tolerance: ±0.5 (±0.02)
27.00
(1.06)
Tc
Wire connection:
Analog (resistive) Dimming Application Circuit
Wire
Connection
Brown
AC L
Blue
AC N
Green
Ground
Red
+V output
Black
-V Output
Blue (Dimming)
+ Vs dimming
White (Dimming)
-Vs dimming
Model Number
Maximum Pot
Value (kΩ)
AMER150-50300CAZ
16.71
AMER150-36420CAZ
26.70
AMER150-24630CAZ
11.47
AMER150-AZ
N
1st LED
+Vout
1
1
-Vout
RED
BLACK
AC
BLUE
L
BROWN
GREEN
BLUE
WHITE Pot
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 4 of 10 North America only
Analog (0-10V) Dimming Application Circuit
PWM (1KHz) Dimming Application Circuit
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 5 of 10 North America only
Derating
- 55 - 30 0 20 40 60 80 100
100
80
60
40
20
0
Safe Operating Area
Output Power (%)
Ambient Temperature º C
Free Air Convection
50°C
80°C
CV mode
CC Mode
50°C
80°C
Efficiency vs. Input Voltage & Output Current (CC mode)
AMER150-50300CAZ
115Vac, 0.6,
88.58
115Vac, 3,
89.32
230Vac, 0.6,
82.49
230Vac, 3,
90.72
277Vac, 0.6,
82.97
277Vac, 3,
90.89
(%)
(A)
Efficiency VS. Input Voltage & Output Current
115Vac
230Vac
277Vac
230VAC
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 6 of 10 North America only
AMER150-36420CAZ
AMER150-24630CAZ
115Vac, 0.84,
88.46 115Vac, 4.2,
87.98
230Vac, 0.84,
83.32
230Vac, 4.2,
90.15
277Vac, 0.84,
83.68
277Vac, 4.2,
90.48
(%)
(A)
Efficiency VS. Input Voltage & Output Current
115Vac
230Vac
277Vac
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 7 of 10 North America only
PFC value vs. Output Load Current (CC mode)
AMER150-50300CAZ
AMER150-36420CAZ
115VAC, 36, 1115VAC, 50,
0.997
230VAC, 36,
0.982
230VAC, 50,
0.988
277VAC, 36,
0.96 277VAC, 50,
0.978
297VAC, 36,
0.867 297VAC, 50,
0.851
305VAC, 36,
0.511
305VAC, 50,
0.522
(V)
PF VS. Output Voltage
115VAC
230VAC
277VAC
297VAC
305VAC
(PF)
115VAC, 24,
0.999 115VAC, 36, 1
230VAC, 24,
0.977
230VAC, 36,
0.989
277VAC, 24,
0.956
277VAC, 36,
0.977
295VAC, 24,
0.738
295VAC, 36,
0.844
305VAC, 24,
0.51
305VAC, 36,
0.527
(V)
PF VS. Output Voltage
115VAC
230VAC
277VAC
295VAC
305VAC
(PF)
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 8 of 10 North America only
AMER150-24630CAZ
Constant Current vs. Constant Voltage Mode
AMER150-50300CAZ
115VAC, 12, 1115VAC, 24, 1
230VAC, 12,
0.969
230VAC, 24,
0.991
277VAC, 12,
0.936
277VAC, 24,
0.98
297VAC, 12,
0.66
297VAC, 24,
0.823
305VAC, 12,
0.5
305VAC, 24,
0.524
(V)
PF VS. Output Voltage
115VAC
230VAC
277VAC
297VAC
305VAC
(PF)
115 & 230
Vac, 36, 3
115 & 230
Vac, 50, 3
115 & 230
Vac, 50.6, 0
115 & 230
Vac, 52, 0
(V)
(A) Constant Current Vs Constant Voltage
36
38
40
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 9 of 10 North America only
AMER150-36420CAZ
AMER150-24630CAZ
115 & 230
Vac, 24, 4.16
36
115 & 230
Vac, 36.3, 0115 & 230
Vac, 38, 0
(V)
(A) Constant Current Vs Constant Voltage
24
26
28
115 & 230
Vac, 12, 6.3
115 & 230
Vac, 24, 6.3
115 & 230
Vac, 24.3, 0
115 & 230
Vac, 26, 0
(V)
(A) Constant Current Vs Constant Voltage
12
14
16
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 052.1e R3.R 10 of 10 North America only
Output Current vs. Radj
AMER150-50300CAZ
AMER150-36420CAZ
AMER150-24630CAZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
115 & 230
Vac, 0, 0
115 & 230
Vac, 0.055,
0.3
115 & 230
Vac, 0.116,
0.6
115 & 230
Vac, 0.19, 0.9
115 & 230
Vac, 0.293,
1.2
115 & 230
Vac, 0.427,
1.5
115 & 230
Vac, 0.625,
1.8
115 & 230
Vac, 0.95, 2.1
115 & 230
Vac, 1.55, 2.4
115 & 230
Vac, 3.05, 2.7
115 & 230
Vac, 16.71, 3
(KΩ)
(A) Output Current VS. Dimming-Resistance
0
0.055
115 & 230
Vac, 0, 0
115 & 230
Vac, 0.06822,
0.416
115 & 230
Vac, 0.129,
0.832
115 & 230
Vac, 0.208,
1.248
115 & 230
Vac, 0.3107,
1.664
115 & 230
Vac, 0.4545,
2.08
115 & 230
Vac, 0.669,
2.496
115 & 230
Vac, 1.019,
2.912
115 & 230
Vac, 1.695,
3.328
115 & 230
Vac, 3.46,
3.744
115 & 230
Vac, 26.7,
4.16
K(Ω)
(A) Output Current vs. Resistance adjustment
0
0.06822
115 & 230
Vac, 0.055,
0.63
115 & 230
Vac, 0.118,
1.26
115 & 230
Vac, 0.19,
1.89
115 & 230
Vac, 0.28,
2.52
115 & 230
Vac, 0.43,
3.15
115 & 230
Vac, 0.64,
3.78
115 & 230
Vac, 0.917,
4.41
115 & 230
Vac, 1.59,
5.04
115 & 230
Vac, 3.336,
5.67
115 & 230
Vac, 11.6, 6.3
(KΩ)
(A) Output Current VS. Dimming-Resistance
0.055