SPECIFICATION CONTROL DRAWING 55A6087 me ONE CONDUCTOR CABLE, DOUBLE SHIELDED, DOUBLE JACKETED ome 6-28-96 Rewsic D This specification sheet forms a part of the latest issue of Raychem Specification SSA. COMPONENT WIRE - 55A0711 SHIELDS - TIN-COATED COPPER JACKETS - RADIATION-CROSSLINKED, MODIFIED ETFE COLOR - WHITE Ke SSN RG CABLE CONSTRUCTION DETAILS INNER INNER OUTER OUTER CONDUCTOR] siiELD | JACKET THICKNESS | SHIELD] JACKET THICKNESS | OUTSIDE DIAMETER | NOMINAL (aws) | (awe) (AWG) (ib/1000 ft) MINIMUM | NOMINAL MINIMUM | NOMINAL | NOMINAL [ MAXIMUM SSA6087-20-- | __20 36__| 006 008 33_| 006 008 136 143 19.1 S5A6087-18-- | 18 368 | .006 008 38__| _.006 008 146 153 23.1 ADDITIONAL REQUIREMENTS CABLE JACKET: Tensile Strength, 5000 Ibf/in? (minimum) (each) Elongation, 50% (minimum) (each) JACKET FLAWS: Impulse Dielectric Test, 6.0 kV (peak) SHIELD COVERAGE: 85% (minimum) (each) VOLTAGE WITHSTAND: 1500 volts (rms) conductor to shield for 1 minute 500 volts (rms) shield to shield for 1 minute CABLE IDENTIFICATION: Outer jacket shail be marked in green ink at 6 in. (nominal) intervals between marks as follows: SSAGO87-AWG-06090" CAPACITANCE: Center conductor to first shield, 70 pF/ft. (maximum) at 1 MHz NOTE: Nominal values are for information only. Nominal values are not requirements. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. Raychem Raychem Corporati Pa 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED | 309 constitution Drive, Menlo Park, Califomia 94025 ge DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR 8iD. 1-800-2 Raychem Fax 1-415-361-6207