IEC inlet filters FN 9244E Excellent performance IEC inlet filter with earth line choke n n n n n n Rated currents up to 15A Superior attenuation performance Integrated earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type) Technical specifications Maximum continuous operating voltage: Operating frequency: Rated currents: Approvals by rated current: High potential test voltage: Protection category: Temperature range (operation and storage): Design corresponding to: Flammability corresponding to: MTBF @ 40C/230V (Mil-HB-217F): (CQC approval pending) Typical electrical schematic 250VAC, 50/60Hz dc to 400Hz 1 to 15A @ 50C 1 to 10A (ENEC, CQC) 1 to 15A (UL, CSA) P -> E 2000VAC for 2 sec (standard types) P -> E 2500VAC for 2 sec (B types) P -> N 1000VAC for 2 sec IP40 according to IEC 60529 -25C to +85C (25/85/21) UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 UL 94V-2 or better 2,230,000 hours Features and benefits The FN 9244E IEC inlet filter combines an Approvals Cx R 2xL1 2xCy N N` E E` P` P Load Line L2 Typical applications Superior conducted attenuation n Electrical and electronic equipment IEC inlet and mains filter with superior performance, based on chokes with high n Small to medium-sized machines and filter attenuation in a small form factor. saturation resistance and excellent thermal The FN 9244E high performance power behavior. n household equipment n Single-phase power supplies, switch-mode entry module offers additional EMI sup- n Rear/front or snap-in mounting. pression on the earth line. Choosing the n Without earth line choke see FN 9244 data n Test and measurement equipment FN 9244E product line brings you the rapid power supplies sheet. n Medical devices (MDD) n Optional medical versions (B type) n In-vitro diagnostic medical devices (IVDD) according to IEC/EN 60601-1. n Rack mounting equipment Standard IEC connector filters are a practi- n Wide mounting flanges available. cal solution helping you to pass EMI system n Custom-specific versions are available on availability of a standard filter associated with the necessary safety acceptances. approval in a short time. A wide selection on amperage ratings, output connections, mounting possibilities and filters for medical applications are designed to offer you the desired solution. For types without additional earth line choke please consult the FN 9244 data sheet. request. > Components > FN 9244E Filter selection table Filter Rated current @ 50C (25C) Leakage current* @ 250VAC/50Hz FN 9244Ex-1-06 FN 9244Ex-3-06 FN 9244Ex-6-06 FN 9244Ex-8-06 FN 9244Ex-10-06 FN 9244Ex-12-06 FN 9244Ex-15-06 FN 9244Ex-12-06HI FN 9244Ex-15-06HI [A] 1 (1.2) 3 (3.5) 6 (7.2) 8 (10.6) 10 (11.6) 12 (12) 15 (15) 12 (12) 15 (15) [A] 373 373 373 373 373 373 373 373 373 [mH] 59.53 13.45 4.1 2.3 1.02 0.58 0.4 0.58 0.4 [mH] 0.335 0.6 0.9 1.0 1.0 1.1 1.2 1.1 1.2 [F] 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 FN 9244ExR-1-06 FN 9244ExR-3-06 FN 9244ExR-6-06 FN 9244ExR-8-06 FN 9244ExR-10-06 FN 9244ExR-12-06 FN 9244ExR-15-06 FN 9244ExR-12-06HI FN 9244ExR-15-06HI 1 (1.2) 3 (3.5) 6 (7.2) 8 (10.6) 10 (11.6) 12 (12) 15 (15) 12 (12) 15 (15) 373 373 373 373 373 373 373 373 373 59.53 13.45 4.1 2.3 1.02 0.58 0.4 0.58 0.4 0.335 0.6 0.9 1.0 1.0 1.1 1.2 1.1 1.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 1000 1000 1000 1000 1000 1000 1000 1000 1000 -06 -06 -06 -06 -06 -06 -06 -06 -06 46 46 46 46 46 46 46 46 46 FN 9244ExB-1-06 FN 9244ExB-3-06 FN 9244ExB-6-06 FN 9244ExB-8-06 FN 9244ExB-10-06 FN 9244ExB-12-06 FN 9244ExB-15-06 FN 9244ExB-12-06HI FN 9244ExB-15-06HI 1 (1.2) 3 (3.5) 6 (7.2) 8 (10.6) 10 (11.6) 12 (12) 15 (15) 12 (12) 15 (15) 2 2 2 2 2 2 2 2 2 59.53 13.45 4.1 2.3 1.02 0.58 0.4 0.58 0.4 0.335 0.6 0.9 1.0 1.0 1.1 1.2 1.1 1.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 1000 1000 1000 1000 1000 1000 1000 1000 1000 -06 -06 -06 -06 -06 -06 -06 -06 -06 46 46 46 46 46 46 46 46 46 * Inductance L1 L2 Capacitance Cx Cy Resistance Output connections R Weight [nF] [k] 2.2 -06 2.2 -06 2.2 -06 2.2 -06 2.2 -06 2.2 -06 2.2 -06 2.2 -06 2.2 -06 [g] 46 46 46 46 46 46 46 46 46 Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Product selector FN 9244Exx-yy-..HI-zz Snap-in range for S version only Blank: Snap-in range 0.7 to 1.5mm 20: Snap-in range 1.5 to 2.2mm Blank: Standard IEC inlet type C14 HI: Hot IEC inlet type C16 (12 and 15A types only) 06: Faston 6.3 x 0.8mm (spade/soldering) 1 to 15: Rated current Blank: Standard version R: Bleed resistor B: Medical version (with bleed resistor and without Y2-capacitor) Blank: Standard housing with mounting flanges U: Housing with wider mounting flanges S: Snap-in version, snapper on vertical side S1: Snap-in version, snapper on horizontal side For example: FN 9244E-15-06, FN 9244ES1B-10-06-20, FN 9244ER-12-06HI, FN 9244EUB-8-06 > Components > FN 9244E Typical filter attenuation Per CISPR 17; A = 50/50 sym; B = 50/50 asym; C = 0.1/100 sym; D = 100/0.1 sym 1 and 3A types 6 to 10A types 12 and 15A types Mechanical data FN 9244E FN 9244E-HI B B 6.3 x 0.8 A C E A C J E H F G D I B 6.3 x 0.8 A 6.3 x 0.8 G A J E F D Installation B T 6.3 x 0.8 S C J E H F G Panel cut out M R D I A J E G I FN 9244EU C F G FN 9244ES1 B P J H I D FN 9244ES N 6.3 x 0.8 S S F D I > Components > FN 9244E Dimensions FN 9244E FN 9244EU FN 9244ES FN 9244ES1 A 48 51.85 29.9 29.9 B 22.5 25 22.4 22.4 C 40 0.2 40 0.2 D 46.8 46.8 46.8 46.8 E 27.8 27.8 27.8 27.8 F 5.5 5.5 5.5 5.5 G 20.1 20.1 20.1 20.1 H O3.3 O3.3 I 14 14.1 14 14 J 13.3 13.3 13.3 13.3 M R3 R3 R 1.5 R 1.5 N 21.5 21.5 20.8 21.9 P 28.5 28.5 29.4 28.5 R M3 M3 S 90 90 T* 0.7 - 1.5 0.7 - 1.5 T* 1.5 - 2.2 1.5 - 2.2 * FN 9244E-HI 48 22.5 40 0.2 46.8 27.8 5.5 20.1 O3.3 14 13.3 R3 21.5 28.5 M3 90 For selecting the panel thickness, please refer to the filter selector table. All dimensions in mm; 1 inch = 25.4mm Tolerances according: ISO 2768-m / EN 22768-m Your local partner: To find your local partner within Schaffner's global network, please go to www.schaffner.com August 2008 Headquarters Schaffner EMV AG 4542 Luterbach, Switzerland T +41 32 681 66 26 F +41 32 681 66 41 sales@schaffner.com www.schaffner.com China Schaffner EMC Ltd. Shanghai T +86 21 6813 9855 cschina@schaffner.com Sweden Schaffner EMC AB T +46 8 5792 1121 swedensales@schaffner.com To find your local partner within Schaffner`s global network, please go to Finland Schaffner Oy T +358 19 357 271 finlandsales@schaffner.com Switzerland Schaffner EMV AG T +41 32 681 66 26 sales@schaffner.ch August 2008 France Schaffner EMC S.A.S. T +33 1 34 34 30 60 francesales@schaffner.com Taiwan Schaffner EMV Ltd. T +886 2 87525050 taiwansales@schaffner.com Germany Schaffner EMV GmbH T +49 721 56910 germanysales@schaffner.com Thailand Schaffner EMC Co. Ltd. T +66 53 58 11 04 thailandsales@schaffner.com Schaffner Jacke GmbH T +49 2951 6001 0 jacke-trafo@schaffner.com UK Schaffner Ltd. T +44 118 9770070 uksales@schaffner.com Italy Schaffner EMC S.r.l. T +39 02 66 04 30 45 italysales@schaffner.com Japan Schaffner EMC K.K. T +81 3 5456 0180 japansales@schaffner.com Singapore Schaffner EMC Pte Ltd. T +65 6377 3283 singaporesales@schaffner.com USA Schaffner EMC Inc. T +1 732 225 9533 Toll free 1 800 367 5566 usasales@schaffner.com www.schaffner.com (c) 2008 Schaffner EMC. Specifications subject to change without notice. All trademarks recognized. Schaffner is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of the ISO 9001 and ISO 14001 standards. This document has been carefully checked. However, Schaffner does not assume any liability for errors or inaccuracies.