GAMMA instabus Technical Product-Information June 2012 Binary output (relay) with mounting frame UP 510/03 Product - and Applications Description 5WG1 510-2AB03 Each output of the actuator may be set to one of the following operating modes: - Normal operation - Timer operation DELTA bus wall switches or other application units (bus device) with BTI interface are plugged onto the BTI interface of the actuator. Any bus device, which can be slipped onto a bus coupling unit (BTM) UP 117, may be slipped onto this actuator. The UP 510/03 Binary output (relay) with mounting frame is a KNX device with two switching outputs and a Bus Transceiver Interface (BTI). The device is installed in a flush-mount wall box (60 mm O, depth 60 mm). The bus is connected via a bus terminal block. The actuator electronics are supplied via the bus voltage. The UP 510/03 can switch resistive loads (e.g. electrical heaters, incandescent lamps, high voltage halogen lamps), inductive loads (e.g. motor, low voltage halogen lamps with intermediate conventional transformers), or capacitive loads (e.g. low voltage halogen lamps with intermediate electronic transformers). Each actuator output may be configured independently to provide switching, manual override, forced control, logical gate, and status reporting. Furthermore, if required, time-limited switching instead of permanent switching on can be enabled for each channel via an optional "Night mode" object (e.g. for lighting while cleaning), if need be with a warning before switching off by multiple switching the output on and off (flashing). Behavior at bus voltage failure / recovery On bus voltage failure the current switching status value is saved for restoration on bus voltage recovery. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. Building site function The building site function provided ex-factory enables switching the building site lighting on and off via bus wall switches and actuators, even if these devices have not yet been commissioned with ETS. Behavior on unloading the application program When the application program is unloaded with ETS the building site function available as ex-factory default setting is activated. The device is configured and commissioned with the ETS (Engineering Tool Software) version ETS3 v3.0f or later. Application Programs The UP 510/03 Binary output (relay) needs the application program "07 B0 A2 Switching Actuator 982E01". Amongst others, the application program includes optional a switching cycle and operating hours count with threshold monitoring for each output and an integrated 8-bit scene control, in which each output can be incorporated into up to 8 scenes. Siemens AG Infrastructure and Cities Sector, Building Technologies Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg UP 510/03, page 1 / 6 (c) Siemens AG 2012 Subject to change without further notice Technical manual Update: http://www.siemens.com/gamma 2.4.2.9/1 GAMMA instabus Technical product-information June 2012 Binary output (relay) with mounting frame UP 510/03 Example of Operation Technical Data Power Supply * via the bus line (and the 230 V mains connection) * KNX bus voltage: DC 24V (DC 21...30V) via KNX/EIB bus line * KNX bus current: < 10 mA 3L Output voltage and current via BTI * DC 5V, 10mA * DC 20V, 25mA 2 1 Outputs * Number: 2 outputs ( volt free contacts) * rated voltage: AC 230V, 47 ... 63Hz * rated current: 10A resistive load * switching current at AC 230V: 0,01 ... 10A resistive load * switching current at DC 24V: - 10A resistive load - 4A inductive load (L/R = 7ms) * Switching characteristic: set in parameter list according to application program figure 1: Example of operation Installation instructions * The device may be used for permanent interior installations in dry locations within flush-mount boxes. V DANGER * The device must be mounted and commissioned by an authorized electrician. * A safety disconnection of the device must be possible. * The device may be mounted to switch and socket combination box mounts provided VDE-certified devices are used exclusively. * The device must not be opened. * For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. * When looping through the L-conductor, take care that the maximum permissible terminal load current of 16A is not exceeded! Technical manual Update: http://www.siemens.com/gamma 2.4.2.9/2 5WG1 510-2AB03 Switching capacity at AC 230 V * for incandescent lamp load: max. 1000W * for fluorescent lamp load (LL): - uncompensated LL, cos = 0,5: max. 500W - parallel compensated LL, cos = 1 (bei Cges <= 14F): 2 x 58W oder 3 x 36W oder 6 x 18W - Duo-configuration, cos = 1: max. 1000W - OSRAM ECG for 58W LL: max. 10 Stk. - OSRAM ECG for 36W LL: max. 15 Stk. - OSRAM ECG for 18W LL: max. 20 Stk. Control elements * 1 learning button: for switching between normal operating mode and addressing mode Display elements * 1 red LED: for monitoring bus voltage and for displaying normal mode / addressing mode UP 510/03, page 2 / 6 (c) Siemens AG 2012 Subject to change without further notice Siemens AG Infrastructure and Cities Sector, Building Technologies Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg GAMMA instabus Technical product-information June 2012 Binary output (relay) with mounting frame UP 510/03 Connections * Bus line : screwless bus connection block (red-black) 0.6...0.8 mm O single core, strip insulation 5mm * 10-pin socket (BTI): for connection of DELTA switches and wall box mounted control devices with BTI plug * Load circuit: screwless terminals 0.5 ... 2.5mm single-core, stranded or multi-core, untreated, strip insulation 9 ... 10mm 5WG1 510-2AB03 Location / Function of the Display and Operating Elements Physical Specifications * mounting: plastic * dimensions (L x W x D): 71 x 71 x 42 mm * weight: approx. 90 g * fire load: approx. 1200 kJ Electrical safety * Degree of pollution (according to IEC 60664-1): 2 * Type of protection (according to EN 60529): IP 20 * Overvoltage category (according to IEC 60664-1): III * Bus: safety extra low voltage SELV DC 24 V * Relay with -contact * Device complies with: EN 50428 Electromagnetic compatibility complies with EN 50428 Environmental specifications * climatic conditions: EN 50090-2-2 * ambient temperature operating: - 5 ... + 45 C * ambient temperature non-operating: - 25 ... + 70 C * relative humidity (non-condensing): 5 % bis 93 % Reliability * Failure rate: 385 fit at 40C Markings KNX EIB CE mark complies with the EMC regulations (residential and functional buildings), and low voltage regulations Siemens AG Infrastructure and Cities Sector, Building Technologies Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg figure 2: Location / function of the display and operating elements A1 LED for indicating normal operating mode (LED off) or addressing mode (LED on); returns to normal operating mode automatically after receiving the physical address A2 Learning button for switching between normal operating mode and addressing mode and for receiving the physical address A3 Type label (with space for physical address of the actuator) A4 clamping slots for anchoring the bus lines A5 Snap-on cover for bus line and single bus wires A6 Bus connection block for single core conductors with 0,6...0,8 mm O A7 Terminal Channel A A8 Distance plate A9 Terminal L A10 Distance plate A11 Terminal N A12 Label with terminal descriptions A13 Bus Transceiver Interface (BTI) socket for connecting an application unit with BTI plug A14 Identification number of the device UP 510/03, page 3 / 6 (c) Siemens AG 2012 Subject to change without further notice Technical manual Update: http://www.siemens.com/gamma 2.4.2.9/3 GAMMA instabus Technical product-information June 2012 Binary output (relay) with mounting frame UP 510/03 Mounting and Connecting General description The connection to the bus line is established via bus connection block 193 (screwless plug-in terminals for single core conductors). The application unit is slipped onto the actuator via guide and mounting clamps and, depending on the device type, fastened with screws. Note The actuator must be mounted with the Bus Transceiver Interface (BTI) situated at the bottom (see Figure 3). Thus, the application unit will be oriented properly when slid onto the BTI. Use bus devices with mounting screws only to achieve a permanently stable contact at the BTI. Mounting B1 B2 B3 B4 B5 wall box (60 mm O, according to DIN 49073) mounting slots Bus Transceiver Interface (BTI) Actuator mounting screws of the box 5WG1 510-2AB03 - Carefully put the screw driver to the wire insertion slit of the bus connection block's grey component (C2.2) and - pull the bus connection block (C2) from the actuator (C3). Note Don't try to remove the bus connection block from the bottom side. There is a risk of shorting-out the device! Slipping on bus connection blocks - Slip the bus connection block (C2) onto the guide slot of the actuator (C3) and - press the bus connection block (C2) down to the stop. - press the sheathing of the cut-off insulation bus line projecting >3mm into the open clamping slot (C4). If a further bus line shall be connected break out the closed clamping slot with a screw-driver and press it into the clamping slot as described above. Press the single bus wires into the recess below the bus connection block and snap on the cover (C1) C2 C2.3 C2.2 figure 3: mounting C2.1 figure 4: Slipping off/on bus connection blocks Slipping off/on bus connection blocks The bus connection block (C2) is situated on the side of the actuator (C3). It consists of two components (C2.1 and C2.2) with four terminal contacts each. Take care not to damage the two test sockets (C2.3) by accidentally connecting them to the bus cable or with the screw driver (e.g. when attempting to unplug the bus connection block). Slipping off bus connection blocks - Put the screw-driver between the cover (C1) and the actuator (C3) from the side and lever out the cover. Technical manual Update: http://www.siemens.com/gamma 2.4.2.9/4 UP 510/03, page 4 / 6 (c) Siemens AG 2012 Subject to change without further notice Siemens AG Infrastructure and Cities Sector, Building Technologies Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg GAMMA instabus Technical product-information June 2012 Binary output (relay) with mounting frame UP 510/03 Connecting bus cables (figure 5) - The bus connection block (D2) can be used with single core conductors O 0.6...0.8 mm. - Remove approx. 5 mm of insulation from the conductor (D1) and plug it into the bus connection block (D2) (red = +, grey = -) 5WG1 510-2AB03 Dimension drawing Dimensions in mm Disconnecting bus cables (figure 5) - Unplug the bus connection block (D1) and remove the bus cable conductor (D2) while simultaneously wiggling it. figure 5: Connecting / disconnecting bus cables Connecting/disconnecting mains and load circuit: Connect wires - The load circuits are connected via screwless plug-in terminals (E1). - Remove approx. 9...10 mm of insulation from the wire (E 1.1) and plug it into the terminal (E1). - The terminals are designed for connection of two wires allowing to loop through the terminal block. Note: The maximum permissible terminal load current is 16A. Remove wires - Press the terminal interlocking of the terminal (F1) with a screw-driver and remove the wire (F2) from the terminal (F1). General Notes * The operating instructions must be handed over to the client. * A faulty device shall be returned with a Return Good Note for Service provided by the appropriate Siemens sales office. * If you have further questions concerning the product please contact our technical support. +49 (911) 895-7222 +49 (911) 895-7223 support.automation@siemens.com figure 6: Connecting / disconnecting mains and load circuit Siemens AG Infrastructure and Cities Sector, Building Technologies Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg UP 510/03, page 5 / 6 (c) Siemens AG 2012 Subject to change without further notice Technical manual Update: http://www.siemens.com/gamma 2.4.2.9/5 GAMMA instabus Technical product-information June 2012 Binary output (relay) with mounting frame UP 510/03 5WG1 510-2AB03 Space for notes: Technical manual Update: http://www.siemens.com/gamma 2.4.2.9/6 UP 510/03, page 6 / 6 (c) Siemens AG 2012 Subject to change without further notice Siemens AG Infrastructure and Cities Sector, Building Technologies Control Products and Systems P. O. Box 10 09 53, D-93009 Regensburg