26
TECS Hard-Clad Fiber
TECS Hard-Clad Fiber Specifications
Core Diameter µm 200 ± 5 300 ± 6
Clad Diameter µm 225 ± 5 325 ± 10
Buffer Diameter1 µm 500 ± 30 650 ± 30
Bandwidth @ 820nm MHz-km 20 15
Maximum Core Offset µm 5 5
Acceptance Angle (Full)
TECS 39 46˚46˚
TECS 48 57˚—
Maximum Power Capability
CW2 kW 0.2 0.5
Pulsed3 MW 1.0 2.3
Operating Temperature @ 820nm ˚C -65 to +125 -65 to +125
Proof Test Level kpsi 100 100
Minimum Bend Diameter
Recommended Short Term5 mm 20 30
Recommended Long Term6 mm 40 60
TECS 39 Fiber
Numerical aperture of 0.39 is available in two designs:
Low-OH¯ fibers for visible to near-IR transmission
High-OH¯ fibers for UV to visible transmission
TECS 48 Fiber
High numerical aperture of 0.48:
Couples over 50% more power than TECS 39 fiber
Couples over 370% more power than standard silica-clad fibers
Less critical fiber alignment requirements
Reduced bending losses
Fiber Type Numerical
Aperture4
TECS 39 Low-OH¯0.39 ± 0.02 Part Number FT-200-EMT FT-300-EMT
Stock Number 98-0400-1371-0 98-0400-1372-8
Maximum Attenuation 10 (6 typical) 10
@ 820nm (dB/km)
High-OH¯0.39 ± 0.02 Part Number FT-200-UMT FT-300-UMT
Stock Number 98-0400-1303-3 98-0400-1304-1
Maximum Attenuation 12 12
@ 820nm (dB/km)
TECS 48* High-OH¯0.48 ± 0.03 Part Number FT-200-URT
Stock Number 98-0400-1335-5
Maximum Attenuation 12
@ 820nm (dB/km)
27
Power-Core Fiber
400 ± 8 600 ± 10 800 ± 10 1000 ± 15 1500 ± 30
425 ± 10 630 ± 10 830 ± 10 1035 ± 15 1550 ± 31
730 ± 30 1040 ± 30 1040 ± 30 1400 ± 50 2000 ± 100
13 9 ——
79 91015
46˚46˚46˚46˚46˚
57˚57˚—57˚—
0.8 1.8 3.2 5.0 11.3
4.0 9.0 16.1 25.1 56.6
-65 to +125 -65 to +125 -65 to +125 -65 to +125 -65 to +125
100 100 100 100
40 60 80 100 150
80 120 160 200 300
1Standard buffer coating is Tefzel®210.
2Based on 1 MW/cm2 for 1064nm Nd:YAG laser and input spot size equal to 80 percent of the core diameter.
3Based on 5 GW/cm2 for 1064nm Nd:YAG laser with 10 nsec. pulse length and input spot size equal to 80 percent of the core diameter.
42 meters, 50% intensity.
5Recommended geometric strain during installation is 100% of proof test level, based on statistical analysis of fiber failures.
6Recommended geometric strain is 50% of proof test level, based on statistical analysis of fiber failures.
FT-400-EMT FT-600-EMT FT-800-EMT FT-1.0-EMT FT-1.5-EMT*
98-0400-1373-6 98-0400-1374-4 98-0400-3441-9 98-0400-1375-1 98-0400-1376-9
10 10 10 10 18
FT-400-UMT FT-600-UMT FT-800-UMT FT-1.0-UMT FT-1.5-UMT*
98-0400-1305-8 98-0400-1306-6 98-0400-1329-8 98-0400-1311-6 98-0400-1363-7
12 12 12 12 18
FT-400-URT FT-600-URT FT-1.0-URT
98-0400-1341-3 98-0400-1344-7 98-0400-1350-4
12 12 12