EEJ Series
Power Inlet Filters & Power Entry Modules
3
Cost-effective Medium Performance Power Inlet Filter
153
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
• Compact EMI filter with IEC 60320-1 C14 Inlet
• Enhanced two element circuit provides medium
attenuation to 30MHz
• Compact and cost-effective design
• Supersedes most ED Series versions
• Includes 20A version with standard IEC 60320-1
C20 inlet
• Several termination styles
• Flanged mounting
• Same performance as the EEJ Series
• Snap-in mounting
• Several termination styles
• Includes 20A version with standard IEC 60320-1
C20 inlet
• Minimal leakage current suitable for patient-
contact medical applications
• Flanged mounting the same as the EEJ Series
• Also available in snap-in versions (EJHS)
• Two element circuit provides modest EMI
attenuation above 1MHz
• Capacitive input (refer to the H Series for
capacitive output)
• EJHS models feature snap-in mounting
UL Recognized
CSA Certified
VDE Approved*
Maximum leakage current each Line to Ground:
EEJ/EJS EJH EJM
@ 120 VAC 60 Hz: .22 mA 2 A .01 mA
@250 VAC 50 Hz: .38 mA 5 A .017 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max.): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 1 to 20A*
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (T
a) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io= Ir(85-Ta)/45
Specifications
Electrical Schematic
LINE LOAD
1
Note 1: Not present in EJH versions
1
20EJH1
20EEJ8
3EEJ1
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
20A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 16A, 250VAC
• Low leakage current, suitable for most medical
applications
• Improved EMI attenuation up to 200MHz
• Mechanically the same as the EEJ Series with
flange or snap-in mounting
• EJMS models feature snap-in mounting
EJS Models
EJM & EJMS Models
EJH & EJHS Models
EEJ Series
Including the EJH/EJHS, EJM/EJMS and EJS Models
154
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
Cost-effective Medium Performance Power Inlet Filter (continued)
Available Part Numbers
EEJ Models EJH Models
1EEJ1 1EJH1
1EEJ2 1EJH2
1EEJP 1EJHP
1EEJ8 1EJH8
3EEJ1 3EJH1
3EEJ2 3EJH2
3EEJP 3EJHP
3EEJ8 3EJH8
6EEJ1 6EJH1
6EEJ2 6EJH2
6EEJP 6EJHP
6EEJ8 6EJH8
10EEJ1 10EJH1
10EEJ2 10EJH2
10EEJP 10EJHP
10EEJ8 10EJH8
15EEJ1 15EJH1
15EEJ2 15EJH2
15EEJP 15EJHP
15EEJ8 15EJH8
20EEJ1 20EJH1
20EEJ8 20EJH8
EJS Models EJHS Models
1EJS1 1EJHS1
1EJS8 1EJHS8
3EJS1 3EJHS1
3EJS8 3EJHS8
6EJS1 6EJHS1
6EJS8 6EJHS8
10EJS1 10EJHS1
10EJS8 10EJHS8
15EJS1 15EJHS1
15EJS8 15EJHS8
20EJS1
20EJS8
EJM Models EJMS Models
1EJM1 1EJMS1
1EJM8 1EJMS8
3EJM1 3EJMS1
3EJM8 3EJMS8
6EJM1 6EJMS1
6EJM8 6EJMS8
10EJM1 10EJMS1
10EJM8 10EJMS8
15EJM1 15EJMS1
15EJM8 15EJMS8
Ordering Information
3 EEJ 1
Output Styles
1 – .250 [6.3] spade terminals
(back)
2 – .250 [6.3] spade terminals
(bottom)
P – PC board pins
8 – Wire leads
Series
EEJ – Enhanced EMI Inlet Filter
EJS – EEJ in Snap-in Mounting
EJH – Enhanced Medical Inlet Filter
EJHS – EJH in Snap–in Mounting
EJM – Extended Performance
Medical Inlet Filter
EJMS – EJM in Snap-in Mounting
Current Rating
1, 3, 6, 10, 15 or 20A
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Accessories
FA601: Insulating Shroud
Dia.
.413
10.5
Dia.
.271
6.9
1.39
35.4
.118
3.0
1.17
29.7
.767
19.5
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
Cost-effective Medium Performance Power Inlet Filter (continued)
Power Inlet Filters & Power Entry Modules
3
155
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
EEJP & EJHP (1-15A)
E
D
C
AB

 

 
 
EEJ8, EJH8 & EJM8 (1-15A)
E
DB
0.96
24.39 C
A
Brown
Green/Yellow
Blue
max.
Case Styles
EEJ1, EJH1 & EJM1 (1-15A)
D
EA
B
C

 

 
 
 
EEJ2 & EJH2 (1-15A)
C
D
E
AB

 

 
 
 

 

 
   
EJS1, EJHS1 & EJMS1 (1-15A)
D
EAB
C

 
 
 
EJS8, EJHS8 & EJMS8 (1-15A)
E
DB
0.96
24.39 C
A
Brown
Green/Yellow
Blue
max.

 
   
20EEJ1 & 20EJH1
D
A
C
B
E

 

 
 
 
156
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
Cost-effective Medium Performance Power Inlet Filter (continued)
Case Styles (continued)
20EJS8
DE
A
BF
C
Brown
Green/Yellow
Blue

 
   
20EEJ8 & 20EJH8
D E
A
BF
C
Brown
Green/Yellow
Blue
20EJS1
D
E
A
F
B
C

 
 
 

 

 
   
Recommended Panel Cutouts
Tolerances ± .005 [0.13] unless otherwise noted
.140
3.56
.12
3.05
.820
20.8
1.200
30.48
1.575
40.01
.140
3.56
.234
5.94
.900
22.9
1.200
30.48
1.575
40.01
Front Mount Back Mount
R.
Typ.
R.
Typ.
1 to 15A EEJ, EJH & EJM
 
 
G
0.815
20.70
Tolerance ±.002 [.050]
0.188
4.775
RMax.
1 to 15A EJHS, EJMS & EJS

 
 
 
PC Board Layout
0.551
13.99
0.520
13.21
0.075
1.91
*±.015 [0.38]
.685*
17.40*
Tolerances ± .005 [0.13] unless otherwise noted
.138
3.51
.118
3.0
1.055
26.8
1.370
34.8
1.654
42.0
.138
3.51
.125
3.18
.985
25.02
1.300
33.0
1.654
42.0
Front Mount Back Mount
R.
Typ.
R.
Typ.
20A EEJ & EJH
 
1.450
36.83
0.125
3.175
1.053
26.75
RMax.
Tolerance ±.002 [.050]
20A EJS





EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
Cost-effective Medium Performance Power Inlet Filter (continued)
Power Inlet Filters & Power Entry Modules
3
157
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Case Dimensions
Part No. ABCDEF
   
  
EEJ1, EJH1     
    
EJM1     
    
1-10A
EEJ2, EJH2
    
    
15A
EEJ2, EJH2
    
    
1-10A
EEJP, EJHP
    
    
15A
EEJP, EJHP
    
    
EJS1, EJHS1     
    
EJMS1    
   
EEJ8, EJH8     
    
EJM8     
    
EJS8,
EJHS8
    
    
EJMS8    
   
20EEJ1,
20EJH1
    
    
20EJS1     
    
20EEJ8,
20EJH8
     
     
20EJS8      
     
Performance Data
Typical Insertion Loss
1A 3A
Measured in closed 50 Ohm system
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
EEJ & EJS Models
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
6A 10A
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
100
90
80
70
60
50
40
30
20
10
0
15A 20A
0.1 1 10 30
Frequency in MHz
100
90
80
70
60
50
40
30
20
10
00.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
20EJS1 3EJS1
158
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
Cost-effective Medium Performance Power Inlet Filter (continued)
1A 3A 6A 10A
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
EJH & EJHS Models
15A 20A
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
Performance Data (continued)
Typical Insertion Loss
Measured in closed 50 Ohm system
1A 3A
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
6A 10A
15A
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
EJM & EJMS Models
Cost-effective Medium Performance Power Inlet Filter (continued)
Power Inlet Filters & Power Entry Modules
3
159
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Measured in closed 50 Ohm system
    
       
 
         
        
     
     
   
     
 
         
       
     
     

   
Differential Mode / Symmetrical (Line to Line)
    
       
  
     
     
      
      
     
      
 
         
       
     
     

   
    
        
        
       
       
     
    
    
        
         
         
         
        
         
EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models
EJM & EJMS Models
EJMS1
EJM1
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
15EJMS8 1EJM1 3EJM1 6EJM1 6EJMS8 1EJMS8 15EJM1