67 MINIATURE ENCLOSED INDUSTRIAL RELAY
UL Recognized
File No. E52197
C US
STANDARD CLASS 67 MINIATURE
INDUSTRIAL RELAYS ARE DESIGNED
FOR APPLICATIONS REQUIRING DPDT
TO 6PDT CONTACTS WHERE SPACE
AND WEIGHT ARE OF PRIME IMPORTANCE.
SHATTER RESISTANT, SEE-THRU PLASTIC
COVERS ARE UTILIZED TO PROTECT AGAINST
DUST, TAMPERING AND ELECTRICAL SHOCK.
THE 67T MODELS HAVE BIFURCATED CONTACTS
AND ARE DESIGNED FOR LOW LEVEL SWITCHING
APPLICATIONS.
STANDARD CONTACTS
(5 AMP CROSS BAR)
BIFURCATED CONTACTS
( LOW LEVEL APPLICATIONS)
UL CONTACT LOAD RATINGS TABLE
CURRENT OR
HORSE POWER
5 AMP
5 AMP
3 AMP
3 AMP
LOAD
VOLTAGE
120 VAC
28 VDC
120 VAC
28 VDC
LOAD VOLTAGE
FREQUENCY
50/60 Hz
DC
50/60 Hz
DC
TYPE OF
LOAD
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
CONTACT
CONFIGURATION
1 POLE
THRU
6 POLES
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
1500
1000
1000
1000
1000 @ 500
10
20
-40
+60
-40
+60
-40
+130
100,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.10, 0.04 x 0.01
(2.54, 1.01 x 0.25 )
22 to 40
DIELECTRIC S
DIELECTRIC STRENGTH
TRENGTH
Coil to Contacts:
Across Open Contacts:
Pole to Pole:
Contacts to Frame:
Insulation Resistance:
VIBR
VIBRA
ATION RESIS
TION RESIST
TANCE
ANCE
Functional:
SHOCK RESIS
SHOCK RESIST
TANCE
ANCE
Functional:
TEMPER
TEMPERA
ATURE
TURE
Operating, AC Lower:
Operating, AC Upper:
Operating, DC Lower:
Operating, DC Upper:
Storage, Lower:
Storage, Upper:
LIFE EXPECT
LIFE EXPECTANC
ANCY
Y
Electrical @ Rated Load (AC1):
Mechanical @ no Load :
MISCELLANEOUS
Operating Position:
Insulation Material:
Enclosure Material:
Cover Protection Category:
Terminals:
Weight:
UNITS
UNITS
V rms
V rms
V rms
V rms
megohms
minimum @VDC
gs
gs
ºC
ºC
ºC
ºC
ºC
ºC
operations
operations
94V-0
94V-0
IP
Inch (mm)
grams
COIL
COIL
Pull-in Voltage AC (50/60 Hz):<
Pull-in Voltage DC:<
Dropout Voltage AC (50/60 Hz):>
Dropout Voltage DC:>
Maximum Voltage:
Resistance:
Coil Power AC (60 Hz):
Coil Power DC:
Insulation System Per UL Standard 1446:
Duty:
CONT
CONTA
ACTS
CTS
Contact Material:
Contact Rating AC Amperes (AC1):
Contact Rating AC Voltage:
Contact Rating DC Amperes (DC1):
Contact Rating DC Voltage:
Minimum Recommended Load:
TIMING
Operate Time:
Release Time:
80
75
10
10
120
10
2.75
0.45
Class B (130 ºC)
Continuous
Silver alloy
5/3
120 / 120
5/3
28 / 28
100 @ 5 VDC
or 0.5 W
25
20
UNITS
UNITS
% of nominal
% of nominal
% of nominal
% of nominal
% of nominal
% ±
VA
W
A
V
A
V
ma
ms
ms
GENER
GENERAL SPECIFIC
AL SPECIFICA
ATIONS (@
TIONS (@ 25
25
ºC
ºC
)
)
1...44
9/04