PBX Secure Standard83240 Part number 83240033
Dimensions according to standard DIN 41 636 type F
Positive break operation mechanism according to IEC 60947-5-1 Annex K
Double break changeover switch with electrically separated circuits (form Zb)
IP 40 or IP 67 / IP 65 versions
Operating temperature between -50 and +85 °C
Long overtravel
Standard or Low level version
Part numbers
Specifications
Degree of protection mechanism - connection
Connections / Accessories
W5 + Protective cover + Lever
Electrical characteristics
Rating nominal / 250 VAC (A)
Rating nominal / 250 VDC (A)
Operatingrange/4→30VDC/AC(A)
Mechanical characteristics
Maximum operating force (N)
Minimum positive opening force (N)
Maximum rest position (mm)
Positive opening position (mm)
Maximum end of travel position (mm)
Operating temperature (°C)
Mechanical life (operations)
107
(IP40)
4x10 6
(IP 67)
Max. tightening torque (Nm)
* Values given for versions without lever (in relation to the reference dimension X0 -
See Dimensions section).
Additional characteristics
Components
Material
-
Case/cover : PC GF 20 FR. (UL 94
-
V0, GWFI 960 °C, NFF 16
-
101/102 I2F1)
- Contacts : AgNi for Standard version and AgPd for low level version
- Terminals : Brass
-
Button membrane : Silicone
- Screws : zinc protected steel (stainless steel on request)
Conformity to standards
- Construction and performance according to IEC 60947-5-1
-
Positive opening operation according to IEC 60947
-5-1 Annex K
-
Dimensions conforming to standard DIN 41 636 type F
- Insulation characteristics according to standard IEC 60947-5-1
* Impulse withstand voltage : Uimp = 4 KV
* Rated insulation voltage : Ui = 400 V
* Pollution degree = 3
- Insulation characteristics according to standard EN 50124-1
* Impulse withstand voltage : Uimp = 2.5 KV
* Rated insulation voltage : Ui = 150 V
* Pollution degree = PD3A
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
02/11/2015 www.crouzet.com