PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
199 OPEN STYLE POWER RELAYS
UL Recognized
File No. E43641
C US
85
80
10
10
110
10
10
2
Class B (130 ยบC)
Continuous
Silver alloy,
gold flashed
1 @ 5 VDC or 5 W
40
30
2200
1500
1500
Not Applicable
1000 @ 500
-40
+50
-40
+60
-55
+100
100,000
1,000,000
Any
#6-32 combination
head screws
#8-32 combination
head screws
227 to 312
COMPLIES WITH REQUIREMENTS OF
IEC STANDARDS 947-4-1 AND
947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
CE TESTING AND EVALUATION
PERFORMED BY THE UNDERWRITERS
LABORATORIES AS A THIRD PARTY
PARTICIPANT
*
*
*
LISTED 367G
IND. CONT. EQ.
C US
FEATURES
40 AMP POWER RELAY
RATINGS TO 50 AMPS WITH
WIRE PRESSURE CONNECTOR
METAL ENCLOSURE AVAILABLE
OPTIONAL 10 AMP SPDT
AUXILIARY SWITCH
CONTACT LOAD RATINGS TABLE
SINGLE
MAKE/BREAK
CONTACTS
40 A, RESISTIVE (AC1)
5 A, RESISTIVE (AC1)
5 A, RESISTIVE (AC1)
40 A, RESISTIVE (DC1)
1 1/2 HP
15 A
960 VA
A 600
5000 A
2 HP
1152 VA
10 A
4 A
2 A
10 A (AC1)
1/4 HP
278 VA
0.4 A (DC1)
0.2 A (DC1)
3 A
COIL
COIL
Pull-in Voltage AC (50/60 Hz):<
Pull-in Voltage DC:<
Dropout Voltage AC (50/60 Hz):>
Dropout Voltage DC:>
Maximum Voltage:
Resistance Tolerance:
Coil Power AC (50/60 Hz):
Coil Power DC:
Insulation System
Per UL Standard 1446:
Duty:
CONT
CONTA
ACTS
CTS
Material:
Minimum Recommended Load:
TIMING
Operate Time @ Nominal voltage:
Release Time @ Nominal voltage:
DIELECTRIC S
DIELECTRIC STRENGTH
TRENGTH
Coil to Contacts:
Across Open Contacts:
Pole to Pole:
Contacts to Frame:
Insulation Resistance:
TEMPER
TEMPERA
ATURE
TURE
Operating, AC Lower:
Operating, AC Upper:
Operating, DC Lower:
Operating, DC Upper:
Storage, Lower:
Storage, Upper:
LIFE EXPECT
LIFE EXPECTANC
ANCY
Y
Electrical @ Rated Load (AC1):
Mechanical @ no Load :
MISCELLANEOUS
Operating Position:
Coil Terminals:
Contact Terminals:
Weight:
UNITS
UNITS
% of nominal
% of nominal
% of nominal
% of nominal
% of nominal
% ยฑ
VA
W
amps
ms
ms
V rms
V rms
V rms
V rms
megohms
minimum@VDC
ยบC
ยบC
ยบC
ยบC
ยบC
ยบC
operations
operations
grams
GENER
GENERAL SPECIFIC
AL SPECIFICA
ATIONS (@
TIONS (@ 25
25ยบC
ยบC)
)
3...4
9/04
MANUFACTURED
UNDER
ISO 9002
& QS 9000
UP TO 300 VAC 50/60HZ
480 VAC 50/60HZ
600 VAC 50/60HZ
28 VDC
MOTOR LOAD,
120 - 600 VAC 50/60HZ
TUNGSTEN,
120 VAC 50/60HZ
120 - 600 VAC 50/60HZ
NEMA PILOT DUTY 50/60HZ
SHORT CIRCUIT
DOUBLE- POLE WITH
BOTH SIDES
SWITHCHING THE LOAD
200 - 600 VAC 50/60HZ
200 - 600 VAC 50/60HZ
ADDITIONAL DC RATING
WITH MAGNETIC BLOWOUT
110 VDC
144 VDC
220 VDC
325 VDC
500 VDC
AUXILIARY SWITCH
UP TO 240 VAC 50/60HZ
MOTOR LOAD,
120- 240 VAC 50/60HZ
PILOT DUTY,
120- 240 VAC 50/60HZ
125 VDC
250 VDC
TUNGSTEN,
120 VAC 50/60 HZ
WITH WIRE PRESSURE
CONNECTORS
UP TO 300 VAC 50/60 HZ
28 VDC
DOUBLE
MAKE/BREAK
CONTACTS
40 A, RESISTIVE (AC1)
12 A, RESISTIVE (AC1)
10 A, RESISTIVE (AC1)
40 A, RESISTIVE (DC1)
2 HP
15 A
1152 VA
A 600
5000 A
20 A
15 A
8 A
4 A
2 A
10 A (AC1)
1/4 HP
278 VA
0.4 A (DC1)
0.2 A (DC1)
3 A
50 A, RESISTIVE (AC1)