PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
199 OPEN STYLE POWER RELAYS
UL Recognized
File No. E43641
C US
85
80
10
10
110
10
10
2
Class B (130 ยบC)
Continuous
Silver alloy,
gold flashed
1 @ 5 VDC or 5 W
40
30
2200
1500
1500
Not Applicable
1000 @ 500
-40
+50
-40
+60
-55
+100
100,000
1,000,000
Any
#6-32 combination
head screws
#8-32 combination
head screws
227 to 312
COMPLIES WITH REQUIREMENTS OF
IEC STANDARDS 947-4-1 AND
947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
CE TESTING AND EVALUATION
PERFORMED BY THE UNDERWRITERS
LABORATORIES AS A THIRD PARTY
PARTICIPANT
*
*
*
LISTED 367G
IND. CONT. EQ.
C US
FEATURES
40 AMP POWER RELAY
RATINGS TO 50 AMPS WITH
WIRE PRESSURE CONNECTOR
METAL ENCLOSURE AVAILABLE
OPTIONAL 10 AMP SPDT
AUXILIARY SWITCH
CONTACT LOAD RATINGS TABLE
SINGLE
MAKE/BREAK
CONTACTS
40 A, RESISTIVE (AC1)
5 A, RESISTIVE (AC1)
5 A, RESISTIVE (AC1)
40 A, RESISTIVE (DC1)
1 1/2 HP
15 A
960 VA
A 600
5000 A
2 HP
1152 VA
10 A
4 A
2 A
10 A (AC1)
1/4 HP
278 VA
0.4 A (DC1)
0.2 A (DC1)
3 A
COIL
COIL
Pull-in Voltage AC (50/60 Hz):<
Pull-in Voltage DC:<
Dropout Voltage AC (50/60 Hz):>
Dropout Voltage DC:>
Maximum Voltage:
Resistance Tolerance:
Coil Power AC (50/60 Hz):
Coil Power DC:
Insulation System
Per UL Standard 1446:
Duty:
CONT
CONTA
ACTS
CTS
Material:
Minimum Recommended Load:
TIMING
Operate Time @ Nominal voltage:
Release Time @ Nominal voltage:
DIELECTRIC S
DIELECTRIC STRENGTH
TRENGTH
Coil to Contacts:
Across Open Contacts:
Pole to Pole:
Contacts to Frame:
Insulation Resistance:
TEMPER
TEMPERA
ATURE
TURE
Operating, AC Lower:
Operating, AC Upper:
Operating, DC Lower:
Operating, DC Upper:
Storage, Lower:
Storage, Upper:
LIFE EXPECT
LIFE EXPECTANC
ANCY
Y
Electrical @ Rated Load (AC1):
Mechanical @ no Load :
MISCELLANEOUS
Operating Position:
Coil Terminals:
Contact Terminals:
Weight:
UNITS
UNITS
% of nominal
% of nominal
% of nominal
% of nominal
% of nominal
% ยฑ
VA
W
amps
ms
ms
V rms
V rms
V rms
V rms
megohms
minimum@VDC
ยบC
ยบC
ยบC
ยบC
ยบC
ยบC
operations
operations
grams
GENER
GENERAL SPECIFIC
AL SPECIFICA
ATIONS (@
TIONS (@ 25
25ยบC
ยบC)
)
3...4
9/04
MANUFACTURED
UNDER
ISO 9002
& QS 9000
UP TO 300 VAC 50/60HZ
480 VAC 50/60HZ
600 VAC 50/60HZ
28 VDC
MOTOR LOAD,
120 - 600 VAC 50/60HZ
TUNGSTEN,
120 VAC 50/60HZ
120 - 600 VAC 50/60HZ
NEMA PILOT DUTY 50/60HZ
SHORT CIRCUIT
DOUBLE- POLE WITH
BOTH SIDES
SWITHCHING THE LOAD
200 - 600 VAC 50/60HZ
200 - 600 VAC 50/60HZ
ADDITIONAL DC RATING
WITH MAGNETIC BLOWOUT
110 VDC
144 VDC
220 VDC
325 VDC
500 VDC
AUXILIARY SWITCH
UP TO 240 VAC 50/60HZ
MOTOR LOAD,
120- 240 VAC 50/60HZ
PILOT DUTY,
120- 240 VAC 50/60HZ
125 VDC
250 VDC
TUNGSTEN,
120 VAC 50/60 HZ
WITH WIRE PRESSURE
CONNECTORS
UP TO 300 VAC 50/60 HZ
28 VDC
DOUBLE
MAKE/BREAK
CONTACTS
40 A, RESISTIVE (AC1)
12 A, RESISTIVE (AC1)
10 A, RESISTIVE (AC1)
40 A, RESISTIVE (DC1)
2 HP
15 A
1152 VA
A 600
5000 A
20 A
15 A
8 A
4 A
2 A
10 A (AC1)
1/4 HP
278 VA
0.4 A (DC1)
0.2 A (DC1)
3 A
50 A, RESISTIVE (AC1)
50 A, RESISTIVE (DC1)
UP TO 50 AMPS
199 OPEN STYLE POWER RELAYS
199 SPDT
40 AMP, 1-1/2 Hp
199 DPDT
40 AMP, 1-1/2 Hp PER POLE
2 Hp -2 POLE SWITCHING
199 DPST-NO
40 AMP, 1-1/2 Hp PER POLE
2 Hp - 2 POLE SWITCHING
199 SPST-NO-DM
40 AMP, 2 Hp
199DE SPST-NO-DM
WITH BOX TERMINALS.
50 AMP, 2 Hp
2.31 MAX.
(58.67)
3.12 MAX.
(79.2)
1.62
(41.14)
1.87(47.5)
2.50 MAX.
(63.5)
2.53 MAX.
(64.3)
3.12 MAX.
(79.2)
1.62 (41.14)
1.87(47.5)
2.50 MAX.
(63.5)
MAGMETIC
BLOW OUT
MAGMETIC
BLOW OUT
3.50 MAX.
(88.9)
2.18 MAX.
(55.37)
2.43 MAX.(61.7)
1.62(41.14)
1.87(47.5)
2.50 MAX.
(63.5)
BOX TERMINAL๎™…S
50 AMP BOX TERMINALS
ACCEPT NO.14 THRU
NO. 6 AWG. WIRE
2.18 MAX.
(55.37)
2.43 MAX.
(61.7)
1.62(41.14)
1.87(47.5)
2.50 MAX.
(63.5)
199DB SPST-NO-DM
WITH MAGNETIC BLOWOUT FOR DC
ARC QUENCHING 20 AMP, 110 VDC
199B DPDT
WITH MAGNETIC BLOWOUT FOR DC
ARC QUENCHING 10 AMP, 110 VDC PER POLE
10A 1/4HP 125 OR
250VAC
.4 A 125 VDC
.2 A 250VDC
NC
NO COM
AUXILIARY SWITCH IS
INSTALLED ON
SELECTED MODELS
2.25 MAX.
(57.15)
2.43 MAX.
(61.7)
1.62 (41.14)
1.87(47.5)
2.50 MAX.
(63.5)
10A 1/4HP 125 OR
250VAC
.4 A 125 VDC
.2 A 250VDC
NC
NO COM
AUXILIARY SWITCH IS
INSTALLED ON
SELECTED MODELS
OUTLINE DIMENSIONS
DIMENSIONS SHOWN IN INCHES & (MILLIMETERS)
.
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
2.18 MAX.
(55.37)
2.43 MAX.
(61.7)
1.62 (41.14)
1.87
(47.5)
2.50 MAX.
(63.5)
MAGMETIC
BLOW OUT
2.18 MAX.
(55.37)
2.43 MAX.
(61.7)
1.62 (41.14)
1.87
(47.5)
2.50 MAX.
(63.5)
227 grams
311 grams
255 grams
227 grams
228 grams
312 grams
227 grams
3...5
9/04
WIRING DIAGRAM
(VIEWED FROM TOP)
199 OPEN STYLE POWER RELAYS
199 SPDT
40 AMP, 1-1/2 Hp
199 DPDT
40 AMP, 1-1/2 Hp PER POLE, 2 Hp-2 POLE SWITCHING
199 DPST-NO
40 AMP, 1-1/2 Hp PER POLE
2 Hp - 2 POLE SWITCHING
199 SPST-NO-DM
40 AMP, 2 Hp
199 SPST-NC-DB
40 AMP, 2 Hp
199DB SPST-NO-DM
WITH MAGNETIC BLOWOUT FOR DC ARC
QUENCHING 20 AMP, 110 VDC
STANDARD
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
NOMINAL
RESISTANCE
(OHMS)
W199AX-4
W199AX-13
W199AX-14
W199AX-15
W199AX-8
W199AX-9
W199AX-10
W199ADX-4
W199ADX-5
W199ADBX-4
W199ABX-14
W199ABMX-7
W199AMX-64
W199ADEX-4
W199X-2
W199X-3
W199X-11
W199X-12
W199X-13
W199X-14
W199X-7
W199X-8
W199DYX-2
W199DX-2
W199DX-3
W199DBX-3
W199DBX-6
W199BX-13
W199BX-14
W199BMX-13
W199MX-51
W199DEX-3
290 W
12 W
290 W
1200 W
12 W
290 W
1200 W
290 W
1200 W
290 W
290 W
290 W
290 W
290 W
70 W
290 W
18 W
70 W
290 W
6000 W
70 W
290 W
70 W
70 W
290 W
290 W
1200 W
290 W
6000 W
290 W
290 W
290 W
120 VAC 50/60 Hz
24 VAC 50/60 Hz
120 VAC 50/60 Hz
240 VAC 50/60 Hz
24 VAC 50/60 Hz
120 VAC 50/60 Hz
240 VAC
50/60 Hz
120 VAC 50/60 Hz
240 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
12 VDC
24 VDC
6 VDC
12 VDC
24 VDC
110 VDC
12 VDC
24 VDC
12 VDC
12 VDC
24 VDC
24 VDC
48 VDC
24 VDC
110 VDC
24 VDC
24 VDC
24 VDC
OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER.
CONTACT FACTORY FOR DETAILS
199DE SPST-NO-DM
WITH BOX TERMINALS.
50 AMP, 2 Hp
UP TO 50 AMPS
CONTACT
CONFIGURATION
SPDT
DPDT
DPDT
DPDT
DPST-NO
DPST-NO
DPST-NO
*SPST-NO-DM
*SPST-NO-DM
*SPST-NO-DM
(magnetic blowout)
DPDT (magnetic blowout)
DPDT (magnetic blowout)
DPDT
*SPST-NO-DM
SPDT
SPDT
DPDT
DPDT
DPDT
DPDT
DPST-NO
DPST-NO
*SPST-NC-DB
*SPST-NO-DM
*SPST-NO-DM
*SPST-NO-DM
(magnetic blowout)
*SPST-NO-DM
(magnetic blowout)
DPDT(magnetic blowout)
DPDT(magnetic blowout)
DPDT(magnetic blowout)
DPDT
*SPST-NO-DM
* REFERENCE DOUBLE MAKE/
BREAK CONTACT RATINGS
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
DOUBLE
MAKE
DOUBLE
BREAK
199B DPDT
WITH MAGNETIC BLOWOUT FOR
DC ARC QUENCHING
AUXILIARY
SWITCH
DC OPERATED
AC OPERATED
AC OPERATED WITH SPDT AUXILIARY
DC OPERATED WITH SPDT AUXILIARY
AC OPERATED WITH BOX TERMINALS
DC OPERATED WITH BOX TERMINALS
AUXILIARY
SWITCH
COIL MEASURED @ 25 ยบC
3...6
9/04