Photoelectric Sensors
382
Photoelectric ML7 Series Miniature
Pepperl+Fuchs Inc. • 1600 Enterprise Parkway • Twinsburg, Ohio 44087-2245 • www.am.pepperl-fuchs.com
Telephone (330) 486-0001 • FAX (330) 405-4710 • E-Mail: sales@us.pepperl-fuchs.com
®
PEPPERL+FUCHS
ML7 Programming
(not on ML7-8-H models)
1. With the sensor connected to the specifi ed supply
voltage, aim the sensor’s light beam at the target
for diffused mode, at the refl ector for retro-refl ective
mode, or align the transmitter and receiver for thru-
beam mode.
2. Press the teach button once. The green LED will
turn off and on again to acknowledge this step.
3. Press and hold the teach button until the green and
yellow LEDs blink simultaneously (2 Hz frequency).
The green and yellow LEDs will then blink
alternately (2 Hz frequency) to indicate an internal
set-up procedure.
If the teach is successful, both the green and yellow
LEDs should be on continuously. The green LED
indicates power is supplied to the sensor, and the
yellow LED indicates if light is received.
If the teach is not successful, then both the green and
yellow LEDs blink alternately at a faster rate (4 Hz
frequency) for about 5 seconds and the sensor will
return to its maximum sensitivity default setting. In this
case, steps 1 through 3 should be repeated.
The default setting for this series is maximum
sensitivity. If resetting the sensitivity to default is
desired, repeat steps 1 through 3 but with no target,
refl ector, or thru-beam alignment.
/102
Light On (/25)
Dark On (/59)
NPN Output
1
24
3
Male Receptacle End View
(+)
( – )
Blue
Black
Brown
(+)
( – )
1 Brown
3 Blue
4 Black Load
Load
1 Brown
3 Blue
(+)
( – )
4 Black
Load
/103
Light On (/25)
Dark On (/59)
PNP Output
1
24
3
(+)
( – )
Blue
Black
Brown
Load
Control Input*
Control Input*
*Control Input: transmitter inactive when 10-30 VDC applied
1 Brown
2 White
3 Blue
(+)
( – )
Transmitter
(thru-beam models)
1
24
3
(+)
( – )
Blue
Brown
White
102/126b
Dark On
NPN Output
1
24
3
(+)
( – )
Blue
Black
Brown
White
(+)
( – )
1 Brown
2 White
3 Blue
4 Black Load
Load
PIN 2: Weak Signal Output inactive for weak signal
Weak
Signal
Weak
Signal
82b/103
Dark On
NPN Output
1
24
3
(+)
( – )
Blue
Black
Brown
White
(+)
( – )
1 Brown
2 White
3 Blue
4 Black Load
Load
PIN 2: Weak Signal Output inactive for weak signal
Weak
Signal Weak
Signal
/102
Light On (/25)
Dark On (/59)
NPN Output
(+)
( – )
Brown
Blue
Black Load
Brown
Blue
(+)
( – )
Black
Load
/103
Light On (/25)
Dark On (/59)
PNP Output
Control Input*
*Control Input: transmitter inactive when
10-30 VDC applied
Brown
White
Blue
(+)
( – )
Transmitter
(thru-beam models)
82b/103
Dark On
NPN Output
(+)
( – )
Brown
White
Blue
Black Load
PIN 2: Weak Signal Output
inactive for weak signal
Weak
Signal
Wiring Diagrams
DC
Note: Wiring diagrams show quick
disconnect pin numbers.
Quick Disconnect
V31 Type
Cable Connection