30A high capacity relay able to withstand momentary voltage drops to 50% rated Manufactured to VDE 0435 Flame resistant materials used (UL94) High operating frequency CUR/TUV approvals GY M New od els High Capacity Relay PRICE INFORMATION AND ORDERING Options and ordering codes GY 1A 1 200/240VAC Power relay For coil voltages see table Single pole double make 1A Double pole double make 2A 1 Solder lug/push-on 2 PCB (2A version only) Specification Rated load Rated current Maximum switching voltage Maximum switching capacity Operate time Release time Maximum operate frequency Dielectric strength Ambient operating temperature Mechanical ser vice life Electrical ser vice life Contact material Voltage range Power consumption Weight GY1A Res. 30A, 250VAC/Ind. 25A,. 250VAC COS O0.4 30A GY2A Res. 25A, 250VAC/Ind. 25A, 250VAC COS O0.4 25A 277VAC 7500VA 6250VA 30ms max 30ms max 18000 ops./hour mechanical 900 ops./hour @ maximum load 4000V, 50/60Hz for 1 min (coil to contact) -55~+70C (no freezing) 5,000,000 operations min 100,000 operations min AgSnO AC80~110%, DC75~110% Approx. 1.7VA~2.7VA/1.9W Approx. 90g Coil Data Rated Voltage 12 24 100/120 200/240 AC Coils Coil res. Ohms - - - - DC Coils Rated current 138 74 18.7/22.1 9.1/10.8 Coil res. Ohms 75 300 6300 - Rated current 160 80 17.4 - GY Outline dimensions (mm) 51.5 40 34.9 8.0 40 o4.5 10.4 36.4 0.8 14.4 36.4 6.35 36 0.8 Mounting holes (mm) Wiring diagram 1A 2A o4.50.1 - 2 or 1 6 2 3 4 5 1 4 6 5 M4 Tapped holes 400.1 PCB layout (mm) 2A 17.7 14.4 1.1x3.3 - 6 36.4 Tolerance: 0.1 PRICE INFORMATION AND ORDERING