DOC-0441-010, REV A
Web Site: www.axman.com
Support: support@axman.com
DEMOACEX
Peripheral Expansion Board
Hardware User Guide
DEMOACEX USER GUIDE APRIL 3, 2008
2
CONTENTS
CAUTIONARY NOTES ..............................................................................................................3
TERMINOLOGY.........................................................................................................................3
FEATURES ................................................................................................................................4
REFERENCES...........................................................................................................................5
GETTING STARTED..................................................................................................................5
APPLICATION DEVELOPMENT...............................................................................................5
HARDWARE CONFIGURATION...............................................................................................5
POWER................................................................................................................................. 5
E-FIELD SENSOR................................................................................................................. 5
CAN PORT ............................................................................................................................ 6
USER LED’S ......................................................................................................................... 7
IO HEADER........................................................................................................................... 8
TROUBLESHOOTING................................................................................................................9
FIGURES
Figure 1: CAN_EN Option Header..............................................................................................7
Figure 2: IO Header Connector ..................................................................................................8
TABLES
Table 1 : E-Field Sensor Input Configuration.............................................................................6
Table 2: User LED’s....................................................................................................................7
REVISION
Date Rev Comments
April 3, 2008 A Initial Release.
DEMOACEX USER GUIDE APRIL 3, 2008
3
CAUTIONARY NOTES
1) Electrostatic Discharge (ESD) prevention measures should be used when handling this
product. ESD damage is not a warranty repair item.
2) Axiom Manufacturing does not assume any liability arising out of the application or use of
any product or circuit described herein; neither does it convey any license under patent
rights or the rights of others.
3) EMC Information on the DEMOACEX board:
a) This product, as shipped from the factory with associated power supplies and cables,
has been verified to meet with FCC requirements as a CLASS A product.
b) This product is designed and intended for use as a development platform for hardware
or software in an educational or professional laboratory.
c) In a domestic environment, this product may cause radio interference in which case the
user may be required to take adequate prevention measures.
d) Attaching additional wiring to this product or modifying the product operation from the
factory default as shipped may effect its performance and cause interference with other
apparatus in the immediate vicinity. If such interference is detected, suitable mitigating
measures should be taken.
TERMINOLOGY
This development board applies option selection jumpers. Terminology for application of the
option jumpers is as follows:
Jumper on, in, or installed = jumper is a plastic shunt that fits across 2 pins and the shunt is
installed so that the 2 pins are connected with the shunt.
Jumper off, out, or idle = jumper or shunt is installed so that only 1 pin holds the shunt, no 2
pins are connected, or jumper is removed. It is recommended that the jumpers be placed
idle by installing on 1 pin so they will not be lost.
Cut-Trace – a circuit trace connection between component pads. The circuit trace may be
cut using a knife to break the default connection. To reconnect the circuit, simply install a
suitably sized 0-ohm resistor or attach a wire across the pads.
Signal names followed by an asterisk (*) denote active-low signals.
DEMOACEX USER GUIDE APRIL 3, 2008
4
FEATURES
The DEMOACEX is a peripheral expansion board designed to interface with the DEMOAC
board. The DEMOACEX applies the Freescale MC33794 E-Field Imaging Sensor connected
to touch-pad in various arrangements. An 80-pin IO header allows the DEMOACEX to con-
nect directly to the DEMOAC board.
DEMOACEX Features:
80-pin MCU PORT connects to DEMOAC board
9ch, E-Field Sensor
E-Field Touch Pad including Rotary Dial and Push-
Buttons
2 Low-Pass RC Filters
5V – 12V Boost Switcher Power Supply for E-Field
Sensor
LEDs – 10 User, 1 E-Field Lamp
CAN 2.0 A/B PHY w/ 3-pos header
Jumpers to disconnect all IO signals
SOIC and TSSOP pads for external IC's
Large thru-hole prototyping area w/ +adjacent 5V
and GND
DEMOACEX Board Size: 6.0” x 4.5”MCU Modules:
DEMOACEX USER GUIDE APRIL 3, 2008
5
REFERENCES
The following documents should be referenced during application development using the
DEMOAC and DEMOACEX. These documents are available on the Axiom Manufacturing web
site at www.axman.com/support.
DEMOACEX_UG.pdf DEMOACEX User Guide (this document)
DEMOACEX_QSG.pdf DEMOACEX Quick Start Guide
DEMOACEX_SCH_A.pdf DEMOACEX Schematic
DEMOACEX_Silk_A.pdf DEMOACEX Top Silk
GETTING STARTED
To get started quickly, please refer to the DEMOACEX Quick Start Guide. This quick start will
illustrate connecting the board to a PC, installing the correct version of CodeWarrior Develop-
ment Studio, and running a simple program.
APPLICATION DEVELOPMENT
The DEMOACEX is designed for use with the DEMOAC board. Please refer to the DEMOAC
documentation for details on application development.
HARDWARE CONFIGURATION
The DEMOACEX applies the Freescale MC33794 E-Field sensor, 12 green LEDs, a CAN
PHY, and 2 RC filters. Inputs to the E-Field sensor are provided from touch-pads in various
configurations.
POWER
Power to the DEMOACEX is provided from IO header on pins J1-1 and J1-3. Pin J1-1 is con-
nected directly to the +5V rail on the DEMOACEX. Pin J1-3 is connected directly to the GND
rail. No protection is provided on this power input. When powering the board, other than
through the DEMOAC, care must be used to prevent overdriving this input.
E-FIELD SENSOR
The DEMOACEX applies the Freescale MC33794 E-Field Sensor and touch-pads in various
configurations. Refer to the MC33794 data sheet for details on using the device.
DEMOACEX USER GUIDE APRIL 3, 2008
6
Touch-pads configurations include a rotary dial with center button, 3 solid push buttons using a
single electrode input and 3 intertwined push buttons using 2 electrodes each. The rotary dial
is created using 3 touch-pads of non-uniform shape intertwined in a circular pattern. The solid
push-button touch-pads are created using a solid electrode placed over a solid shield. The
intertwined push buttons are created by interlacing 2 electrode inputs. Use of the intertwined
push buttons does not require activating the shield electrode.
Touch-pads are connected to the E-Field Sensor inputs as shown in the table below.
Table 1 : E-Field Sensor Input Configuration
Sensor Input E-Field Sensor
Electrode
Push-Buttons:
Button 1 E7
Button 2 E3
Button 3 E2
Button 4 E1
Button 5 E3 & E1
Button 6 E3 & E2
Button 7 E2 & E1
Rotary Dial:
Left Hand Lobe E6
Center Lobe E4
Right Hand Lobe E5
Three electrode selection inputs on the E-Field Sensor select the active electrode. The
Shield_EN input on the sensor enables or disables the e-field shield. These inputs are con-
nected to PTC signals on the DEMOAC board through the IO header.
A single level output from the sensor provides the detected analog level output to the
DEMOAC board through the IO header. This signal is available on AD1P11 on the DEMOAC.
A yellow LAMP LED indicates normal operation. This LED is normally on. When OFF this
LED indicates a fault condition. Refer to the MC337094 Datasheet for further details.
CAN PORT
The DEMOACEX applies the TJA1040 CAN PHY. The PHY is connected to the IO header
through the CAN_EN option header. Installing a shunt enables the associated signal. Re-
moving the shunt disables the associated signal.
DEMOACEX USER GUIDE APRIL 3, 2008
7
Figure 1: CAN_EN Option Header
CAN_EN ON OFF
STB Enabled Disabled
TX Enabled Disabled
RX Enabled Disabled
Differential CAN signal termination is applied. A 120 ohm termination resistor with option
jumper allows termination to be applied or removed. The CANT_EN option jumper applies or
removes the CAN termination.
User LED’s
Twelve user LED's are provided for output indication and are configured for active-low signal-
ing. The table below details the LED connections to the target MCU
Table 2: User LED’s
LED J1- DEMOAC Signal
LED5 13 PTE2/RGPIO2/FTM1CH0
LED6 15 PTE3/RGPIO3/FTM1CH1
LED7 23 PTE4/RGPIO4/SS1*
LED8 19 PTE5/RGPIO5/MISO1
LED9 17 PTE6/RGPIO6/MOSI1
LED10 21 PTE7/RGPIO7/SPSCK1
LED11 50 PTA2
LED12 52 PTA3/ACMP2O
LED13 54 PTA4/ACMP2-
LED14 56 PTA5/ACMP2+
LED15 58 PTA6/AD1P16
LED16 60 PTA7/AD1P17
NOTE: LED5 input signal also provides RC filter input
LED11 input signal also provides CAN PHY standby control
DEMOACEX USER GUIDE APRIL 3, 2008
8
IO HEADER
The IO Header provides access to on-board signals. The Figure below shows the pin-out of
the IO header
Figure 2: IO Header Connector
VDD 1 2
VSS 3 4
5 6
7 8
910
11 12
PTE2/RGPIO2/FTM1CH0 13 14
PTE3/RGPIO3/FTM1CH1 15 16
PTE6/RGPIO6/MOSI1 17 18
PTE5/RGPIO5/MISO1 19 20
PTE7/RGPIO7/SPSCK1 21 22
PTE4/RGPIO4/SS1* 23 24
25 26 PTA0/TXCAN
PTD3/KBI1P6/AD1P11 27 28 PTA1/RXCAN
29 30
31 32
33 34
35 36 PTC4/SS2*
PTF4/RGPIO12/FTM2CH0 37 38
39 40
41 42 PTC0/SCL1
43 44 PTC1/SDA1
45 46 PTC2/MCLK
47 48
49 50 PTA2
51 52 PTA3/ACMP2O
53 54 PTA4/ACMP2-
55 56 PTA5/ACMP2+
57 58 PTA6/AD1P16
59 60 PTA7/AD1P17
61 62
63 64
65 66
67 68
69 70
71 72
73 74
75 76
77 78
79 80
DEMOACEX USER GUIDE APRIL 3, 2008
9
TROUBLESHOOTING
The DEMOACEX is fully tested and operational before shipping. If it fails to function properly,
inspect the board for obvious physical damage first.
Most common problems are related to improperly configured options or communications pa-
rameters.
1. Verify default option jumper settings.
2. Verify the yellow LAMP LED is ON.
3. Verify the DEMOACEX is properly and securely attached to the DEMOAC board
4. Ensure the DEMOAC board is configured properly and that power is applied.
5. If possible, verify an approximately 120 kHz square wave output at E-Field sensor (U2-
24)
If the above Troubleshooting Tips fail to correct the problem, please contact Freescale Semi-
conductors for further assistance. Please refer to the Technical Information Card (TIC) in-
cluded in the kit. Users may also contact Axiom Manufacturing at support@axman.com for
additional support.