General Purpose Relays
Industrial Relays
KUIP/KUGP Series Panel Plug-in Relay
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
Potter & Brumfield
Coil versions, DC coil
Coil Rated Operate Coil Rated coil
code voltage voltage resistance power
VDC VDC Ω±10% W
KUIP
5 5 3.75 21 1.2
6 6 4.5 32.1 1.125
12 12 9.0 120 1.2
24 24 18.0 472 1.25
48 48 36.0 1800 1.3
110 110 82.5 10000 1.25
KUGP
5 5 3.75 14 1.8
6 6 4.5 20 1.8
12 12 9.0 80 1.8
24 24 18.0 320 1.8
48 48 36.0 1250 1.85
110 110 82.5 6720 1.8
All figures are given for coil without preenergization, at ambient temperature +23°C.
Coil versions, AC coil
Coil Rated Operate Coil Rated coil
code voltage voltage resistance power
VAC VAC Ω±15% VA
KUIP 1 and 2 pole
6 6 5.1 6 2.0
12 12 10.2 24 2.0
24 24 20.4 85 2.0
120 120 102.0 2250 2.1
240 240 204.0 9110 2.1
KUIP 3 pole, KUGP
6 6 5.1 4.2 2.8
12 12 10.2 18 2.8
24 24 20.4 72 2.8
120 120 102.0 1700 2.9
240 240 204.0 7200 2.9
All figures are given for coil without preenergization, at ambient temperature +23°C.
Insulation Data KUIP KUGP
Initial dielectric strength
between open contacts 1200Vrms 3500Vrms
between contact and coil 2200Vrms 3750Vrms
between adjacent contacts 2200Vrms 3750Vrms
Initial insulation resistance
between insulated elements 100MΩ, 500VDC
n 10 amp rated relays
n 2 Form A (NO) and 1-3 Form C (CO) contact arrangement
n KUIP 8mm coil-to-contact spacing and KUGP 3mm contact gap
n Various mounting and socket styles
Typical applications
Voltage control units
Approvals
UL E22575; CSA LR15734
Technical data of approved types on request
Contact Data
Contact arrangement
KUGP: 2 form A (NO); 3 form A (NO)
KUIP:
1 form C (CO), 2 form A (NO), 2 form C (CO), 3 form C (CO)
Rated voltage 240VAC
Rated current 10A
Contact material Ag AgCdO
Min recommended contact load 100mA, 12VDC 300mA, 12VDC
Frequency of operation 360 ops./hour 360 ops./hour
Operate/releases time max. 20/15ms
Bounce time max. 20ms
Contact ratings
Type Load Cycles
UL 508
Ag
5A, 240VAC
5A, 28VDC
1/6HP, 120VAC
2.5A, 120VAC, tungsten
1/3HP, 240VAC
0.5A, 120VDC
5FLA, 15LRA, 250VAC
AgCdO
10A, 240VAC
10A, 32VDC
5FLA, 15LRA, 250VAC
1/3HP, 120VAC
5A, 120VAC, tungsten
1/2HP, 250VAC
0.5A, 125VDC
10FLA, 40LRA, 125VAC
3A, 600VAC
1/2HP, 480VAC
1/2HP, 600VAC
1HP, 480VAC, 3 phase
Mechanical endurance 10x106 ops.
Coil Data
Coil voltage range 6 to 110VDC
6 to 240VAC
Coil insulation system according UL Class B