Benets
Approvals: ENEC, UL, cUL, CQC
Class X2 (IEC 60384-14)
Rated voltage: 275 VAC 50/60 Hz
Capacitance range: 0.01 – 10 µF
Lead spacing: 10.0 – 37.5 mm
Capacitance tolerance: ±20%, ±10%
Climatic category: 40/110/56, IEC 600681
Tape and reel in accordance with IEC 60286–2
RoHS Compliant and lead-free terminations
• Operatingtemperaturerangeof−40˚Cto+110˚C
100% screening factory test at 2,200 VDC/1,500 VAC
Self-healing properties
Overview
TheR46Seriesisconstructedofmetallizedpolypropylenelm
encapsulated with self-extinguishing resin in a box of material
meeting the requirements of UL 94 V–0.
Applications
For worldwide use in electromagnetic interference (EMI)
suppression in across-the-line applications requiring X2 safety
classication.Intendedforuseinsituationswherecapacitor
failure would not result in exposure to electric shock. Not for use
in "series with mains" type applications.
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Part Number System
R46 K I 2100 00 01 M
Series
Rated Voltage
(VAC)
Lead Spacing
(mm)
Capacitance Code
(pF)
Packaging Internal Use
Capacitance
Tolerance
X2, Metallized
Polypropylene
K = 275 F = 10.0
I = 15.0
N = 22.5
R = 27.5
W = 37.5
The last three digits
representsignicant
gures.Therst
digitspecies
number of zeros to
be added.
See Ordering
Options Table
01
02
L2
M1
M2
N0
N1
N2
K = ±10%
M = ±20%
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 2
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Ordering Options Table
Lead Spacing
Nominal (mm) Type of Leads and Packaging Lead Length
(mm)
Lead and
Packaging Code
10,
15,
22.5
Standard Lead and Packaging Options
Bulk (Bag) – Short Leads
4+2/-0
00
Ammo Pack
H0=18.5+/-0.5
DQ
Other Lead and Packaging Options
Tape & Reel (Large Reel) H
0
=18.5+/-0.5 CK
Bulk (Bag) – Short Leads 2.7+0.5/-0 JA
Bulk (Bag) – Short Leads 3.5+0.5/-0 JB
Bulk (Bag) – Short Leads 4.0+0.5/-0 JE
Bulk (Bag) – Short Leads 3.2+0.3/-0.2 JH
Bulk (Bag) – Long Leads 18+1/-1 JM
Bulk (Bag) – Long Leads 30+5/-0 40
Bulk (Bag) – Long Leads 25+2/-1 50
Bulk (Bag) – Insulated Rigid Leads 30+5/-0(sp8+2/-2) 51
Bulk (Bag) – Insulated Flexible Leads 150+5/-5(sp8+2/-2) 52
27.5
Standard Lead and Packaging Options
Bulk (Bag) – Short Leads
4+2/-0
00
Tape & Reel (Large Reel)
H0=18.5+/-0.5
CK
Other Lead and Packaging Options
Bulk (Bag) – Short Leads
2.7+0.5/-0
JA
Bulk (Bag) – Short Leads
3.5+0.5/-0
JB
Bulk (Bag) – Short Leads
4.0+0.5/-0
JE
Bulk (Bag) – Short Leads
3.2+0.3/-0.2
JH
Bulk (Bag) – Long Leads
18+1/-1
JM
Bulk (Bag) – Long Leads
30+5/-0
40
Bulk (Bag) – Long Leads
25+2/-1
50
Bulk (Bag) – Insulated Rigid Leads
30+5/-0(sp8+2/-2)
51
Bulk (Bag) – Insulated Flexible Leads
150+5/-5(sp8+2/-2)
52
37.5
Standard Lead and Packaging Options
Bulk (Bag) – Short Leads
4+2/-0
00
Other Lead and Packaging Options
Bulk (Bag) – Short Leads
2.7+0.5/-0
JA
Bulk (Bag) – Short Leads
3.5+0.5/-0
JB
Bulk (Bag) – Short Leads
4.0+0.5/-0
JE
Bulk (Bag) – Short Leads
3.2+0.3/-0.2
JH
Bulk (Bag) – Long Leads
18+1/-1
JM
Bulk (Bag) – Long Leads
30+5/-0
40
Bulk (Bag) – Long Leads
25+2/-1
50
Bulk (Bag) – Insulated Rigid Leads
30+5/-0(sp8+2/-2)
51
Bulk (Bag) – Insulated Flexible Leads
150+5/-5(sp8+2/-2)
52
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 3
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Dimensions – Millimeters
H
p
LL
d
L B
FRONT VIEW SIDE VIEW
L B
H
8 ±2
35 +0/-5
d
Loose Insulated Rigid Leads
FRONT VIEW SIDE VIEW
L B
H
8 ±2
150 ±5
d
Insulated Flexible Leads 0.5 mm
2
FRONT VIEW SIDE VIEW
p B H L d
Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance
10.0
4.0
+0.2
9.0
+0.1
13.0
+0.2
+/-0.05
10.0
5.0
+0.2
11.0
+0.1
13.0
+0.2
+/-0.05
10.0
6.0
+0.2
12.0
+0.1
13.0
+0.2
+/-0.05
15.0
5.0
+0.2
11.0
+0.1
18.0
+0.3
+/-0.05
15.0
6.0
+0.2
12.0
+0.1
18.0
+0.3
+/-0.05
15.0
6.0
+0.2
17.5
+0.1
18.0
+0.3
+/-0.05
15.0
7.5
+0.2
13.5
+0.1
18.0
+0.5
+/-0.05
15.0
7.5
+0.2
18.5
+0.1
18.0
+0.5
+/-0.05
15.0
8.5
+0.2
14.5
+0.1
18.0
+0.5
+/-0.05
15.0
9.0
+0.2
12.5
+0.1
18.0
+0.5
+/-0.05
15.0
10.0
+0.2
16.0
+0.1
18.0
+0.5
+/-0.05
15.0
11.0
+0.2
19.0
+0.1
18.0
+0.5
+/-0.05
15.0
13.0
+0.2
12.0
+0.1
18.0
+0.5
+/-0.05
22.5
6.0
+0.2
15.0
+0.1
26.5
+0.3
+/-0.05
22.5
7.0
+0.2
16.0
+0.1
26.5
+0.3
+/-0.05
22.5
10.0
+0.2
18.5
+0.1
26.5
+0.3
+/-0.05
22.5
11.0
+0.2
20.0
+0.1
26.5
+0.3
+/-0.05
27.5
9.0
+0.2
17.0
+0.1
32.0
+0.3
+/-0.05
27.5
11.0
+0.2
20.0
+0.1
32.0
+0.3
+/-0.05
27.5
13.0
+0.2
22.0
+0.1
32.0
+0.3
+/-0.05
27.5
13.0
+0.2
25.0
+0.1
32.0
+0.3
+/-0.05
27.5
14.0
+0.2
28.0
+0.1
32.0
+0.3
+/-0.05
27.5
18.0
+0.2
33.0
+0.1
32.0
+0.3
+/-0.05
27.5
22.0
+0.2
37.0
+0.1
32.0
+0.3
+/-0.05
Note: See Ordering Options Table for lead length (LL/H0) options.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 4
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Dimensions – Millimeters cont'd
H
p
LL
d
L B
FRONT VIEW SIDE VIEW
L B
H
8 ±2
35 +0/-5
d
Loose Insulated Rigid Leads
FRONT VIEW SIDE VIEW
L B
H
8 ±2
150 ±5
d
Insulated Flexible Leads 0.5 mm
2
FRONT VIEW SIDE VIEW
p B H L d
Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance Nominal Tolerance
37.5
11.0
+0.3
22.0
+0.1
41.5
+0.3
+/-0.05
37.5
13.0
+0.3
24.0
+0.1
41.5
+0.3
+/-0.05
37.5
16.0
+0.3
28.5
+0.1
41.5
+0.3
+/-0.05
37.5
19.0
+0.3
32.0
+0.1
41.5
+0.3
+/-0.05
37.5
20.0
+0.3
40.0
+0.1
41.5
+0.3
+/-0.05
37.5
24.0
+0.3
44.0
+0.1
41.5
+0.3
+/-0.05
37.5
30.0
+0.3
45.0
+0.1
41.5
+0.3
+/-0.05
Note: See Ordering Options Table for lead length (LL/H0) options.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 5
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Performance Characteristics
Dielectric Polypropylenelm
Plates Metal layer deposited by evaporation under vacuum
Winding Non-inductive type
Leads Tinned wire
Protection Plasticcase,thermosettingresinlled.BoxmaterialissolventresistantandameretardantaccordingtoUL94.
Related documents IEC 60384-14, EN 60384-14
Rated Voltage (VR) 275 VAC (50/60 Hz), 560 VDC
Capacitance Range 0.010 µF to 10 µF
Capacitance Values E6series(IEC60063)measured@1kHzand+20±1°C
Capacitance Tolerance ±10%, ±20%
Temperature Range 40ºCto+110°C
Climatic Category 40/110/56 IEC 60068-1
Storage Conditions
Storagetime:≤24monthsfromthedatemarkedonthelabelpackage
Averagerelativehumidityperyear≤70%
RH≤85%for30daysrandomlydistributedthroughouttheyear
Dew is absent
Temperature: −40to80°C(see"MaximumHumidityinStorageConditions"graphbelow)
Approvals ENEC, UL, cUL, CQC
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 6
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Performance Characteristics cont'd
* Typical value
Impedance Graph
DissipationFactor(tanδ) ≤0.1%(0.06%*)@1kHz,+25°C±5°C(*typicalvalue)
Test Voltage Between Terminals
The 100% screening factory test is carried out at 2,200 VDC/1,500 VAC. The voltage level is selected to meet the
requirements in applicable equipment standards. All electrical characteristics are checked after the test. It is not
permitted to repeat this test as there is a risk to damage the capacitor. KEMET is not liable in such case for any failures.
Insulation Resistance
Measuredat+25°C±5°C,accordingtoIEC60384–2
Minimum Values Between Terminals
Voltage Charge Voltage Charge Time C≤0.33μF C>0.33μF
100 VDC 1 minute
≥1•105MΩ
(≥5•10
5
MΩ)*
≥30,000MΩ•µF
(≥150,000MΩ•µF)*
In DC Applications Recommendedvoltage≤560VDC
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 7
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Environmental Test Data
Test
IEC Publication
Procedure
Endurance EN/IEC 60384–14
1.25 x V
R
VAC 50 Hz, once every hour increase to 1,000 VAC for 0.1
second, 1,000 hours at upper rated temperature
Vibration IEC 600682–6 Test Fc 3 directions at 2 hours each 10 – 55 Hz at 0.75 mm or 98 m/s2
Bump IEC 60068–2–29 Test Eb 1,000 bumps at 390 m/s2
Change of Temperature IEC 60068–2–14 Test Na Upper and lower rated temperature 5 cycles
Active Flammability IEC 60384–14 VR+20surgepulsesat2.5kV(pulseevery5seconds)
Passive Flammability IEC 60384–14 IEC60384–1,IEC60695–11–5Needleametest
Damp Heat Steady State IEC 60068–2–78 Test Cab +40°Cand93%RH,56days
Approvals
Mark
Specication
File Number
EN/IEC 60384-14 V4413
UL 60384-14 and
CAN/CSA E60384-14
(310VAC)
E97797
IEC 60384-14
CQC08001026549
CQC11001060118
CQC13001087757
CQC14001116028
CQC13001101266
CQC14001116000
Environmental Compliance
All KEMET EMI capacitors are RoHS Compliant.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 8
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Table 1 – Ratings & Part Number Reference
Capacitance
Value (µF)
Dimensions in mm Lead Spacing
(p)
dV/dt
(V/µs)
New KEMET
Part Number Legacy Part Number
B H L
0.010 4.0 9.0 13.0 10.0 500 46KF2100(1)N0(2) R46KF2100(1)N0(2)
0.015 4.0 9.0 13.0 10.0 500 46KF2150(1)N0(2) R46KF2150(1)N0(2)
0.022 4.0 9.0 13.0 10.0 500 46KF2220(1)N0(2) R46KF2220(1)N0(2)
0.033 5.0 11.0 13.0 10.0 500 46KF2330(1)M1(2) R46KF2330(1)M1(2)
0.047 5.0 11.0 13.0 10.0 500 46KF2470(1)N0(2) R46KF2470(1)N0(2)
0.068 6.0 12.0 13.0 10.0 500 46KF2680(1)M1(2) R46KF2680(1)M1(2)
0.10 6.0 12.0 13.0 10.0 500 46KF3100(1)M1(3) R46KF3100(1)M1(3)
0.010 5.0 11.0 18.0 15.0 400 46KI 2100(1)01(2) R46KI 2100(1)01(2)
0.015 5.0 11.0 18.0 15.0 400 46KI 2150(1)01(2) R46KI 2150(1)01(2)
0.022 5.0 11.0 18.0 15.0 400 46KI 2220(1)01(2) R46KI 2220(1)01(2)
0.033 5.0 11.0 18.0 15.0 400 46KI 2330(1)01(2) R46KI 2330(1)01(2)
0.047 5.0 11.0 18.0 15.0 400 46KI 2470(1)01(2) R46KI 2470(1)01(2)
0.068 5.0 11.0 18.0 15.0 400 46KI 2680(1)01(2) R46KI 2680(1)01(2)
0.10 5.0 11.0 18.0 15.0 400 46KI 3100(1)M1(2) R46KI 3100(1)M1(2)
0.15 6.0 12.0 18.0 15.0 400 46KI 3150(1)M2(2) R46KI 3150(1)M2(2)
0.15 9.0 12.5 18.0 15.0 400 46KI 3150(1)L2(2) R46KI 3150(1)L2(2)
0.22 7.5 13.5 18.0 15.0 400 46KI 3220(1)M2(2) R46KI 3220(1)M2(2)
0.22 9.0 12.5 18.0 15.0 400 46KI 3220(1)L2(2) R46KI 3220(1)L2(2)
0.22 6.0 17. 5 18.0 15.0 400 46KI 3220(1)02(2) R46KI 3220(1)02(2)
0.33 8.5 14.5 18.0 15.0 400 46KI 3330(1)N0(2) R46KI 3330(1)N0(2)
0.33 10.0 16.0 18.0 15.0 400 46KI 3330(1)M1(2) R46KI 3330(1)M1(2)
0.33 9.0 12.5 18.0 15.0 400 46KI 3330(1)N1(3) R46KI 3330(1)N1(3)
0.33 7.5 18.5 18.0 15.0 400 46KI 3330(1)02(2) R46KI 3330(1)02(2)
0.33 13.0 12.0 18.0 15.0 400 46KI 3330(1)01(2) R46KI 3330(1)01(2)
0.47 7.5 18.5 18.0 15.0 400 46KI 3470(1)02(3) R46KI 3470(1)02(3)
0.47 10.0 16.0 18.0 15.0 400 46KI 3470(1)N0(3) R46KI 3470(1)N0(3)
0.47 11.0 19.0 18.0 15.0 400 46KI 3470(1)M1(2) R46KI 3470(1)M1(2)
0.56 11.0 19.0 18.0 15.0 400 46KI 3560(1)N0(2) R46KI 3560(1)N0(2)
0.60 11.0 19.0 18.0 15.0 400 46KI 3600(1)N0(2) R46KI 3600(1)N0(2)
0.15 6.0 15.0 26.5 22.5 200 46KN3150(1)01(2) R46KN3150(1)01(2)
0.22 6.0 15.0 26.5 22.5 200 46KN3220(1)M1(2) R46KN3220(1)M1(2)
0.33 6.0 15.0 26.5 22.5 200 46KN3330(1)N0(2) R46KN3330(1)N0(2)
0.47 7.0 16.0 26.5 22.5 200 46KN3470(1)N0(2) R46KN3470(1)N0(2)
0.68 10.0 18.5 26.5 22.5 200 46KN3680(1)M2(2) R46KN3680(1)M2(2)
1.00 10.0 18.5 26.5 22.5 200 46KN4100(1)N2(3) R46KN4100(1)N2(3)
1.00 11.0 20.0 26.5 22.5 200 46KN4100(1)N1(2) R46KN4100(1)N1(2)
0.47 9.0 17.0 32.0 27.5 150 46KR3470(1)01(2) R46KR3470(1)01(2)
0.68 9.0 17.0 32.0 27.5 150 46KR3680(1)M1(2) R46KR3680(1)M1(2)
1.0 11.0 20.0 32.0 27.5 150 46KR4100(1)M1(2) R46KR4100(1)M1(2)
1.5 13.0 22.0 32.0 27.5 150 46KR4150(1)M1(2) R46KR4150(1)M1(2)
2.2 13.0 25.0 32.0 27. 5 150 46KR4220(1)M2(2) R46KR4220(1)M2(2)
2.2 14.0 28.0 32.0 27.5 150 46KR4220(1)M1(2) R46KR4220(1)M1(2)
3.3 18.0 33.0 32.0 27. 5 150 46KR4330(1)M2(2) R46KR4330(1)M2(2)
4.7 18.0 33.0 32.0 27.5 150 46KR4470(1)M2(2) R46KR4470(1)M2(2)
4.7 22.0 37.0 32.0 27.5 150 46KR4470(1)M1(2) R46KR4470(1)M1(2)
1.5 11.0 22.0 41.5 37.5 100 46KW4150(1)M1(2) R46KW4150(1)M1(2)
2.2 11.0 22.0 41.5 37.5 100 46KW4220(1)M2(3) R46KW4220(1)M2(3)
2.2 13.0 24.0 41.5 37.5 100 46KW4220(1)M1(2) R46KW4220(1)M1(2)
3.3 16.0 28.5 41.5 37.5 100 46KW4330(1)M1(2) R46KW4330(1)M1(2)
4.7 16.0 28.5 41.5 37.5 100 46KW4470(1)M2(3) R46KW4470(1)M2(3)
4.7 19.0 32.0 41.5 37.5 100 46KW4470(1)M1(2) R46KW4470(1)M1(2)
6.8 20.0 40.0 41.5 37.5 100 46KW4680(1)M2(2) R46KW4680(1)M2(2)
6.8 24.0 44.0 41.5 37. 5 100 46KW4680(1)M1(2) R46KW4680(1)M1(2)
10.0 30.0 45.0 41.5 37. 5 100 46KW5100(1)M1(2) R46KW5100(1)M1(2)
Capacitance Value (µF) B (mm) H (mm) L (mm) Lead
Spacing (p) dV/dt (V/µs) New KEMET
Part Number Legacy Part Number
(1) Insert lead and packaging code. See Ordering Options Table for available options.
(2) M = ±20%, K = ±10%
(3) M = ±20% (only available tolerance).
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 9
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Manual Soldering Recommendations
Following is the recommendation for manual
soldering with a soldering iron.
The soldering iron tip temperature should be set
at350°C(+10°Cmaximum)withthesoldering
duration not to exceed more than 3 seconds.
Recommended Soldering Temperature
0
50
100
150
200
250
300
350
400
012345678
Soldering time (sec)
Soldering iron bit temperature (deg C)
Soldering Process
The implementation of the RoHS directive has resulted in the selection of SnAgCu (SAC) alloys or SnCu alloys as primary solder. This has
increased the liquidus temperature from that of 183ºC for SnPb eutectic alloy to 217 – 221ºC for the new alloys. As a result, the heat stress
to the components, even in wave soldering, has increased considerably due to higher pre-heat and wave temperatures. Polypropylene
capacitors are especially sensitive to heat (the melting point of polypropylene is 160 – 170ºC). Wave soldering can be destructive, especially
for mechanically small polypropylene capacitors (with lead spacing of 5 mm to 15 mm), and great care has to be taken during soldering. The
recommendedsolderprolesfromKEMETshouldbeused.PleaseconsultKEMETwithanyquestions.Ingeneral,thewavesolderingcurve
from IEC Publication 61760-1 Edition 2 serves as a solid guideline for successful soldering. Please see Figure 1.
Reowsolderingisnotrecommendedforthrough-holelmcapacitors.Exposingcapacitorstoasolderingproleinexcessoftheabovethe
recommended limits may result to degradation or permanent damage to the capacitors.
Do not place the polypropylene capacitor through an adhesive curing oven to cure resin for surface mount components. Insert through-
holepartsafterthecuringofsurfacemountparts.ConsultKEMETtodiscusstheactualtemperatureproleintheoven,ifthrough-hole
components must pass through the adhesive curing process. A maximum two soldering cycles is recommended. Please allow time for the
capacitor surface temperature to return to a normal temperature before the second soldering cycle.
Wave Soldering Recommendations
0
50
100
150
200
250
300
0
40
80
120
160
200
240
Temperature (°C)
Time (s)
ca 2°C/s
ca 3.5°C/s typical
ca 5°C/s
Cooling
2+3s max
115°C max
T
preh eat
ΔT <150°C
100°C
Preheating
Typical
First wave
Second wave
260°C
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 10
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Soldering Process cont'd
Wave Soldering Recommendations cont'd
1. The table indicates the maximum set-up temperature of the soldering process
Figure 1
Dielectric
Film Material
Maximum Preheat
Temperature
Maximum
Peak Soldering
Temperature
Capacitor
Pitch
≤10mm
Capacitor
Pitch
= 15 mm
Capacitor
Pitch
> 15 mm
Capacitor
Pitch
≤15mm
Capacitor
Pitch
> 15 mm
Polyester 130°C 130°C 130°C 270°C 270°C
Polypropylene 10C 110°C 130°C 260°C 270°C
Paper 130°C 130°C 140°C 270°C 270°C
Polyphenylene
Sulphide 150°C 150°C 160°C 270°C 270°C
2. The maximum temperature measured inside the capacitor:
Set the temperature so that inside the element the maximum temperature is below the limit:
Dielectric Film Material Maximum temperature
measured inside the element
Polyester 160°C
Polypropylene 110°C
Paper 160°C
Polyphenylene
sulphide
16C
Temperature monitored inside the capacitor.
Selective Soldering Recommendations
Selectivedipsolderingisavariationofreowsoldering.Inthismethod,theprintedcircuitboardwiththrough-holecomponentstobe
solderedispreheatedandtransportedoverthesolderbathasinnormalowsolderingwithouttouchingthesolder.Whentheboardis
over the bath, it is stopped and pre-designed solder pots are lifted from the bath with molten solder only at the places of the selected
components, and pressed against the lower surface of the board to solder the components.
Thetemperatureproleforselectivesolderingissimilartothedoublewaveowsolderingoutlinedinthisdocument,however, instead
of two baths, there is only one bath with a time from 3 to 10 seconds. In selective soldering, the risk of overheating is greater than
indoublewaveowsoldering,andgreatcaremustbetakensothatthepartsarenotoverheated.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 11
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Construction
Detailed Cross Section
Self-Extinguishing
Resin
Molded Plastic
Case
Molded Plastic
Case
Leads
Metal Contact
Layer
Metal Contact
Layer
Margin
Single-sided Metallized
Polypropylene Film
(Second Layer)
Single-sided Metallized
Polypropylene Film
(First Layer)
Margin
Margin
Single-sided
Metallized
Polypropylene
Film
FILM WINDING SCHEME OPTIONS
1 Section
Single-sided
Metallized
Polypropylene
Film
Single-sided
Metallized
Polypropylene
Film
Single-sided
Metallized
Polypropylene
Film
Single-sided Metallized Polypropylene Film
2 Sections
3 Sections 4 Sections
Single-sided
Metallized
Polypropylene
Film
Polypropylene
Film Dielectric
1 Section
Double-sided Metallized Polyester Film
3 Sections
Double-sided
Metallized
Polyester Carrier
Film
Polypropylene
Film Dielectric
Double-sided
Metallized
Polyester Carrier
Film
2 Sections
Polypropylene
Film Dielectric
Double-sided
Metallized
Polyester Carrier
Film
Single-sided
Metallized
Polypropylene
Film
4 Sections
Polypropylene
Film Dielectric
Double-sided
Metallized
Polyester Carrier
Film
Polypropylene
Film Dielectric
1 Section
Polypropylene Film/Foil
2 Sections
Metal Foil Metal Foil
Single-sided
Metallized
Polypropylene
Film
Polypropylene
Film Dielectric
Metallized Polyphenylene
Sulfide Film with
Vacuum-Evaporated
Aluminum Electrodes
1 Section
Metallized Polyphenylene
Sulfide Film (SMR)
Metallized
Impregnated
Paper
1 Section
Metallized Impregnated Paper
Single-sided
Metallized
Polyester
Film
1 Section
Single-sided Metallized Polyester Film
Polypropylene
Film Dielectric
1 Section
AXIAL - Polypropylene Film/Foil
2 Sections
Metal Foil
Single-sided
Metallized
Polypropylene
Film
Polypropylene
Film Dielectric
Metal Foil
Single-sided
Metallized
Polypropylene
Film
2 Sections
Polypropylene
Film Dielectric
Double-sided
Metallized
Polyester Carrier
Film
Single-sided
Metallized
Polypropylene
Film
1 Section
AXIAL - Single-sided Metallized
Polypropylene Film
Single-sided
Metallized
Polyester
Film
1 Section
AXIAL - Single-sided Metallized
Polyester Film AXIAL - Double-sided
Metallized Polyester Film
Winding Scheme
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 12
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Marking
IEC Climatic
Category
Approval
Marks
TOPFRONT
Lead Spacing 10 mm
Manufacturer’s
Logo
Manufacturing
Plant
IEC Climatic
Category
Approval
Marks
TOPFRONT
Series
Capacitance,
Capacitance
Tolerance,
Rated Voltage
Manufacturing
Plant
Lead Spacing 22.5 mm (large case sizes), 27.5 mm, 37.5 mm
Manufacturers
Logo
Dielectric
Code
Safety
Class
Self
Healing
Passive
Flammability
Category
Date Code
QA Number
Capacitance Tolerance
Date Code
Capacitance,
Rated Voltage
Series,
Dielectric Code,
Safety Class,
Self Healing
IEC Climatic
Category
Approval
Marks
TOPFRONT
Lead Spacing 15 mm, 22.5 mm (small case sizes)
Manufacturer’s
Logo
Passive Flammability
Category
Manufacturing
Plant
Capacitance Tolerance
Date Code
Capacitance,
Rated Voltage
Series,
Dielectric Code,
Safety Class,
Self Healing
Passive Flammability Category:
B for volume ≥ 1750 mm
3
C for volume < 1750 mm
3
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 13
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Marking cont'd
IEC Climatic
Category
Approval
Marks
TOPFRONT
Lead Spacing 10 mm
Manufacturers
Logo
Manufacturing
Plant
IEC Climatic
Category
Approval
Marks
TOPFRONT
Series
Capacitance,
Capacitance
Tolerance,
Rated Voltage
Manufacturing
Plant
Lead Spacing 22.5 mm (large case sizes), 27.5 mm, 37.5 mm
Manufacturer’s
Logo
Dielectric
Code
Safety
Class
Self
Healing
Passive
Flammability
Category
Date Code
QA Number
Capacitance Tolerance
Date Code
Capacitance,
Rated Voltage
Series,
Dielectric Code,
Safety Class,
Self Healing
IEC Climatic
Category
Approval
Marks
TOPFRONT
Lead Spacing 15 mm, 22.5 mm (small case sizes)
Manufacturers
Logo
Passive Flammability
Category
Manufacturing
Plant
Capacitance Tolerance
Date Code
Capacitance,
Rated Voltage
Series,
Dielectric Code,
Safety Class,
Self Healing
Passive Flammability Category:
B for volume 1750 mm
3
C for volume < 1750 mm
3
Manufacturing Date Code (IEC 60062)
Y = Year, Z = Month
Year
Code
Month
Code
2000
M
January
1
2001
N
February
2
2002
P
March
3
2003
R
April
4
2004
S
May
5
2005
T
June
6
2006
U
July
7
2007
V
August
8
2008
W
September
9
2009
X
October
O
2010
A
November
N
2011
B
December
D
2012
C
2013
D
2014
E
2015
F
2016
H
2017
J
2018
K
2019
L
2020
M
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 14
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Packaging Quantities
Lead Spacing
(mm)
Thickness
(mm)
Height
(mm)
Length
(mm)
Bulk
Short Leads
Bulk
Long Leads
Standard
Reel
ø 355 mm
Large Reel
ø 500 mm
Ammo
Taped
10
4
9
13
2000
1800
750
1500
1000
5
11
13
1300
1500
600
1250
800
6
12
13
1000
1200
500
1000
680
15
5
11
18
2000
1000
600
1250
800
6
12
18
1750
900
500
1000
680
6
17.5
18
1000
700
500
1000
680
7.5
13.5
18
1000
700
350
800
500
7.5
18.5
18
900
500
800
500
8.5
14.5
18
1000
500
300
700
440
9
12.5
18
1000
520
270
650
410
10
16
18
750
500
300
600
380
11
19
18
450
350
500
340
13
12
18
750
490
200
480
280
22.5
6
15
26.5
805
500
700
464
7
16
26.5
700
500
550
380
10
18.5
26.5
396
300
350
235
11
20
26.5
360
250
350
217
27.5
9
17
32
816
408
450
11
20
32
560
336
350
13
22
32
480
288
300
13
25
32
480
288
14
28
32
352
176
18
33
32
256
128
22
37
32
168
112
37.5
11
22
41.5
420
252
13
24
41.5
360
216
16
28.5
41.5
216
108
19
32
41.5
192
96
20
40
41.5
126
84
24
44
41.5
108
72
30
45
41.5
90
60
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 15
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Lead Taping & Packaging (IEC 60286–2)
Taping Speci cation
Description Symbol
Dimensions (mm)
Lead Space
Tol.
10
15
22.5
27.5
Fig. 1
Fig. 2
Fig. 3
Fig. 3
Lead wire diameter
d
0.6
0.6-0.8
0.8
0.8
±0.05
Taping lead space P25.4 25.4 38.1 38.1 ±1
Feedholeleadspace* P
0
12.7 12.7 12.7 12.7 ±0.2**
Centering of the lead wire P
1
7.7 5.2 7.8 5.3 ±0.7
Centering of the body P
2
12.7 12.7 19.05 19.05 ±1.3
Leadspacing(pitch)*** F10 15 22.5 27.5 +0.6/-0.1
Component alignment ∆h 0000±2
Height of component
from tape center H0**** 18.5 18.5 18.5 18.5 ±0.5
Carrier tape width W18 18 18 18 +1/-0.5
Hold down tape width W
0
910 10 10 Minimum
Hole position W
1
9999±0.5
Hold down tape position W
2
3333Maximum
Feed hole diameter D
0
4 4 4 4 ±0.2
Tape thickness t0.7 0.7 0.7 0.7 ±0.2
* Also available in 15 mm.
** Max 1 mm on 20 lead spaces.
*** Pitches 15 mm and 10 mm taped to 7.5 mm (crimped leads) available upon request.
**** H0 = 16.5 mm available upon request.
P
P2
P0
F
H0
W
h
P1D0
W2
W1
W0
h
ød
t
P
P2
P1
Figure 1
Lead Spacing 10 mm
Figure 2
Lead Spacing 15 mm
Figure 3
Lead Spacing 22.5 – 27.5 mm
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 16
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Lead Taping & Packaging (IEC 60286–2) cont'd
Ammo Speci cations
Dimensions (mm)
H
W
T
360 340 59
Reel Speci cations
Reel Size
Dimensions (mm)
D H W
Standard
355
30
55 Maximum
Large
500
25
D
W
H
H
T
W
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 17
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
KEMET Corporation
World Headquarters
2835 KEMET Way
Simpsonville, SC 29681
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Corporate Of ces
Fort Lauderdale, FL
Tel: 954-766-2800
North America
Northeast
Wilmington, MA
Tel: 978-658-1663
Southeast
Lake Mary, FL
Tel: 407-855-8886
Central
Novi, MI
Tel: 248-994-1030
Irving, TX
Tel: 972-915-6041
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Europe
Southern Europe
Sasso Marconi, Italy
Tel: 39-051-939111
Skopje, Macedonia
Tel: 389-2-55-14-623
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Kamen, Germany
Tel: 49-2307-438110
Northern Europe
Wyboston, United Kingdom
Tel: 44-1480-273082
Espoo, Finland
Tel: 358-9-5406-5000
Asia
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Shenzhen, China
Tel: 86-755-2518-1306
Beijing, China
Tel: 86-10-5877-1075
Shanghai, China
Tel: 86-21-6447-0707
Seoul, South Korea
Tel: 82-2-6294-0550
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6701-8033
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com F3093_R46_X2_275_110C • 6/9/2016 18
Metallized Polypropylene Film EMI Suppression Capacitors
R46 Series, Class X2, 275 VAC, 110ºC
Disclaimer
Allproductspecications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecicallydisclaims–anywarrantyconcerningsuitabilityforaspeciccustomerapplicationoruse.TheInformationisintendedforuseonly
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all productrelated warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.