TECHNICAL INFORMATION
RATED PRIMARY VOLTAGE (V)
This is the supply voltage assigned to the transformer by the manufacturer.
RATED SECONDARY VOLTAGE (V)
This is the secondary output voltage assigned to the transformer when supplied with the rated primary voltage, frequency range, rated secondary
current, all assigned by the manufacturer for the specified operating conditions of the transformer.
RATED POWER (VA)
The specified power levels in this catalogue are the secondary power levels, in other words, those available when the transformer is loaded. It is the
product of the RMS rated secondary voltage by the RMS rated current. If the transformer has more than one output winding, the rated power
denotes the maximum sum of the products of RMS rated secondary voltage by the RMS rated secondary current, respectively. This rated power is
defined for rated ambient temperature conditions.
example : P = 3,2 VA ta 70/B
The transformer can deliver 3.2VA at maximum ambient (70°C), the load consisting of a resistor load defined by R(load) = U(sec)2/P (assigned U sec &
P values), heating does not exceed the relevant limit for Class B components used in this construction.
NOTE : When the transformer is intended to supply DC voltage and current in conjunction with rectifiers and smoothing capacitors, the VA power
required from the transformer is far higher than the U(DC) and I(DC) product. To help you to determine the true transformer power, our Technical
Department is at your disposal.
AMBIENT TEMPERATURE (ta)
The maximum temperature at which the transformer may be operated continuously under nominal conditions of use. It is the air temperature measu-
red close to the transformer after thermal stabilization when operating at rated conditions.
HEATING
The increase of the winding temperature when operating at rated conditions and maximum ambient temperature. The heating must be determined by
the resistance method.
TEMPERATURE CLASS
The international classification of temperature classes is as follows :
It defines the maximum temperature the transformer components must withstand in continuous operation, in compliance with the 85 IEC publica-
tion classification. There insulating materials are therefore certificated for the thermal index corresponding to the declared class in accordance with
216 IEC standard.
PARTICULAR POINTS OF EN 61558-2-6 STANDARD FOR SAFETY TRANSFORMERS
On-load secondary voltage tolerance.
This should not differ from the rated value by more than :
10% for transformers with build-in resistance to short-circuits (a supplement of 5% is granted on the 2 nd secondary for tranformers with 2
secondaries).
5% for other transformers whatever the secondaries number.
Off-load secondary voltage.
The values given in this catalogue are maximum theoretical values.
NOTE : For safety transformers, this should never exceed 50 V rms. In the case of a transformer with several secondaries, the sum of the
secondary voltages should be less tan 50 V rms.
ADAPTED TRANSFORMERS FROM THE STANDARDS SERIES
Any transformer whose requires Power and Ambient corresponding to those of our 44000 & 45000 range, and whose secondary voltage can fit in our
minimum to maximum secondary range will be covered by EN61558-2-6,EN60950, or UL506 approvals, depending on the effective choice .
SPECIAL TRANFORMERS
MYRRA can use the 44000, 45000 or 46000 standard ranges to examine any transformer for compliance with your specifications and with internatio-
nal standards.
On request, we can add thermal protection, thermal fuse, thermal switch-CTP.
In certain cases, the addition of thermal protection enables the ambient temperature to be increased, while still complying with EN 61558.
A 105°C H 180 °C
E 120°C 200 200 °C
B 130°C 220 220 °C
F 155°C 250 250 °C
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
117 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
5
0,6 VA EI 30-5 SERIE 44000
Rating
VA
Ambient
Temperature
°C
No-load
voltage
V
Secondary
current
m A
Secondary
voltage
V
Reference
Protection
Protection
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
40 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
EN 61558-2-6 EN 60950 UL 1585
QUALITY IN SERIES
79
51
67 910
51
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
Recommended layout for transformers
with 1 secondary winding
*To be noted : * marked transformers are non approved.
Those transformers meet all requirement of EN 61558-2-4.
44025 6 100 9,94 T 70 B 0,6
44026 9 66 14,95 T 70 B 0,6
44027 12 50 19,9 T 70 B 0,6
44028 15 40 24,9 T 70 B 0,6
44029 18 33 29,9 T 70 B 0,6
44030 24 25 39,8 T 70 B 0,6
44031 2 x 6 2 x 50 2 x 9,94 T 70 B 0,6
44032 2 x 9 2 x 33 2 x 14,95 T 70 B 0,6
44033 2 x 12 2 x 25 2 x 19,9 T 70 B 0,6
44034 2 x 15 2 x 20 2 x 24,9 T 70 B 0,6
44035 2 x 18 2 x 17 2 x 29,9 T 70 B 0,6
44036 2 x 24 2 x 12 2 x 39,8 T 70 B 0,6
44013 6 100 9,94 T 70 B 0,6
44014 9 66 14,95 T 70 B 0,6
44015 12 50 19,9 T 70 B 0,6
44016 15 40 24,9 T 70 B 0,6
44017 18 33 29,9 T 70 B 0,6
44018 24 25 39,8 T 70 B 0,6
44019 2 x 6 2 x 50 2 x 9,94 T 70 B 0,6
44020 2 x 9 2 x 33 2 x 14,95 T 70 B 0,6
44021 2 x 12 2 x 25 2 x 19,9 T 70 B 0,6
44022* 2 x 15 2 x 20 2 x 24,9 T 70 B 0,6
44023* 2 x 18 2 x 17 2 x 29,9 T 70 B 0,6
44024* 2 x 24 2 x 12 2 x 39,8 T 70 B 0,6
PRIMARY VOLTAGE
117 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
6
1-1,8 VA EI 30-10,5 SERIE 44000
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
67 910
51
No-load
voltage
V
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
70 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
44061 6 167 8,6 T 70 B 1
44062 9 111 12,9 T 70 B 1
44063 12 83 17,2 T 70 B 1
44064 15 67 21,6 T 70 B 1
44065 18 56 25,9 T 70 B 1
44066 24 42 37,9 T 70 B 1
44067 2 X 6 2 x 83 2 x 8,6 T 70 B 1
44068 2 x 9 2 x 56 2 x 12,9 T 70 B 1
44069 2 x 12 2 x 42 2 x 19 T 70 B 1
44070 2 x 15 2 x 33 2 x 23,6 T 70 B 1
44071 2 x 18 2 x 28 2 x 24,9 T 70 B 1
44072 2 x 24 2 x 21 2 x 37,9 T 70 B 1
44338 6 250 10,1 ta 70/B 1,5
44339 9 167 15,3 ta 70/B 1,5
44340 12 125 20,2 ta 70/B 1,5
44341 15 100 25,3 ta 70/B 1,5
44342 18 83 31,2 ta 70/B 1,5
44343 24 63 43,3 ta 70/B 1,5
44344 2 x 6 125 2 x 10,1 ta 70/B 1,5
44345 2 x 9 83 2 x 15,3 ta 70/B 1,5
44346 2 x 12 63 2 x 20,2 ta 70/B 1,5
44347 2 x 15 50 2 x 25,0 ta 70/B 1,5
44348* 2 x 18 42 2 x 31 ta 70/B 1,5
44349* 2 x 24 31 2 x 43 ta 70/B 1,5
44840 6 300 10,1 ta 70/B 1,8
44841 9 200 15,2 ta 70/B 1,8
44842 12 150 20,3 ta 70/B 1,8
44843 15 120 27,3 ta 70/B 1,8
44844 18 100 30,4 ta 70/B 1,8
44845 24 75 40,6 ta 70/B 1,8
44846 2 x 6 2 x 150 2 x 10,1 ta 70/B 1,8
44847 2 x 9 2 x 100 2 x 15,2 ta 70/B 1,8
44848 2 x 12 2 x 75 2 x 20,3 ta 70/B 1,8
44849 2 x 15 2 x 60 2 x 27,3 ta 70/B 1,8
PRIMARY VOLTAGE
230 V
44000 SERIES
ENCAPSULATED TRANSFORMERS
7
1-1,8 VA EI 30-10,5 SERIE 44000
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
Reference
No-load
voltage
V
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted 2 x 15 V and 2 x 24 V models are non-appro-
ved.
Those transformers meet all requirement of EN 61558-2-4
440496 167 8,6 T 70 B 1
440509 111 12,9 T 70 B 1
4405112 83 17,2 T 70 B 1
4405215 67 21,6 T 70 B 1
4405318 56 25,9 T 70 B 1
4405424 42 37,9 T 70 B 1
440552 x 6 2 x 83 2 x 8,6 T 70 B 1
440562 x 9 2 x 56 2 x 12,9 T 70 B 1
440572 x 12 2 x 42 2 x 19 T 70 B 1
440582 x 15 2 x 33 2 x 23,6 T 70 B 1
440592 x 18 2 x 28 2 x 24,9 T 70 B 1
44060*2 x 24 2 x 21 2 x 37,9 T 70 B 1
44326 6 250 10,1 ta 70/B 1,5
44327 9 167 15,3 ta 70/B 1,5
44328 12 125 20,2 ta 70/B 1,5
44329 15 100 25,3 ta 70/B 1,5
44330 18 83 31,2 ta 70/B 1,5
44331 24 63 43,3 ta 70/B 1,5
44332 2 x 6 125 2 x 10,1 ta 70/B 1,5
44333 2 x 9 83 2 x 15,3 ta 70/B 1,5
44334 2 x 12 63 2 x 20,2 ta 70/B 1,5
44335 2 x 15 50 2 x 25,0 ta 70/B 1,5
44336* 2 x 18 42 2 x 31 ta 70/B 1,5
44337* 2 x 24 31 2 x 43 ta 70/B 1,5
44830 6 300 10,1 ta 70/B 1,8
44831 9 200 15,2 ta 70/B 1,8
44832 12 150 20,3 ta 70/B 1,8
44833 15 120 27,3 ta 70/B 1,8
44834 18 100 30,4 ta 70/B 1,8
44835 24 75 40,6 ta 70/B 1,8
44836 2 x 6 2 x 150 2 x 10,1 ta 70/B 1,8
44837 2 x 9 2 x 100 2 x 15,2 ta 70/B 1,8
44838 2 x 12 2 x 75 2 x 20,3 ta 70/B 1,8
44839* 2 x 15 2 x 60 2 x 27,3 ta 70/B 1,8
PRIMARY VOLTAGE
117 V
1,5-1,8 VA EI 30-12,5
SERIE 44000
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
80 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V model is VDE EN 61558-2-6 certified
(production on request)
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
QUALITY IN SERIES
44000 SERIES
ENCAPSULATED TRANSFORMERS
8
44097 6 250 9,7 T 70 B 1,5
44098 9 167 14,5 T 70 B 1,5
44099 12 125 19,3 T 70 B 1,5
44100 15 100 24,2 T 70 B 1,5
44101 18 83 29,8 T 70 B 1,5
44102 24 63 38,6 T 70 B 1,5
44103 2 X 6 2 x 125 2 x 9,7 T 70 B 1,5
44104 2 x 9 2 x 83 2 x 15 T 70 B 1,5
44105 2 x 12 2 x 63 2 x 19,3 T 70 B 1,5
44106 2 x 15 2 x 50 2 x 24,2 T 70 B 1,5
44107 2 x 18 2 x 42 2 x 29 T 70 B 1,5
44108 2 x 24 2 x 31 2 x 38,6 T 70 B 1,5
44726 6 283 9,8 T 50 B 1,7
44727 9 189 14,8 T 50 B 1,7
44728 12 142 19,7 T 50 B 1,7
44729 15 113 24,6 T 50 B 1,7
44730 18 94 30,3 T 50 B 1,7
44731 24 71 39,3 T 50 B 1,7
44732 2 x 6 2 x 142 2 x 9,8 T 50 B 1,7
44733 2 x 9 2 x 94 2 x 15,2 T 50 B 1,7
44734 2 x 12 2 x 71 2 x 19,7 T 50 B 1,7
44735 2 x 15 2 x 57 2 x 24,6 T 50 B 1,7
44736 2 x 18 2 x 47 2 x 29,5 T 50 B 1,7
44737 2 x 24 2 x 35 2 x 39,3 T 50 B 1,7
44738 6 300 9,8 T 40 B 1,8
44739 9 200 14,8 T 40 B 1,8
44740 12 150 19,7 T 40 B 1,8
44741 15 120 24,6 T 40 B 1,8
44742 18 100 30,3 T 40 B 1,8
44743 24 75 39,3 T 40 B 1,8
44744 2 x 6 2 x 150 2 x 9,8 T 40 B 1,8
44745 2 x 9 2 x 100 2 x 15,2 T 40 B 1,8
44746 2 x 12 2 x 75 2 x 19,7 T 40 B 1,8
44747 2 x 15 2 x 60 2 x 24,6 T 40 B 1,8
44748 2 x 18 2 x 50 2 x 29,5 T 40 B 1,8
44749 2 x 24 2 x 38 2 x 39,3 T 40 B 1,8
PRIMARY VOLTAGE
230 V
1,5-1,8 VA EI 30-12,5
SERIE 44000
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are non-
approved.
Those transformers meet all requirement of EN 61558-2-4
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585
44000 SERIES
ENCAPSULATED TRANSFORMERS
9
440856 250 9,7 T 70 B 1,5
440869 167 14,5 T 70 B 1,5
4408712 125 19,3 T 70 B 1,5
4408815 100 24,2 T 70 B 1,5
4408918 83 29,8 T 70 B 1,5
4409024 63 38,6 T 70 B 1,5
440912 X 6 2 x 125 2 x 9,7 T 70 B 1,5
440922 x 9 2 x 83 2 x 15 T 70 B 1,5
440932 x 12 2 x 63 2 x 19,3 T 70 B 1,5
440942 x 15 2 x 50 2 x 24,2 T 70 B 1,5
44095*2 x 18 2 x 42 2 x 29 T 70 B 1,5
44096*2 x 24 2 x 31 2 x 38,6 T 70 B 1,5
44647 6 283 9,8 T 50 B 1,7
44648 9 189 14,8 T 50 B 1,7
44649 12 142 19,7 T 50 B 1,7
44650 15 113 24,6 T 50 B 1,7
44651 18 94 30,3 T 50 B 1,7
44652 24 71 39,3 T 50 B 1,7
44653 2 x 6 2 x 142 2 x 9,8 T 50 B 1,7
44654 2 x 9 2 x 94 2 x 15,2 T 50 B 1,7
44655 2 x 12 2 x 71 2 x 19,7 T 50 B 1,7
44656 2 x 15 2 x 57 2 x 24,6 T 50 B 1,7
44483* 2 x 18 2 x 47 2 x 29,5 T 50 B 1,7
44484* 2 x 24 2 x 35 2 x 39,3 T 50 B 1,7
44657 6 300 9,8 T 40 B 1,8
44658 9 200 14,8 T 40 B 1,8
44659 12 150 19,7 T 40 B 1,8
44660 15 120 24,6 T 40 B 1,8
44661 18 100 30,3 T 40 B 1,8
44662 24 75 39,3 T 40 B 1,8
44663 2 x 6 2 x 150 2 x 9,8 T 40 B 1,8
44664 2 x 9 2 x 100 2 x 15,2 T 40 B 1,8
44665 2 x 12 2 x 75 2 x 19,7 T 40 B 1,8
44666 2 x 15 2 x 60 2 x 24,6 T 40 B 1,8
44485* 2 x 18 2 x 50 2 x 29,5 T 40 B 1,8
44486* 2 x 24 2 x 38 2 x 39,3 T 40 B 1,8
PRIMARY VOLTAGE
117 V
Secondary
current
m A
Reference
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
No-load
voltage
V
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
100 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V model is VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
44133 6 333 10,4 T 70 B 2
44134 9 222 15,5 T 70 B 2
44135 12 167 20,7 T 70 B 2
44136 15 133 25,8 T 70 B 2
44137 18 111 30,8 T 70 B 2
44138 24 83 41,4 T 70 B 2
44139 2 X 6 2 x 167 2 x 10,4 T 70 B 2
44140 2 x 9 2 x 111 2 x 15,4 T 70 B 2
44141 2 x 12 2 x 83 2 x 20,7 T 70 B 2
44142 2 x 15 2 x 67 2 x 25,8 T 70 B 2
44143 2 x 18 2 x 56 2 x 30,8 T 70 B 2
44144 2 x 24 2 x 42 2 x 41,4 T 70 B 2
44750 6 383 10,5 T 50 B 2,3
44751 9 256 15,5 T 50 B 2,3
44752 12 192 21 T 50 B 2,3
44753 15 153 25,3 T 50 B 2,3
44754 18 128 31 T 50 B 2,3
44755 24 96 42 T 50 B 2,3
44756 2 x 6 2 x 192 2 x 10,5 T 50 B 2,3
44757 2 x 9 2 x 128 2 x 15,5 T 50 B 2,3
44758 2 x 12 2 x 96 2 x 21 T 50 B 2,3
44759 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3
44760 2 x 18 2 x 64 2 x 31 T 50 B 2,3
44761 2 x 24 2 x 48 2 x 42 T 50 B 2,3
44762 6 400 10,5 T 40 B 2,4
44763 9 267 15,5 T 40 B 2,4
44764 12 200 21 T 40 B 2,4
44765 15 160 25,3 T 40 B 2,4
44766 18 133 31 T 40 B 2,4
44767 24 100 42 T 40 B 2,4
44768 2 x 6 2 x 200 2 x 10,5 T 40 B 2,4
44769 2 x 9 2 x 133 2 x 15,5 T 40 B 2,4
44770 2 x 12 2 x 100 2 x 21 T 40 B 2,4
44771 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4
44772 2 x 18 2 x 67 2 x 31 T 40 B 2,4
44773 2 x 24 2 x 50 2 x 42 T 40 B 2,4
2-2,4 VA EI 30-15,5
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
10
PRIMARY VOLTAGE
230 V
Reference
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are non-
approved.
Those transformers meet all requirement of EN 61558-2-4
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585 441216 333 10,4 T 70 B 2
441229 222 15,5 T 70 B 2
4412312 167 20,7 T 70 B 2
4412415 133 25,8 T 70 B 2
4412518 111 30,8 T 70 B 2
4412624 83 41,4 T 70 B 2
441272 X 6 2 x 167 2 x 10,4 T 70 B 2
441282 x 9 2 x 111 2 x 15,4 T 70 B 2
441292 x 12 2 x 83 2 x 20,7 T 70 B 2
441302 x 15 2 x 67 2 x 25,8 T 70 B 2
44131*2 x 18 2 x 56 2 x 30,8 T 70 B 2
44132*2 x 24 2 x 42 2 x 41,4 T 70 B 2
44667 6 383 10,5 T 50 B 2,3
44668 9 256 15,5 T 50 B 2,3
44669 12 192 21 T 50 B 2,3
44670 15 153 25,3 T 50 B 2,3
44671 18 128 31 T 50 B 2,3
44672 24 96 42 T 50 B 2,3
44673 2 x 6 2 x 192 2 x 10,5 T 50 B 2,3
44674 2 x 9 2 x 128 2 x 15,5 T 50 B 2,3
44675 2 x 12 2 x 96 2 x 21 T 50 B 2,3
44676 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3
44487* 2 x 18 2 x 64 2 x 31 T 50 B 2,3
44488* 2 x 24 2 x 48 2 x 42 T 50 B 2,3
44677 6 400 10,5 T 40 B 2,4
44678 9 267 15,5 T 40 B 2,4
44679 12 200 21 T 40 B 2,4
44680 15 160 25,3 T 40 B 2,4
44681 18 133 31 T 40 B 2,4
44682 24 100 42 T 40 B 2,4
44683 2 x 6 2 x 200 2 x 10,5 T 40 B 2,4
44684 2 x 9 2 x 133 2 x 15,5 T 40 B 2,4
44685 2 x 12 2 x 100 2 x 21 T 40 B 2,4
44686 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4
44489* 2 x 18 2 x 67 2 x 31 T 40 B 2,4
44490* 2 x 24 2 x 50 2 x 42 T 40 B 2,4
2-2,4 VA EI 30-15,5
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
11
67 910
51
(Allows the use of a transformer
with 2 secondary windings)
79
51
67 910
51
Recommended layout for transformers
with 1 secondary winding
Primary winding
2 Secondary windings
1 Secondary winding
Primary winding
PRIMARY VOLTAGE
117 V
Reference
Protection
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
70 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Inherently short-circuits proof
30 V model is VDE EN 61558-2-6 certified
(production on request)
44169 6 383 10,5 T 70 B 2,3
44170 9 256 15,7 T 70 B 2,3
44171 12 192 21 T 70 B 2,3
44172 15 153 25,9 T 70 B 2,3
44173 18 128 31,4 T 70 B 2,3
44174 24 96 41,9 T 70 B 2,3
44175 2 X 6 2 x 192 2 x 10,5 T 70 B 2,3
44176 2 x 9 2 x 128 2 x 15,7 T 70 B 2,3
44177 2 x 12 2 x 96 2 x 21 T 70 B 2,3
44178 2 x 15 2 x 77 2 x 25,9 T 70 B 2,3
44179 2 x 18 2 x 64 2 x 31,4 T 70 B 2,3
44180 2 x 24 2 x 48 2 x 41,9 T 70 B 2,3
44774 6 450 10,5 T 50 B 2,7
44775 9 300 15,4 T 50 B 2,7
44776 12 225 21,1 T 50 B 2,7
44777 15 180 26,3 T 50 B 2,7
44778 18 150 30,9 T 50 B 2,7
44779 24 113 42 T 50 B 2,7
44780 2 x 6 2 x 225 2 x 10,5 T 50 B 2,7
44781 2 x 9 2 x 150 2 x 15,4 T 50 B 2,7
44782 2 x 12 2 x 113 2 x 21,1 T 50 B 2,7
44783 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7
44784 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7
44785 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7
44786 6 467 10,5 T 40 B 2,8
44787 9 311 15,4 T 40 B 2,8
44788 12 233 21,1 T 40 B 2,8
44789 15 187 26,3 T 40 B 2,8
44790 18 156 30,9 T 40 B 2,8
44791 24 117 42,1 T 40 B 2,8
44792 2 x 6 2 x 233 2 x 10,5 T 40 B 2,8
44793 2 x 9 2 x 156 2 x 15,4 T 40 B 2,8
44794 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8
44795 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8
44796 2 x 18 2 x 77 2 x 31,5 T 40 B 2,8
44797 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8
2,3-2,8 VA EI 30-18
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
12
PRIMARY VOLTAGE
230 V
Protection
Reference
Ambient
Temperature
°C
Rating
VA
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 18 V and 2 x 24 V models are non-
approved.
Those transformers meet all requirement of EN 61558-2-4
Items usually available on stock
EN 61558-2-6 EN 60950 UL 1585
441576 383 10,5 T 70 B 2,3
441589 256 15,7 T 70 B 2,3
4415912 192 21 T 70 B 2,3
4416015 153 25,9 T 70 B 2,3
4416118 128 31,4 T 70 B 2,3
4416224 96 41,9 T 70 B 2,3
441632 X 6 2 x 192 2 x 10,5 T 70 B 2,3
441642 x 9 2 x 128 2 x 15,7 T 70 B 2,3
441652 x 12 2 x 96 2 x 21 T 70 B 2,3
441662 x 15 2 x 77 2 x 25,9 T 70 B 2,3
44167*2 x 18 2 x 64 2 x 31,4 T 70 B 2,3
44168*2 x 24 2 x 48 2 x 41,9 T 70 B 2,3
44687 6 450 10,5 T 50 B 2,7
44688 9 300 15,4 T 50 B 2,7
44689 12 225 21,1 T 50 B 2,7
44690 15 180 26,3 T 50 B 2,7
44691 18 150 30,9 T 50 B 2,7
44692 24 113 42 T 50 B 2,7
44693 2 x 6 2 x 225 2 x 10,5 T 50 B 2,7
44694 2 x 9 2 x 150 2 x 15,4 T 50 B 2,7
44695 2 x 12 2 x 113 2 x 21,1 T 50 B 2,7
44696 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7
44491* 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7
44492* 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7
44697 6 467 10,5 T 40 B 2,8
44698 9 311 15,4 T 40 B 2,8
44699 12 233 21,1 T 40 B 2,8
44700 15 187 26,3 T 40 B 2,8
44701 18 156 30,9 T 40 B 2,8
44702 24 117 42,1 T 40 B 2,8
44703 2 x 6 2 x 233 2 x 10,5 T 40 B 2,8
44704 2 x 9 2 x 156 2 x 15,4 T 40 B 2,8
44705 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8
44706 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8
44493* 2 x 18 2 x 70 2 x 31,5 T 40 B 2,8
44494* 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8
44000 SERIES
ENCAPSULATED TRANSFORMERS
13
2,3-2,8 VA EI 30-18
SERIE 44000
PRIMARY VOLTAGE
117 V
PRIMARY VOLTAGE
117 V
800 44241 6 833 8,4 T 50 B 5
630 44242 9 556 12,6 T 50 B 5
400 44243 12 417 16,9 T 50 B 5
315 44244 15 333 21 T 50 B 5
315 44245 18 278 25,3 T 50 B 5
200 44246 24 208 33,7 T 50 B 5
400 44247 2 x 6 2 x 417 2 x 8,4 T 50 B 5
315 44248 2 x 9 2 x 278 2 x 12,6 T 50 B 5
200 44249 2 x 12 2 x 208 2 x 16,9 T 50 B 5
160 44250 2 x 15 2 x 167 2 x 21 T 50 B 5
160 44251 2 x 18 2 x 139 2 x 25,3 T 50 B 5
100 44252 2 x 24 2 x 104 2 x 33,7 T 50 B 5
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
150 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on secondary side (see diagram) to be assumed
by customer
51
51
6
10
79 6
10
79
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary windings 1 Secondary winding
Primary Primary
winding winding
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
200 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on secondary side (see diagram) to be assumed
by customer
67 910
51
51
51
6
10
79 6
10
79
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary windings 1 Secondary winding
Primary Primary
winding winding
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
3,2 VA EI 38-13,6
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
14
5 VA EI 42-14,8
SERIE 44000
630 44205 6 533 8 T 70 B 3,2
400 44206 9 356 12 T 70 B 3,2
315 44207 12 267 16 T 70 B 3,2
250 44208 15 213 20 T 70 B 3,2
200 44209 18 178 24,1 T 70 B 3,2
160 44210 24 133 32,1 T 70 B 3,2
315 44211 2 x 6 2 x 267 2 x 8 T 70 B 3,2
200 44212 2 x 9 2 x 178 2 x 12 T 70 B 3,2
160 44213 2 x 12 2 x 133 2 x 16 T 70 B 3,2
125 44214 2 x 15 2 x 107 2 x 20 T 70 B 3,2
100 44215 2 x 18 2 x 89 2 x 24 T 70 B 3,2
80 44216 2 x 24 2 x 67 2 x 32,1 T 70 B 3,2
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
230 V
Secondary
protection
mA
Secondary
protection
mA
4.5+0.5
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
5+0.5
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6 EN 60950
EN 61558-2-6 EN 60950
44000 SERIES
ENCAPSULATED TRANSFORMERS
15
3,2 VA EI 38-13,6
SERIE 44000
5 VA EI 42-14,8
SERIE 44000
630 44193 6 533 8 T 70 B 3,2
400 44194 9 356 12 T 70 B 3,2
315 44195 12 267 16 T 70 B 3,2
250 44196 15 213 20 T 70 B 3,2
200 44197 18 178 24,1 T 70 B 3,2
160 44198 24 133 32,1 T 70 B 3,2
315 44199 2 x 6 2 x 267 2 x 8 T 70 B 3,2
200 44200 2 x 9 2 x 178 2 x 12 T 70 B 3,2
160 44201 2 x 12 2 x 133 2 x 16 T 70 B 3,2
125 44202 2 x 15 2 x 107 2 x 20 T 70 B 3,2
100 44203 2 x 18 2 x 89 2 x 24 T 70 B 3,2
80 44204* 2 x 24 2 x 67 2 x 32,1 T 70 B 3,2
800 44229 6 833 8,4 T 50 B 5
630 44230 9 556 12,6 T 50 B 5
400 44231 12 417 16,9 T 50 B 5
315 44232 15 333 21 T 50 B 5
315 44233 18 278 25,3 T 50 B 5
200 44234 24 208 33,7 T 50 B 5
400 44235 2 x 6 2 x 417 2 x 8,4 T 50 B 5
315 44236 2 x 9 2 x 278 2 x 12,6 T 50 B 5
200 44237 2 x 12 2 x 208 2 x 16,9 T 50 B 5
160 44238 2 x 15 2 x 167 2 x 21 T 50 B 5
160 44239 2 x 18 2 x 139 2 x 25,3 T 50 B 5
100 44240* 2 x 24 2 x 104 2 x 33,7 T 50 B 5
PRIMARY VOLTAGE
117 V
PRIMARY VOLTAGE
117 V
2,5 44313 6 2667 7,4 T 50 B 16
2,0 44314 9 1778 11,1 T 50 B 16
1,25 44315 12 1333 14,7 T 50 B 16
1 44316 15 1067 18,4 T 50 B 16
1 44317 18 889 22,1 T 50 B 16
0,63 44318 24 667 29,3 T 50 B 16
1,25 44319 2 x 6 2 x 1333 2 x 7,4 T 50 B 16
1 44320 2 x 9 2 x 889 2 x 11,1 T 50 B 16
0,63 44321 2 x 12 2 x 667 2 x 14,7 T 50 B 16
0,5 44322 2 x 15 2 x 533 2 x 18,4 T 50 B 16
0,5 44323 2 x 18 2 x 444 2 x 22 T 50 B 16
0,315 44324 2 x 24 2 x 333 2 x 29,3 T 50 B 16
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
300 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on primary side (see diagram) to be assumed
by customer
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
400 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on secondary side (see diagram) to be assumed
by customer
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Secondary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
10 VA EI 48-16,8
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
16
16 VA EI 54-18,8
SERIE 44000
125 44277 6 1667 7,2 T 50 B 10
125 44278 9 1111 10,8 T 50 B 10
125 44279 12 833 14,4 T 50 B 10
125 44280 15 667 18,1 T 50 B 10
125 44281 18 556 21,6 T 50 B 10
125 44282 24 417 28,9 T 50 B 10
125 44283 2 x 6 2 x 833 2 x 7,2 T 50 B 10
125 44284 2 x 9 2 x 556 2 x 10,8 T 50 B 10
125 44285 2 x 12 2 x 417 2 x 14,4 T 50 B 10
125 44286 2 x 15 2 x 333 2 x 18,1 T 50 B 10
125 44287 2 x 18 2 x 278 2 x 21,6 T 50 B 10
125 44288 2 x 24 2 x 208 2 x 28,9 T 50 B 10
71
71
71
8 8
14
9
13
9
1413
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
8 9
13 14
61
61
61
7 7
12
8
11
8
1211
Recommended layout
for transformers with
1 secondary winding
(Allows the use of a
transformer with
2 secondary windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
7 8 11 12
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
230 V
Secondary
protection
mA
Primary
protection
mA
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6 EN 60950
EN 61558-2-6 EN 60950
44000 SERIES
ENCAPSULATED TRANSFORMERS
17
10 VA EI 48-16,8
SERIE 44000
16 VA EI 54-18,8
SERIE 44000
63 44265 6 1667 7,2 T 50 B 10
63 44266 9 1111 10,8 T 50 B 10
63 44267 12 833 14,4 T 50 B 10
63 44268 15 667 18,1 T 50 B 10
63 44269 18 556 21,6 T 50 B 10
63 44270 24 417 28,9 T 50 B 10
63 44271 2 x 6 2 x 833 2 x 7,2 T 50 B 10
63 44272 2 x 9 2 x 556 2 x 10,8 T 50 B 10
63 44273 2 x 12 2 x 417 2 x 14,4 T 50 B 10
63 44274 2 x 15 2 x 333 2 x 18,1 T 50 B 10
63 44275 2 x 18 2 x 278 2 x 21,6 T 50 B 10
63 44276* 2 x 24 2 x 208 2 x 28,9 T 50 B 10
2,500 44301 6 2667 7,4 T 50 B 16
2,000 44302 9 1778 11,1 T 50 B 16
1,25 44303 12 1333 14,7 T 50 B 16
1 44304 15 1067 18,4 T 50 B 16
1 44305 18 889 22,1 T 50 B 16
0,63 44306 24 667 29,3 T 50 B 16
1,25 44307 2 x 6 2 x 1333 2 x 7,4 T 50 B 16
1 44308 2 x 9 2 x 889 2 x 11,1 T 50 B 16
0,63 44309 2 x 12 2 x 667 2 x 14,7 T 50 B 16
0,5 44310 2 x 15 2 x 533 2 x 18,4 T 50 B 16
0,5 44311 2 x 18 2 x 444 2 x 22 T 50 B 16
0,315 44312* 2 x 24 2 x 333 2 x 29,3 T 50 B 16
3.5+0.5
PRIMARY VOLTAGE
117 V
PRIMARY VOLTAGE
117 V
315 44385 6 5000 6,9 T 50 B 30
315 44386 9 3333 10,3 T 50 B 30
315 44387 12 2500 13,8 T 50 B 30
315 44388 15 2000 17,2 T 50 B 30
315 44389 18 1667 20,8 T 50 B 30
315 44390 24 1250 27,7 T 50 B 30
315 44391 2 x 6 2 x 2500 2 x 6,9 T 50 B 30
315 44392 2 x 9 2 x 1667 2 x 10,3 T 50 B 30
315 44393 2 x 12 2 x 1250 2 x 13,8 T 50 B 30
315 44394 2 x 15 2 x 1000 2 x 17,2 T 50 B 30
315 44395 2 x 18 2 x 833 2 x 20,8 T 50 B 30
315 44396 2 x 24 2 x 625 2 x 27,7 T 50 B 30
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
550 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on primary side (see diagram) to be assumed
by customer
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94 VO
Degree of protection IP 00
700 grams weight
Resin class B CEI 85 (20 000 h testing to CEI 126)
Fuse protection on primary side (see diagram) to be assumed
by customer
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Primary
protection
mA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
22 VA EI 60-21
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
18
30 VA EI 66-23
SERIE 44000
250 44444 6 3667 6,8 T 50 B 22
250 44445 9 2444 10,3 T 50 B 22
250 44446 12 1833 13,7 T 50 B 22
250 44447 15 1467 17,1 T 50 B 22
250 44448 18 1222 20,5 T 50 B 22
250 44449 24 917 27,3 T 50 B 22
250 44450 2 x 6 2 x 1833 2 x 6,8 T 50 B 22
250 44451 2 x 9 2 x 1222 2 x 10,3 T 50 B 22
250 44452 2 x 12 2 x 917 2 x 13,7 T 50 B 22
250 44453 2 x 15 2 x 733 2 x 17,1 T 50 B 22
250 44454 2 x 18 2 x 611 2 x 20,5 T 50 B 22
250 44455 2 x 24 2 x 458 2 x 27,3 T 50 B 22
89
13 14
71
71
71
8
13
9
14
8
13
9
14
Recommended layout
for transformers
with 1 secondary winding
(Allows the use of a
transformer with 2 secondary
windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
81
81
81
9 9
1615161510 10
Recommended layout
for transformers
with 1 secondary winding
(Allows the use of a
transformer with 2 secondary
windings)
2 Secondary 1 Secondary
windings winding
Primary Primary
winding winding
9
10 15 16
PRIMARY VOLTAGE
230 V
PRIMARY VOLTAGE
230 V
Primary
protection
mA
Primary
protection
mA
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
30 V and 36 V models are VDE EN 61558-2-6 certified
(production on request)
Insulation voltage 4 KV
100 % tested production
Certification : CCA procedure on request
*To be noted : 2 x 24 V model is non-approved.
Those transformers meet all requirement of EN 61558-2-4
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
Reference
Secondary
voltage
V
Secondary
current
m A
No-load
voltage
V
Ambient
Temperature
°C
Rating
VA
EN 61558-2-6 EN 60950
EN 61558-2-6 EN 60950
44000 SERIES
ENCAPSULATED TRANSFORMERS
19
22 VA EI 60-21
SERIE 44000
30 VA EI 66-23
SERIE 44000
125 44432 6 3667 6,8 T 50 B 22
125 44433 9 2444 10,3 T 50 B 22
125 44434 12 1833 13,7 T 50 B 22
125 44435 15 1467 17,1 T 50 B 22
125 44436 18 1222 20,5 T 50 B 22
125 44437 24 917 27,3 T 50 B 22
125 44438 2 x 6 2 x 1833 2 x 6,8 T 50 B 22
125 44439 2 x 9 2 x 1222 2 x 10,3 T 50 B 22
125 44440 2 x 12 2 x 917 2 x 13,7 T 50 B 22
125 44441 2 x 15 2 x 733 2 x 17,1 T 50 B 22
125 44442 2 x 18 2 x 611 2 x 20,5 T 50 B 22
125 44443* 2 x 24 2 x 458 2 x 27,3 T 50 B 22
160 44373 6 5000 6,9 T 50 B 30
160 44374 9 3333 10,3 T 50 B 30
160 44375 12 2500 13,8 T 50 B 30
160 44376 15 2000 17,2 T 50 B 30
160 44377 18 1667 20,8 T 50 B 30
160 44378 24 1250 27,7 T 50 B 30
160 44379 2 x 6 2 x 2500 2 x 6,9 T 50 B 30
160 44380 2 x 9 2 x 1667 2 x 10,3 T 50 B 30
160 44381 2 x 12 2 x 1250 2 x 13,8 T 50 B 30
160 44382 2 x 15 2 x 1000 2 x 17,2 T 50 B 30
160 44383 2 x 18 2 x 833 2 x 20,8 T 50 B 30
160 44384* 2 x 24 2 x 625 2 x 27,7 T 50 B 30
For boxes with 2 lugs and pin type output, add suffix 1 to the reference of the standard transformer (example : 44198-1)
For boxes with 2 lugs and 2,8 «faston» output, add suffix 2 to the reference of the standard transformer (example : 44199-2)
For boxes with 4 lugs and pin type output, add suffix 3 to the reference of the standard transformer (example : 44200-3)
For boxes with 4 lugs and 2,8 «faston» output, add suffix 4 to the reference of the standard transformer (example : 44201-4)
These models are not available on stock.
Series 44000 transformers can be
equiped with boxes with lugs and also
2,8 «faston» terminal tags while still
conforming to the specifications in
the standard references.
•••••••
••
•••••
X
LHLH
P
P
O
Y
OX
••••••••
••••••••
••••••
7X5.0
1
16
8
9
7X5.0
1
14
7
8
6X5.0
6X5.0
•••••
1
10
5
6
4X5.0
5X5.0
•••••
••
1
14
7
8
13X2.5
••••••
••••••
5X5.0
1
12
6
7
11X2.5
••
1
10
5
6
7.5
5X5.0
7.5
5.0 5.0
6X5.0
EI 38 EI 42 EI 48
EI 54 EI 60 EI 66
BOXES WITH FIXING SUPPORT
SERIE 44000
44000 SERIES
ENCAPSULATED TRANSFORMERS
20
CIRCUIT LPHXYØ
± 0,50 ± 0,40 ± 0,40 ± 0,50 ± 0,50 ±0,3
EI 38 X 13,6 55,6 34,9 28,1 47,5 3,2
EI 42 X 14,8 64 37 32,3 55,0 4,2
EI 48 X 16,8 69 42,3 34,6 60 4,2
EI 54 X 18,8 74 47,3 38,8 65 4,2
EI 60 X 21 81,5 53,3 44,7 72,5 43,5 4,2
EI 66 X 23 87,2 58,6 48,5 77,5 47,5 4,2
PRIMARY VOLTAGE
230 V
Reference
Protection
45000 SERIES
ENCAPSULATED TRANSFORMERS
21
1 VA UI 21
SERIE 45000
Ambient
Temperature
°C
Secondary
voltage
V
No-load
voltage
V
Secondary
current
m A
UI 21 230 V 1 VA
230 V supply voltage by series/parallel
connection
Vacuum filling
One compartiment housing 1 VA
Two compartments bobbins 0,8 VA
Degree of protection IP 00
50 grams weight
Resin UL 94 VO
Design protection against short-circuits
Insulation voltage 4 KV
100 % tested production
Conform to EN 61558 - UL 506
1 VA
Type 1 VA
Primary
windings
Secondary
windings
25
12 7
QUALITY IN SERIES
45001 6 167 11,4 T 70 B
45002 9 111 17 T 70 B
45003 12 83 22,8 T 70 B
45004 15 67 28,5 T 70 B
45005 18 56 34,2 T 70 B
45006 24 42 45,6 T 70 B
PRIMARY VOLTAGE
115 V - 230 V •115 V- 230 V supply voltage
by series/parallel connection
Vacuum filling
Two compartments bobbins
Degree of protection IP 00
Resin class UL 94 VO
Ambient
Temperature
°C
No-load
voltage
V
Protection
Secondary
voltage
V
Secondary
current
m A
Reference
UI 30 x 5,5 2 VA
45292 2 x 6 2 x 167 2 x 10,2 T 70 B
45293 2 x 9 2 x 111 2 x 15,9 T 70 B
45294 2 x12 2 x 83 2 x 20,4 T 70 B
45295 2 x15 2 x 67 2 x 25,5 T 70 B
45296 2 x18 2 x 56 2 x 30,6 T 70 B
45297 2 x24 2 x 42 2 x 40,8 T 70 B
UI 30 x 5,5 Secondary protection mA 3 VA
250 45013 2 x 6 2 x 250 2 x 9,8 T 70 B
160 45014 2 x 9 2 x 167 2 x 14,7 T 70 B
125 45015 2 x 12 2 x 125 2 x 19,6 T 70 B
100 45016 2 x 15 2 x 100 2 x 24,5 T 70 B
80 45017 2 x 18 2 x 83 2 x 29,5 T 70 B
63 45018 2 x 24 2 x 63 2 x 39,3 T 70 B
UI 30 x 7,5 Secondary protection mA 4 VA
315 45019 2 x 6 2 x 333 2 x 9,4 T 70 B
250 45020 2 x 9 2 x 222 2 x 14,0 T 70 B
160 45021 2 x 12 2 x 167 2 x 18,6 T 70 B
125 45022 2 x 15 2 x 133 2 x 23,3 T 70 B
125 45023 2 x 18 2 x 111 2 x 28,0 T 70 B
80 45024 2 x 24 2 x 83 2 x 37,4 T 70 B
UI 30 x 10,5 Secondary protection mA 6 VA
500 45025 2 x 6 2 x 500 2 x 8,1 T 70 B
315 45026 2 x 9 2 x 333 2 x 12,1 T 70 B
250 45027 2 x 12 2 x 250 2 x 16,2 T 70 B
200 45028 2 x 15 2 x 200 2 x 20,2 T 70 B
160 45029 2 x 18 2 x 167 2 x 24,3 T 70 B
125 45030 2 x 24 2 x 125 2 x 32,3 T 70 B
UI 30 x 16,5 Primary protection mA 10 VA
125/63 45031 2 x 6 2 x 833 2 x 7,9 T 50 B
125/63 45032 2 x 9 2 x 556 2 x 11,9 T 50 B
125/63 45033 2 x 12 2 x 417 2 x 15,9 T 50 B
125/63 45034 2 x 15 2 x 333 2 x 19,8 T 50 B
125/63 45035 2 x 18 2 x 278 2 x 23,7 T 50 B
125/63 45036 2 x 24 2 x 208 2 x 31,7 T 50 B
CIRCUIT RATING
DIMENSION A
WEIGHT
UI 30 x 5,5 2 VA/3 VA A = 17 mm 125 g
UI 30 x 7,5 4 VA A = 19 mm 150 g
UI 30 x 10,5 6 VA A = 22 mm 185 g
UI 30 x 16,5 10 VA A = 28 mm 260 g
1357
16 14 12 10
1357
16 14 12 10
1357
16 14 12 10
1357
16 14 12 10
Secondary voltage Double the
doubled secondary current
Possible primary
connections
Possible secondary
connections
230 V 115 V
3-10 VA UI 30
SERIE 45000
45000 SERIES
ENCAPSULATED TRANSFORMERS
22
QUALITY IN SERIES
PRIMARY VOLTAGE
115 V - 230 V
Reference
Ambient
Temperature
°C
No-load
voltage
V
Secondary
current
m A
Secondary
voltage
V
Primary
protection
115 V/230 V
mA
UI 39 x 8 10 VA
125/63 45037 2 x 6 2 x 833 2 x 8,2 T 50 B
125/63 45038 2 x 9 2 x 555 2 x 12,3 T 50 B
125/63 45039 2 x 12 2 x 416 2 x 16,4 T 50 B
125/63 45040 2 x 15 2 x 333 2 x 20,5 T 50 B
125/63 45041 2 x 18 2 x 277 2 x 24,6 T 50 B
125/63 45042 2 x 24 2 x 208 2 x 32,8 T 50 B
UI 39 x 10,2 14 VA
160/80 45043 2 x 6 2 x 1167 2 x 7,5 T 50 B
160/80 45044 2 x 9 2 x 778 2 x 10,9 T 50 B
160/80 45045 2 x 12 2 x 583 2 x 15,0 T 50 B
160/80 45046 2 x 15 2 x 467 2 x 18,7 T 50 B
160/80 45047 2 x 18 2 x 389 2 x 22,4 T 50 B
160/80 45048 2 x 24 2 x 292 2 x 30,2 T 50 B
UI 39 x 13,5 18 VA
200/100 45049 2 x 6 2 x 1500 2 x 7,4 T 50 B
200/100 45050 2 x 9 2 x 1000 2 x 11,0 T 50 B
200/100 45051 2 x 12 2 x 750 2 x 14,7 T 50 B
200/100 45052 2 x 15 2 x 600 2 x 18,3 T 50 B
200/100 45053 2 x 18 2 x 500 2 x 22,0 T 50 B
200/100 45054 2 x 24 2 x 375 2 x 29,4 T 50 B
UI 39 x 17 24 VA
250/125 45055 2 x 6 2 x 2000 2 x 7,1 T 50 B
250/125 45056 2 x 9 2 x 1333 2 x 10,6 T 50 B
250/125 45057 2 x 12 2 x 1000 2 x 14,1 T 50 B
250/125 45058 2 x 15 2 x 800 2 x 17,6 T 50 B
250/125 45059 2 x 18 2 x 667 2 x 21,2 T 50 B
250/125 45060 2 x 24 2 x 500 2 x 28,3 T 50 B
UI 39 x 21 30 VA
315/160 45061 2 x 6 2 x 2500 2 x 6,7 T 50 B
315/160 45062 2 x 9 2 x 1667 2 x 10,15 T 50 B
315/160 45063 2 x 12 2 x 1250 2 x 13,5 T 50 B
315/160 45064 2 x 15 2 x 1000 2 x 16,8 T 50 B
315/160 45065 2 x 18 2 x 833 2 x 20,2 T 50 B
315/160 45066 2 x 24 2 x 625 2 x 27,0 T 50 B
Fuse protection in secondary winding (see diagram)
Insulation voltage 4 KV
100 % tested production
Conform to EN 61558
Approval under process
UL 506 approved
CIRCUIT RATING
DIMENSION A
WEIGHT
UI 39 x 8 10 VA A = 22 mm 285 g
UI 39 x 10,2 14 VA A = 24 mm 335 g
UI 39 x 13,5 18 VA A = 27 mm 405 g
UI 39 x 17 24 VA A = 31 mm 480 g
UI 39 x 21 30 VA A = 35 mm 550 g
1469
19 17 14 12
1469
19 17 14 12
1469
19 17 14 12
1469
19 17 14 12
Secondary voltage Double the
doubled secondary current
sec 1 sec 2 sec 1 sec 2
Possible primary
connections
Possible secondary
connections
230 V 115 V
45000 SERIES
ENCAPSULATED TRANSFORMERS
23
10-30 VA UI 39
SERIE 45000
PRIMARY VOLTAGE
115 V - 230 V
115 V- 230 V supply voltage
by series/parallel connection
Vacuum filling
Two compartments bobbins
Degree of protection IP 00
Resin class UL 94 VO
Fuse protection in secondary winding (see diagram)
Insulation voltage 4 KV
100 % tested production
Conform to EN 61558
Approval under process
UL 506 approved
CIRCUIT RATING AB C WEIGHT
UI 48 x 17 40 VA 38,5 13,5 83 760 g
UI 48 x 26 60 VA 48,5 14,5 86 1060 g
14 9
23 20 17
12
14
14 9
12
14 9
12
14 9
12
23 20 17 14 23 20 17 14 23 20 17 14
Secondary voltage Double the
doubled secondary current
Possible primary
connections
Possible secondary
connections
230 V 115 V
Primary
protection
115/230 V
mA
Reference
No-load
voltage
V
Secondary
voltage
V
Secondary
current
m A
Ambient
Temperature
°C
400/200 45067 2 x 6 2 x 3333 2 x 6,7 T 50 B
400/200 45068 2 x 9 2 x 2222 2 x 10,0 T 50 B
400/200 45069 2 x 12 2 x 1667 2 x 13,4 T 50 B
400/200 45070 2 x 15 2 x 1333 2 x 16,7 T 50 B
400/200 45071 2 x 18 2 x 1111 2 x 20,1 T 50 B
400/200 45072 2 x 24 2 x 833 2 x 26,8 T 50 B
630/315 45073 2 x 6 2 x 5000 2 x 6,6 T 50 B
630/315 45074 2 x 9 2 x 3333 2 x 9,9 T 50 B
630/315 45075 2 x 12 2 x 2500 2 x 13,1 T 50 B
630/315 45076 2 x 15 2 x 2000 2 x 16,4 T 50 B
630/315 45077 2 x 18 2 x 1667 2 x 19,7 T 50 B
630/315 45078 2 x 24 2 x 1250 2 x 26,3 T 50 B
U I 48 x 17 40 VA
U I 48 x 26 60 VA
40-60 VA UI 48
SERIE 45000
45000 SERIES
ENCAPSULATED TRANSFORMERS