SXE15 Series Single output DC-DC CONVERTERS 10.8-15 W High Efficiency DC-DC Converters 1 * High efficiency topology, 87% typical at 5 V * Wide operating temperature, up to and exceeding 70 C (natural convection) * 90% to 110% output trim * No minimum load * Overvoltage protection * Remote ON/OFF control * Available RoHS compliant The SXE15 is a new high efficiency open frame isolated 15 Watt converter series in an industry standard footprint. All models in the series feature an input voltage range of 33 Vdc to 75 Vdc and are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V and 1.8 V. The output voltage on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the models are 87% for the 5 V, 86% for the 3.3 V, 85% for the 2.5 V and 12 V and 83% for the 1.8 V version. The SXE15 series also has a remote ON/OFF capability with active high or active low logic. Overcurrent and overvoltage protection features are included as standard. With full international safety approval including EN60950 and cUL1950, the SXE15 reduces compliance costs and time to market. TUV 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25 C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage adjustability 90% to 110% Total error band (See Note 13) 4% max. Line regulation Low line to high line 1.8 V and 2.5 V models 3.3 V and 5 V models 0.5% max. 0.1% max. Load regulation Full load to min. load 1.8 V model 2.5 V model 3.3 V and 5 V models 2.0% max. 1.5% max. 0.5% max. Minimum load (See Note 12) Overshoot At turn-on and turn-off 1.8 V and 2.5 V models 3.3 V and 5 V models 0% Undershoot Ripple and noise (See Note 1) 5 Hz to 20 MHz Transient response (See Note 2) Typical deviation 4% max. None None 1.8 V and 2.5 V models 3.3 V and 5 V models 40 mV pk-pk 14 mV rms 70 mV pk-p 20 mV rms 1.8 V and 2.5 V models 150 mV 3.3 V and 5 V models 100 mV 400 s recovery to within total error band INPUT SPECIFICATIONS Conducted emissions Radiated emissions Immunity: ESD air ESD contact Radiated field enclosure Conducted (dc power) Conducted (signal) Input transients EN55022 (See Note 3) Level A EN55022 (See Note 3) Level B EN55022 (See Longform Datasheet) Level B EN61000-4-2 8 kV, 15 kV EN61000-4-2 6 kV, 8 kV EN61000-4-3 10 V/m EN61000-4-6 10 V EN61000-4-6 10 V (See Note 11) ETS 300 132-2, ETR 283 GENERAL SPECIFICATIONS Efficiency See table Operational insulation Input/output Switching frequency Fixed Approvals and standards (See Notes 5) 1500 Vdc 265 kHz typ. UL/cUL1950, EN60950 TUV Rheinland Material flammability UL94V-0 Weight 12 g (0.42 oz) Coplanarity Input voltage range 48 Vin nominal Input current No load Remote OFF 35 mA max. 25 mA max. Input current (max.) (See Note 4) 0.55 A max. @ Io max. and Vin = 33-75 Vdc Input reflected ripple (See Note 6) 5 mA (pk-pk) typ. Active high remote ON/OFF Logic compatibility ON OFF 33-75 Vdc (See Note 8) Open collector ref to -input Open circuit or >2 Vdc <1.2 Vdc Undervoltage lockout Power up Power down Start-up time (See Note 7) Power up Remote ON/OFF 33 V (typ.) 30 V (typ.) 1.5 ms (typ.) 2.5 ms (typ.) MTBF Representative model: 150 m MIL-HDBK-217F 1,790,000 hours 48S05J @ 48 Vin, 40 C, 100% load ground benign BELLCORE 332 >1,500,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance (See Note 9) Operating ambient temp. (3.3 V and 5 V) Operating ambient temp. (1.8 V, 2.5 V and 12 V) Non-operating (All models) -40 C to +65 C -40 C to +70 C -40 C to +120 C File Name: sxe15s.pdf Rev (02): 08 Dec 2005 SXE15 Series Single output DC-DC CONVERTERS 10.8-15 W High Efficiency DC-DC Converters 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT POWER (MAX.) INPUT VOLTAGE OUTPUT VOLTAGE OVP OUTPUT CURRENT OUTPUT CURRENT (MIN.) (MAX.) EFFICIENCY (TYP.) REGULATION LINE MODEL NUMBER (8,14,15) LOAD 10.8 W 33-75 Vdc 2.3 Vdc 1.8 V 0A 6A 83% 0.3% 2.0% SXE15-48S1V8J 15 W 33-75 Vdc 3.2 Vdc 2.5 V 0A 6A 85% 0.3% 1.5% SXE15-48S2V5J 15 W 33-75 Vdc 4 Vdc 3.3 V 0A 4.5 A 86% 0.1% 0.5% SXE15-48S3V3J 15 W 33-75 Vdc 6 Vdc 5V 0A 3A 87% 0.1% 0.5% SXE15-48S05J 12 V 0A 1.25 A 85% 0.1% 0.5% SXE15-48S12J 15 W 33-75 Vdc 15 Vdc (10) Notes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Measured as per recommended set-up. See Application Note 116 for details. di/dt = 0.1 A/s, Vin = 48 Vdc, Tc = 25 C, load change = 0.5 lo max. to 0.75 lo max. and 0.75 lo max. to 0.5 lo max. The SXE15 meets level A and level B conducted emissions only with external components connected before the input pins to the converter. See Application Note 116 for details. Recommended input fusing is a 2 A HRC 200 V rated fuse. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. Measured with external Pi filter. See Application Note 116 for further details. Start-up into resistive load. Active low remote on/off is available. Standard product is active high. Designate with the Suffix `-R' e.g. SXE15-48S05-RJ. Operating ambient temperatures are specified at natural convection. Higher operating temperatures are possible with increased airflow. See Application Note 116 for further details. SXE15-48S12J below 0.2 A loading. OVP is TVS and 17 V typical. Signal line assumed < 3 m in length. A 5% minimum load is required to maintain the output voltage regulation over all operating conditions for the SXE15-48S12J. This parameter is calculated at worst case line, load, temperature and initial settings. The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. PROTECTION 1.905 (48.39) overall length 1.150 (29.21) 1.390 (35.31) TOP VIEW 1.885 (47.88) leadframe length 0.070 (1.78) MAX 0.335 (8.51) MAX SIDE VIEW 0.010 (0.25) MIN 1.812 (46.03) Tolerence: .015 (.38) Recommended Land & Hole Pattern 1.575 (40.01) 0.197 (5.00) 0.394 (10.01) 1.812 (46.02) BOTTOM VIEW 0.502 (12.75) 0.130 (3.30) 1.181 (30.00) 0.069 (1.74) 1.378 (35.00) 0.100 (2.54) 12 places 0.197 (5.00) All Dimensions in Inches [mm] 0.394 (10.01) 1.181 (30.00) 1.378 (35.00) 1.575 (40.01) PIN CONNECTIONS PIN NUMBER FEATURE 1 Vout + 2 Vout - Continuous 3 N/C 4 Trim 5 N/C 6 N/C 7 N/C 8 On/Off 9 N/C 10 N/C 11 Vin - 12 Vin + CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. 0.161 (4.09) 1 Latching clamp ETS300-132-2, input voltage and current requirements 0.125 (3.18) 0.053 (1.36) Overvoltage Central office interface A 1.200 (30.48) 1.812 (46.02) o.050 (o1.27) Non-Skid Retaining Pins, 2 Places 0.477 (12.11) Short circuit TELECOM SPECIFICATION 0.063 (1.60) o0.063 (o1.60) 0.047 (1.18) International Safety Standard Approvals UL/cUL 1950 3rd edition. File No. E135734 TUV TUV Rheinland. File No. 10401-3336-35841. Licence No. 40004290 Datasheet (c) Artesyn Technologies(R) 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: Application Note Longform Data Sheet www.artesyn.com File Name: sxe15s.pdf Rev (02): 08 Dec 2005