Connection Data
Detachable clamps No
Type of electric connection Screw connection
Application
Model Basic device
Suitable for monitoring of magnetic switches Yes
Suitable for monitoring of proximity switches Yes
Suitable for monitoring of emergency-stop circuits Yes
Suitable for monitoring of optoelectronic protection equipment Yes
Suitable for monitoring of position switches Yes
Suitable for monitoring of valves No
Output circuit
Enabling paths Normally open contact
Signaling paths Opener
Contact material Ag-alloy, gold-plated
Rated switching voltage, enabling paths AC 230 V
Rated switching voltage, signaling paths AC 230 V
Max. thermal current Ith, enabling paths 8 A
Max. thermal current Ith, signaling paths 5 A
Max. total current I2 of all current path 25 A²
Application category AC-15 (NO) Ue 230V, Ie 3A
Application category DC-13 (NO) Ue 24V, Ie 3A
Short-circuit protection (NO), max. fuse insert 6 A class gG fuse, fuse integral
Mechanical life 107 switching cycles
Outputs, signalling function, undelayed, with contact 0
Outputs, signalling function, delayed, with contact 0
Outputs, safe, undelayed, with contact 4
Outputs, safe, delayed, with contact 0
Control circuit
Nominal output voltage DC 24 V
Input current (safety circuit / reset circuit) 25 mA
max. peak current (safety circuit / reset circuit) 100 mA
Response time tA1 350 ms
Response time tA2 350 ms
Min. switch-on time 100 ms
Recovery time tW 750 ms
Release time tR 10 ms
Permissable test pulse time tTP 1 ms
max. resistivity, per channel ≤ (5 + (1,176 x UB / UN - 1) x 100) Ω
Evaluation inputs 2-channel
Page: 2 of 3