Remote
Systems
5.81-800-543-8390 WWW.BALLUFF.COM
RXE
Mechanical
limit SW
RST
[]
Detector
[]
Transmitter
[]
Output Sensor
BES-RXT-1202-J-01
N/A
BES-RST-1202-J-01
Number of Signals
Housing Size
Mounting
Rated Sn / Gap Distance
Assured Sn / Gap Distance
Single Signal Remotes
M12 - M18
Sn 1.5 - 5.0mm Passive Remote Systems
Transmitter
Exclusive Proximity Sensors
Exclusive Proximity AND Signal
Mechanical Limit Switch
Output Sensor
PNP Output
NPN Output
Sensing Distance
Rated operational voltage
Short circuit protection
Current Consumption
Load Capacity
Operation Frequency
Ambient temperature range
Function indication
Environmental protection (per IEC529)
Housing material
Sensing face material
Cable Material
Cable Length / Diameter / AWG
BES-RXE-1202-P-02
BES-RXE-1202-N-02
BES-RXT-1805-J-01
BES-RAT-1805
BES-RST-1805
BES-RXE-1805-P-02
BES-RXE-1805-N-02
0..2.0mm non-Flush / 0..1.6mm flush
0..+50 C
no
IP67
Nickel Plated Brass
ABS + PBT
PVC
1M, 5mm, 2X20AWG
24V DC ± 5%
yes
£ 25mA
max. 100mA
25 Hz
0..+50 C
yes
IP67
Nickel Plated Brass
ABS + PBT
PVC
2M, 5mm, 3X20AWG
0..5.0mm non-Flush / 0..4.0 flush
0..+50 C
no
IP67
Nickel Plated Brass
ABS + PBT
PVC
1M, 5mm, 2X20AWG
24V DC ± 5%
yes
£ 25mA
max. 100mA
25 Hz
0..+50 C
yes
IP67
Nickel Plated Brass
ABS + PBT
PVC
2M, 5mm, 3X20AWG
Basic Remote Sensor System Wiring Schematics · RX · RA · RS series
Exclusive Proximity Sensors
Exclusive Proximity AND Signal
Mechanical Limit Switch
Transmitter Output Sensorç•••••èTransmitter Output Sensorç•••••è
1 Signal
M12 X 1
flush/non flush
2mm
0...1.6mm
M12 X 1
flush/non flush
1 Signal
M18 X 1
flush/non flush
5mm
0...4.0mm
M18 X 1
flush/non flush
RXD RXT RXE
[]Detector []Transmitter []Output Sensor
RXD
RXE
RXD
RAT
T
[]
Detector
[]
Transmitter
[]
Output Sensor
5
Remote
Systems
5.9
1-800-543-8390 WWW.BALLUFF.COM
Single & Multiple Signal
Remotes M18 - M30
Sn 10mm, 5mm
Passive Remote Systems
1 Signal
M30 X 1
flush/non flush
10mm
0...8.0mm
M30 X 1
flush/non flush
8 Signals
M18 X 1
flush/non flush
5mm
1.0...4.0mm
M18 X 1
flush/non flush
BES-RXE-3010-P-02
BES-RXE-3010-N-02
0..5.0mm non-Flush / 0..4.0 non flush
0..+50 C
no
IP67
Nickel Plated Brass
ABS + PBT
PVC
1M, 7mm, 12X26AWG
24V DC ± 5%
yes
£ 40mA
max. 50mA per Output
3.2 Hz
0..+50 C
yes
IP67
Nickel Plated Brass
ABS + PBT
PVC
2M, 7mm, 12X26AWG
0..10mm non-Flush / 0..10mm flush
0..+50 C
no
IP67
Nickel Plated Brass
ABS + PBT
PVC
1M, 5mm, 2X20AWG
24V DC ± 5%
yes
£ 25mA
max. 100mA
25 Hz
0..+50 C
yes
IP67
Nickel Plated Brass
ABS + PBT
PVC
2M, 5mm, 3XAWG
BES-RFTA-1805-S-01
BES-RFEA-1805-PS-02
BES-RFEA-1805-NS-02
Transmitter Output Sensorç•••••èTransmitter Output Sensorç•••••è
BES-RXT-3010-J-01
BES-RAT-3010-J-01
BES-RST-3010-J-01
Remote
Systems
5.10 1-800-543-8390 WWW.BALLUFF.COM
8 Signals
M30 X 1
flush/non flush
2.0...10.0mm
2.0...8.0mm
M30 X 1
flush/non flush
8 Signals
M30 X 1
Non flush
2.0...18.0mm
2.0...16.0mm
M30 X 1
Non flush
8 Signal Remotes
M12 - M18
Sn 1.5 - 5.0mm Passive Remote Systems
Number of Signals
Housing Size
Mounting
Rated Sn / Gap Distance
Assured Sn / Gap Distance
Transmitter
Output Sensor
PNP Output
NPN Output
Sensing Distance
Rated operational voltage
Short circuit protection
Current Consumption
Load Capacity
Operation Frequency
Ambient temperature range
Funtion indication
Environmental protection (per IEC529)
Housing material
Sensing face material
Cable Material
Cable Length / Diameter / AWG
BES-RFTA-3010-S-03
BES-RFEA-3010-PS-02
BES-RFEA-3010-NS-02
BES-RFTA-3018-01
BES-RFEA-3018-P-02
BES-RFEA-3018-N-02
2.0...10.0mm Flush / 2.0...8.0mm Non-Flush
0..+50 C
no
IP67
Nickel Plated Brass
ABS + PBT
PVC
3M, 7mm, 12X26AWG
24V DC ± 5%
yes
£ 40mA
max. 50mA per Output
3.2 Hz
0..+50 C
yes
IP67
Nickel Plated Brass
ABS + PBT
PVC
2M, 7mm, 12X26AWG
2.0...18.0mm Non-Flush
0..+50 C
no
IP67
Nickel Plated Brass
ABS + PBT
PVC
1M, 7mm, 12X26AWG
24V DC ± 5%
yes
£ 40mA
max. 50mA per Output
3.2 Hz
0..+50 C
yes
IP67
Nickel Plated Brass
ABS + PBT
PVC
2M, 7mm, 12X26AWG
*These Remotes systems work with mechanical switches also. You can mix and match inductive detectors and mechanical switches.
Basic Remote Sensor System Wiring Schematics · RF/A series
Terminal box for connecting detectors and transmitters are
available as an option. (See Pages 24-25)
Transmitter Output Sensorç•••••èTransmitter Output Sensorç•••••è
[Detector] [Transmitter] [Output Sensor]
RFTA RFEA
5
Remote
Systems
5.11
1-800-543-8390 WWW.BALLUFF.COM
M8 X 1
Flush
1.5mm
0...1.2mm
M12 X 1
Flush
2mm
0...1.6mm
M18 X 1
Flush
5mm
0...4.0mm
M30 X 1
Flush
10mm
0...8.0mm
Passive Detectors RXD
M8 - M30
Sn 1.5 - 10mm
Passive Remote Detector Sensors
Housing Size
Mounting
Rated Sn
Assured Sn
RXD Detector Sensors can only
be used with the passive remote
systems
Transmitter Type
Ambient temperature range
Operating frequency (max.)
Funtion indication
Environmental protection (per IEC529)
Housing material
Sensing face material
Wire Diameter
No. of wires & gauge
Cable Material
Part Number
RXT, RAT
0...+50 C
25 Hz
No
IP67
Stainless Steel
ABS + PBT
4mm
2 X 0.14mm2
PVC
BES-RXD-0801-J-01
RXT, RAT
0...+50 C
25 Hz
No
IP67
Nickel Plated Brass
ABS + PBT
5mm
2 X 0.5mm2
PVC
BES-RXD-1202-J-01
RXT, RAT
0...+50 C
25 Hz
No
IP67
Nickel Plated Brass
ABS + PBT
5mm
2 X 0.5mm2
PVC
BES-RXD-1805-J-01
RXT*, RAT* / RFTA**
0...+50 C
25 Hz
No
IP67
Nickel Plated Brass
ABS + PBT
5mm
2 X 0.5mm2
PVC
BES-RXD-3010-J-01*
BES-RXD-3010M-J-01**
*Can only connect to
RXT, RAT transmitters
(See pages 8-9)
** Can only connect to
RFTA series transmitters
(See page 10)
The RXD remote detectors