www.tracopower.com Page 2
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current (no load) 24 Vin models: 50 mA typ.
48 Vin models: 40 mA typ.
Input current (full load) 24 V in; 1.8 Vout models: 740 mA typ.
24 Vin; 2.5 V out models: 980 mA typ.
24 Vin; 3.3 V out models: 1300 mA typ.
24 Vin; other output models: 1900 mA typ.
48 Vin; 1.8 V out models: 370 mA typ.
48 Vin; 2.5 V out models: 490 mA typ.
48 Vin; 3.3 V out models: 640 mA typ.
48 Vin; other output models: 940 mA typ.
Start-up voltage / 24 Vin models: 17.8 VDC / 15.8 VDC
under voltage shut down 48 Vin models: 36 VDC / 33 VDC
Surge voltage 24 Vin models: 50 V max.
(100 msec. max.) 48 Vin models: 100 V max.
Conducted noise ( Input )ecifications EN 55022 level A, FCC part 15, level A
Output Specifications
V oltage set accuracy ± 1 %
Output voltage adjustment ± 10 %
Regulation – Input variation Vin min. to Vin max. ± 0.2 % max.
– Load variation 10 – 100 % ± 0.5 % max.
Ripple and noise (20 MHz Bandwidth) 12 V out models: 75 mVpk-pk max.
all other models: 50 mVpk-pk max.
Temperature coefficient ± 0.02 % / °C
Output current limitation 110% – 140% Iout max., foldback
Short circuit protection Hiccup mode, indefinite (automatic recovery)
Capacitive load 1.8 V out models / 2.5 V out models: 65’000 µF max. / 33’000 µF max.
3.3 V out models / 5 Vout models: 19’500 µF max. / 10’200 µF max.
12 V out models : 3’300 µF max.
General Specifications
T emperature ranges – Operating – 40 °C ... + 71 °C
– Case temperature + 100 °C max.
– Storage – 55 °C ... + 125 °C
Derating 2.6 %/°C above 60°C
Humidity (non condensing) 95 % rel H max.
Reliability , calculated MTBF (MIL-HDBK-217 E) > 290’000 h @ + 25 °C
Isolation voltage Input/Output 1‘500 VDC
Isolation capacity Input/Output 500 pF typ
Isolation resistance Input/Output > 1’000 Mohm
DC/DC Conver ter
TEN 30 Series 30 Watt