Fluke Industrial/Commercial Thermal Imagers Models: Ti25, Ti10 and Ti9 Technical Data High performance thermal imagers have never been this affordable. This rugged. Or, this easy to use ... until now. Ti25 Ti10 Ti9 Industrial, mechanical, electromechanical and general building maintenance. Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc. Electrical, unbalanced loads, overloaded systems, wiring mistakes or component failure, etc. The perfect tools to add to your problem solving arsenal. Built for tough work environments, these high-performance, fully radiometric imagers are ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others. * The Fluke Ti10 and Ti25 thermal imagers come with enhanced problem detection and analysis capabilities with IR-Fusion(R) Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picturein-picture, or automatic blend visual and thermal images. * Optimized for field use in harsh work environments - Engineered and tested to withstand a 2 m (6.5 ft) drop - Withstands dust and water--tested to an IP54 rating. * Delivers the clear, crisp images needed to find problems fast. * Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD). * Intuitive, three-button menu is easy to use--simply navigate with the push of a thumb. * No need to carry pen and paper--record findings by speaking into the camera. Voice comments are saved along with individual images for future reference (Ti25 only) Fluke. Not just infrared, infrared you can use.(R) Patented Fluke IR-Fusion(R) Technology More than picture in picture Infrared images alone can be difficult to understand, which is why Fluke pioneered IR-Fusion, a revolutionary marriage of visible and infrared images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows to you always know exactly what you're looking at. Not all fusion is created equal Don't be fooled by imitators. No other manufacturer can boast on-camera blending. Compare the images. Only Fluke has mastered the ability to create the industry's only transparent, perfectly blended and aligned visible and infrared images. Fluke Competitor Detailed specifications Temperature Temperature measurement range (not calibrated below -10 C) Temperature measurement accuracy On-screen emissivity correction On-screen reflected background temperature compensation Imaging performance Image capture frequency Detector type Thermal sensitivity (NETD) Visual (visible light) camera Minimum (visible light) focus distance Infrared field of view Spatial resolution (IFOV) Minimum infrared focus distance Focus mechanism Image presentation Palettes Standard Level and span Fast auto toggle between manual and auto modes Fast auto-rescale in manual mode Minimum span (in manual mode) Minimum span (in auto mode) IR-Fusion(R) information Automatically aligned (parallax corrected) visual and IR blending Picture-In-Picture (PIP) Full screen infrared Voice annotation Ti25 Ti10 Ti9 -20 C to +350 C (-4 F to +662 F) -20 C to +250 C (-4 F to +482 F) -20 C to +250 C (-4 F to +482 F) Yes, and in software 5 C or 5 % (at 25 C nominal, whichever is greater) In software only Yes, and in software In software only 2 C or 2 % (at 25 C nominal, whichever is greater) 9 Hz refresh rate 160 X 120 Focal Plane Array, uncooled microbolometer 0.09 C at 30 C target temp. (90 mK) 0.13 C at 30 C target temp. (130 mK) 0.20 C at 30 C target temp. (200 mK) Industrial performance 1.3 megapixels No visible camera 46 cm (approx. 18 in) 23 x 17 2.5 mRad 15 cm (approx. 6 in) Manual, one-handed Smart Focus capability Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, Amber, Hot Metal, Grayscale High Contrast, Grayscale Smooth auto-scaling and manual scaling of level and span Yes -- Yes -- 2.5 C (4.5 F) 5 C (9 F) 5 C (9 F) 10 C (18 F) Yes Three levels of on-screen IR blending displayed in center of LCD (AutoBlend) Three levels of on-screen IR blending displayed on LCD (AutoBlend) 60 seconds maximum recording time per image; reviewable playback on imager 100 % IR displayed in center of LCD No IR-Fusion 100 % IR displayed on LCD -- -- Image capture and data storage The Ti25 allows user to adjust palette, blending, level, span, IR-Fusion(R) mode, emissivity, and reflected background temperature compensation on a captured image before it is stored. Image capture, review, save mechanism Storage medium File formats Export file formats w/SmartView(R) software Memory review 2 Fluke Corporation -- -- One-handed image capture, review, and save capability SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations (when available), or 3000 basic bitmap (.bmp) images transferrable to PC via included multi-format USB card reader Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometic bitmap (.bmp) files BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF Sequential image navigation and review Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers General specifications Operating temperature Storage temperature Relative humidity Display Controls and adjustments -10 C to +50 C (14 F to 122 F) -20 C to +50 C (-4 F to 122 F) without batteries 10 % to 95 % non-condensing 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover User selectable temperature scale (C/F) Language selection Time/Date set Emissivity selection (Ti25 only) Reflected background temperature compensation (Ti25 only) User selectable hot spot and cold spot, and center point on the image (Ti25 only) (other custom markers and shapes in SmartView(R) software) User selectable backlight: "Full Bright" or "Auto" Software SmartView(R) full analysis and reporting software included Batteries Internal rechargeable battery pack (included) Battery life Three to four hours continuous use (assumes 50 % brightness of LCD) Battery charge time 2.5 hours to full charge AC battery charging AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains adapters included. AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006 C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Class B Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6 Shock 25 g, IEC 68-2-29 Drop 2 meter (6.5 feet) Size (H x W x L) 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in) Weight (battery included) 1.2 kg (2.6 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard) Recommended calibration cycle Two-years (assumes normal operation and normal wear) Supported Languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish Ordering information FLK-Ti25 9Hz Thermal Imager FLK-Ti10 9Hz Thermal Imager FLK-Ti9 9Hz Thermal Imager Included Thermal imager, ac power supply/battery charger (including mains adapters); SD memory card; multi-format USB memory card reader for downloading images into your computer; SmartView(R) software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card. Optional accessories TI-CAR-CHARGER Thermal Imager Vehicle Charger TI-VISOR Thermal Imager Visor BOOK-ITP Introduction to Thermography Principles Book TI-TRIPOD Tripod Mounting Base Accessory Fluke. Not just infrared. Infrared you can use.TM Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2009-2011 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 7/2011 3467124G D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation. 3 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLK-TI25 9HZ FLK-TI10 9HZ FLK-TI9 9HZ