Click on Series name for product info on aimtec.com Series AM8TW-Z 8Watt | DC-DC Converter FEATURES: * * * * * Wide 4:1 input range Remote On/Off control High efficiency up to 87% Over Voltage/Overload Protection Soft Start * * * * Operating temperature -40oC to + 85oC Input / Output Isolation 1600 & 3000VDC Continuous short circuit protection Under voltage lockout for 3000VDC models Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM8TW-2403SZ AM8TW-2405SZ AM8TW-2412SZ AM8TW-2415SZ AM8TW-4803SZ AM8TW-4805SZ AM8TW-4812SZ AM8TW-4815SZ 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 3.3 5 12 15 3.3 5 12 15 2000 1500 665 535 2000 1500 665 535 1600 1600 1600 1600 1600 1600 1600 1600 1330 1330 288 200 1330 1330 288 200 80 83 87 87 80 84 87 87 AM8TW-2403SH30Z AM8TW-2405SH30Z AM8TW-2412SH30Z AM8TW-2415SH30Z AM8TW-11003SH30Z AM8TW-11005SH30Z AM8TW-11012SH30Z AM8TW-11015SH30Z 13-70 13-70 13-70 13-70 42-176 42-176 42-176 42-176 3.3 5 12 15 3.3 5 12 15 2000 1500 665 535 2000 1500 665 535 3000 3000 3000 3000 3000 3000 3000 3000 1330 1330 330 220 1330 1330 330 220 83 86 85 86 81 84 84 83 Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) Models Dual output Model AM8TW-2405DZ AM8TW-2412DZ AM8TW-2415DZ AM8TW-4805DZ AM8TW-4812DZ AM8TW-4815DZ 9-36 9-36 9-36 18-75 18-75 18-75 5 12 15 5 12 15 800 335 265 800 335 265 1600 1600 1600 1600 1600 1600 900 133 90 900 133 90 86 86 87 84 87 87 AM8TW-2405DH30Z AM8TW-2412DH30Z AM8TW-2415DH30Z AM8TW-11005DH30Z AM8TW-11012DH30Z AM8TW-11015DH30Z 13-70 13-70 13-70 42-176 42-176 42-176 5 12 15 5 12 15 800 335 265 800 335 265 3000 3000 3000 3000 3000 3000 900 220 100 900 220 100 83 85 86 80 82 83 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 1 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Input Specifications Parameters Voltage range Nominal Typical 24 for 1600VDC models 48 for 1600VDC models 24V or 48V for 3000VDC models 110V Filter Startup time Absolute Maximum Rating For 1600VDC Isolation models For 3000VDC Isolation models 24 for 1600VDC models 48 for 1600VDC models 24V or 48V for 3000VDC models 110V Maximum 9-36 18-75 13-70 42-176 (Pi) Network 20 30 VDC ms -0.7-50 -0.7-100 100 185 100 Peak Input Voltage time On/Off control No Load Input Current Input reflected ripple current Under voltage Lockout (On/Off) Transient recovery time Transient recovery deviation Units VDC ms ON - 3.0 ~ 12VDC (or open) OFF -0~1.2VDC (or short between pin 1 and 2/3), Idle current 5mA, typ. 15 With 12uH inductance 20 24V or 48V for 3000VDC models On - 12V/ Off - 11.7 110V On - 39.5V/ Off - 38 25% load step change, 1A/us 250 3 3.3V output models only 5 mA mAp-p VDC uS % Isolation Specifications Parameters Conditions Tested I/O voltage Tested metal case to Input and Output Resistance 60 sec 60 sec Capacitance Typical Rated Units 1600 & 3000 1000 VDC VDC MOhm >1000 1500 1000 For 1600VDC Isolation models For 3000VDC Isolation models pF Output Specifications Parameters Voltage accuracy Over voltage protection Over load protection Short Circuit protection Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Cross regulation (Dual) Temperature coefficient Ripple & Noise* Conditions Typical Maximum Units 1 1.5 % 48V nom 3000VDC models only Zener Diode Clamp For 1600VDC Isolation models 150 For 3000VDC Isolation models 160 For 3000VDC Isolation models 48V nom 170 Continuous, hiccup, auto recovery HL-LL 1600VDC models 0.2 HL-LL 3000VDC models 0.5 0 - 100% load 0 - 100% load 25% load on one - 100% load on second output 5 0.02 20MHz Bandwidth % % % of Vin 0.5 1 75 % % % %/oC mV p-p *Measured with 1uF ceramic capacitor. General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature www.aimtec.com F 051e R12.I Conditions Typical 100% load 1600VDC models 270 24 & 48V nom 3000VDC models 330 110V 220 Derating above +70 -55 to +125 Maximum KHz oC -40 to +85 oC 105 Tel: +1 514 620 2722 2 of 5 Units oC Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Manual soldering temperature Free air convection 95 Nickel plated Copper 18 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm > 1,000,100 hours(MIL-HDBK-217F , Ground Benign, t=+25oC) 1.5mm from case for 10sec 260 % RH g oC Environment Approval (for 3000V models) Parameters Conditions Cooling & heating EN50155, Class TX According to EN61373, category 1, class B Wave form: Half sine wave Acceleration amplitude: Axis X - 5G, Axis Y and Z - 3G Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) According to EN61373, category 1, class B 5-150Hz 10min per axis & 5h per axis Shock Vibrations Safety Specifications Parameters 1 2 3 9 11 14 16 22 23 Single Remote On/Off -V Input -V Input No Pin N.C. +V Output -V Output +V Input +V Input Dimensions 31.80 (1.25) 22.86 (0.90) 0.50 (0.02) O1.00 (0.04) 1 2 3 11 Bottom View 23 22 2.54 (0.10) 9 16 14 5.08 (0.20) Printed Face All dimensions are typical: millimeters (inches) Pin Diameter: 0.50 0.05 (0.02 0.002) Pin Pitch and length Tolerance: 0.35 (0.014) Case Tolerance: 0.5 (0.02) Stand-off tolerance: 0.1 (0.004) 3.00 (0.12) N.C.: Not Connected Dual Remote On/Off -V Input -V Input Common -V Output +V Output Common +V Input +V Input 15.24 (0.60) Pin 5.01 (0.19) Pin Out Specifications 0.5 (0.02) Standards for 3000VDC models 20.30 (0.80) Standards for 1600VDC models CE, UL (1600VDC models) EN55032 Class A, with recommended circuit IEC61000-4-2, Perf. Criteria A IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria A (external 330uF/100V cap required) IEC61000-4-5, Perf. Criteria A (external 330uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A IEC/EN/UL 60950-1:2001 & IEC/EN/UL 62368-1 EN50155, with external circuit IEC61000-4-2, 8KV/6KV, Perf. Criteria A IEC61000-4-3, Perf. Criteria A IEC61000-4-4, 2KV, Perf. Criteria A, with external circuit IEC61000-4-5, 2KV, Perf. Criteria A, with external circuit IEC61000-4-6, Perf. Criteria A IEC61000-4-8, 10A/m, Perf. Criteria A 10.20 (0.40) Agency Approval www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Derating 70 C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 20 - 40 0 20 40 60 80 85 100 Ambient Temperature C Recommended Circuits for 1600VDC isolated models Conducted Emissions +Vout L C1 +Vin DC/DC Converter C2 Load -Vin -Vout C1 2.2uF, 100V L 12uH C2 2.2uF, 100V Surge/EFT +Vout +Vin DC/DC Converter C1 Load -Vin -Vout C1 330uF, 100V www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8TW-Z 8Watt | DC-DC Converter Recommended Circuits for 3000VDC isolated models +Vin +V output +V input DC/DC Converter C1 -Vin -V input Models AM8TW-24xxxH30z AM8TW-110xxxH30z Load C2 C1 330uF,100V 100uF, 250V -V output C2 100uF, 250V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.I Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only