Rev.03.08.07
bxa40s
3 of 4
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Notes
1Nominal line, at no load.
2Low line to high line at full load.
3Full load to no-load at nominal line.
4For conducted noise operation of the BXA40 to VDE0871, VDE0878 and
EN55022 level B, see BXA40 Design Note 101.
5Reverse voltage protection can be implemented by putting a slow blow fuse on
the positive input rail. Rate the fuse at 200 Vdc,1.5 A for 48 Vdc inputs and 100
V, 4.5 A for 24 Vdc input units.
6The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. Download
BXA40 Design Note 101 which provides detailed thermal calculations and
design-in hints from the Artesyn website.
7Do not exceed a dv/dt rate of 100 V per second at the trim pin input if output
current is less than 0.4% lo max.
8Remote sense is offered as standard on the 2.9 V and 3.3 V products. The
BXA40-24S05J and BXA40-48S05J come with remote sense as an option.
Remote sense design is designated by the suffix ‘-S’ e.g. BXA40-48S05-SMJ (for
units with metric inserts), BXA40-48S05-SJ (for units with imperial inserts). For
models without remote sense option, pin 5 and pin 6 are absent.
9Overvoltage protection is 118% on 3.3 V output model.
10 For 2.9 V output, no short circuit protection above 90 °C baseplate temp.
11 Transient response, 25% to 100% load, 10% for 2.9 V and 3.3 V models.
12 Units with the suffix ‘-M’ at the end of the model number are offered as
standard with metric threaded inserts (M3). To order units with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a PCB and/or fixing
heatsinks.
13 An external filter capacitor is necessary for safe operation of the 24 V input
models. It is also suggested that an external filter capacitor be used on the 48 V
input models. A 4 μF (or greater) film capacitor such as: ITW Paktron Capstick
series, part number 405K100CS4 4 μF/100 V is recommended, if filtering is not
used. See BXA40 Design Note 101.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
INPUT OUTPUT OUTPUT INPUT TYPICAL REGULATION MODEL
VOLTAGE VOLTAGE CURRENT (MAX.) CURRENT (1) EFFICIENCY LINE (2) LOAD (3) NUMBER (12,14,15)
18-36 Vdc 3.3 V 7 A 70 mA 75% 0.3% 1.0% BXA40-24S3V3-SMJ (8)
18-36 Vdc 5 V 8 A 40 mA 81% 0.3% 1.0% BXA40-24S05-MJ (8)
36-75 Vdc 2.9 V 6.9 A 40 mA 77% 0.3% 1.0% BXA40-48S2V9-SMJ (8)
36-75 Vdc 5 V 8.0 A 30 mA 82% 0.3% 1.0% BXA40-48S05-MJ (8)
36-75 Vdc 12 V 3.3 A 30 mA 87% 0.3% 1.0% BXA40-48S12-MJ
PIN CONNECTIONS
PIN NUMBER SINGLE OUTPUT
1 + Input
2 – Input
3 Control
4 No Connection
5 - Sense (8)
6 + Sense (8)
7+ Output
8 Common
9Trim