2
G6K(U)-2F-RF(-S, -T)G6K(U)-2F-RF(-S, -T)
Specifications
■Contact Ratings
Note: This value is for a V.SWR of 1.2 max. at the load.
■
High-frequency Characteristics (See note 3.)
Note: 1. The impedance of the measurement system is 50 Ω.
2. The above values are initial values.
3. Contact your OMRON representative if the Relay will
be used in an application that requires high repeatabil-
ity in high-frequency characteristics for the microload
region. (Such applications include testing and mea-
surement equipment and ATE applications.)
4. These values are for a V.SWR of 1.2 max. at the load.
■Coil Ratings
Single-side Stable Models
G6K-2F-RF(-S, -T)
Single-winding Latching Models
G6KU-2F-RF(-S, -T)
Note: 1. The rated current and coil resistance are measured at
a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil
temperature of 23°C.
3. The maximum voltage is the highest voltage that can
be imposed on the Relay coil instantaneously.
■Characteristics
Note: 1. The above values are initial values.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
3. Values in parentheses are actual values.
4.
The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
Load Resistive load
Rated load 125 VAC, 0.3 A
30 VDC, 1 A
1 GHz, 1 W (See note.)
Rated carry current 1 A
Max. switching voltage 125 VAC or 60 VDC
Max. switching current 1 A
Type
G6K(U)-2F-RF(-S, -T) G6K(U)-2F-RF-T
Item Frequency 1 GHz 3 GHz
Isolation
Between
contacts of
the same
polarity
20 dB min. 18 dB min.
Between
contacts of
different
polarity
30 dB min. 25 dB min.
Insertion loss 0.2 dB max. 0.6 dB max.
V.SWR 1.2 max. 1.4 max.
Maximum carry power
3 W (See note 4.)
Maximum switching power
1 W (See note 4.)
Rated voltage (VDC) 34.551224
Rated current (mA) 33.0 23.2 21.1 9.1 4.6
Coil resistance (Ω)91 194 237 1,315 5,220
Must operate voltage
(V)
80% max. of rated voltage
Must release voltage
(V)
10% min. of rated voltage
Maximum voltage (V) 150% of rated voltage
Power consumption
(mW)
Approx. 100 mW
Rated voltage (VDC) 34.551224
Rated current (mA) 33.0 23.2 21.1 9.1 4.6
Coil resistance (Ω)91 194 237 1,315 5,220
Must operate voltage
(V)
75% max. of rated voltage
Must release voltage
(V)
75% max. of rated voltage
Maximum voltage (V) 150% of rated voltage
Power consumption
(mW)
Approx. 100 mW
Item Single-side stable models Single-winding latching models
G6K-2F-RF(-S, -T) G6KU-2F-RF(-S, -T)
Contact resistance (See note 2.) 100 mΩ max.
Operating (set) time (See note 3.) 3 ms max. (approx. 1.4 ms) 3 ms max. (approx. 1.2 ms)
Release (reset) time (See note 3.) 3 ms max. (approx. 1.3 ms) 3 ms max. (approx. 1.2 ms)
Minimum set/reset pulse time --- 10 ms
Insulation resistance (See note 4.) 1,000 MΩ min. (at 500 VDC)
Dielectric
strength
Between coil and contacts 750 VAC, 50/60 Hz for 1 min
Between contacts of different polarity
750 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity
750 VAC, 50/60 Hz for 1 min
Between ground and coil/contacts 500 VAC, 50/60 Hz for 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude) and
55 to 500 to 55 Hz, 300 m/s2
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) and
55 to 500 to 55 Hz, 200 m/s2
Shock resistance Destruction: 1,000 m/s2
Malfunction: 750 m/s2
Endurance Mechanical: 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
Electrical: 100,000 operations min. (at a switching frequency of 1,800 operations/hour)
Ambient temperature Operating: −40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 0.95 g